Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Rheumatol ; 45(6): 827-834, 2018 06.
Article in English | MEDLINE | ID: mdl-29657153

ABSTRACT

OBJECTIVE: Patients with systemic lupus erythematosus (SLE) frequently undergo repeat testing for antibodies against extractable nuclear antigens (anti-ENA), but it is not known whether this is necessary or cost-effective. This study characterized the frequencies of changes in anti-ENA, anti-dsDNA, and complement C3 and C4 upon repeat testing. METHODS: Chart review was done at one site of 130 patients with SLE enrolled in the 1000 Canadian Faces of Lupus prospective registry with annual antibody and complement testing. We determined the frequency of seroconversion (changes) on the next test and over the entire followup given 1 or multiple consistent results, and the cost to detect these changes. RESULTS: Overall, 89.4% of patients had no changes in anti-ENA screening results from the first available test, 3.3% changed from negative to positive, and 7.3% from positive to negative. Following a single anti-ENA test, 3.9% of negative tests changed to positive and 4.2% of positive changed to negative on the next test. After multiple consistent tests, the frequencies of changes progressively declined. No changes from the first test were observed in anti-dsDNA, C3, and C4 in 60.8%, 83.3%, and 75.4% of patients, respectively. After 2 consistent anti-ENA tests, the cost to detect 1 change was above US$2000. CONCLUSION: Anti-ENA results change infrequently, especially following 1 or more negative tests. The high cost and lack of evidence that changes affect management suggest that repeating anti-ENA tests routinely is unnecessary. Anti-dsDNA and complements change more frequently after an abnormal result, but less after a normal value.


Subject(s)
Antibodies, Antinuclear/analysis , Antigens, Nuclear/immunology , Complement C3/analysis , Complement C4/analysis , Lupus Erythematosus, Systemic/blood , Adult , Female , Humans , Lupus Erythematosus, Systemic/immunology , Male , Middle Aged , Prospective Studies , Young Adult
2.
Phys Chem Chem Phys ; 12(46): 15282-90, 2010 Dec 14.
Article in English | MEDLINE | ID: mdl-20835485

ABSTRACT

Herein we report the one-pot electrodeposition of copper indium gallium diselenide, CuIn(1-x)Ga(x)Se(2) (CIGS), thin films as the p-type semiconductor in an ionic liquid medium consisting of choline chloride/urea eutectic mixture known as Reline. The thin films were characterized by scanning electron microscopy with energy dispersive X-ray analysis, transmission electron microscopy, X-ray photoelectron spectroscopy, Raman microspectroscopy, and UV-visible spectroscopy. Based on the results of the characterizations, the electrochemical bath recipe was optimized to obtain stoichiometric CIGS films with x between 0.2 and 0.4. The chemical activity and photoreactivity of the optimized CIGS films were found to be uniform using scanning electrochemical microscopy and scanning photoelectrochemical microscopy. Low-cost stoichiometric CIGS thin films in one-pot were successfully fabricated.

SELECTION OF CITATIONS
SEARCH DETAIL
...