Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
1.
EFORT Open Rev ; 7(3): 188-199, 2022 Mar 17.
Article in English | MEDLINE | ID: mdl-35298414

ABSTRACT

Prosthetic hip-associated cobalt toxicity (PHACT) is caused by elevated blood cobalt concentrations after hip arthroplasty. The aim of this study is to determine which symptoms are reported most frequently and in what type of bearing. We also try to determine the blood level of cobalt concentrations associated with toxicological symptoms. A systematic review was conducted on the 10th of July according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A methodological quality assessment (risk of bias (RoB)) was performed. Primary outcomes were the reported symptoms of cobalt toxicity and the level of cobalt concentrations in blood. These levels were associated with toxicological symptoms. A total of 7645 references were found of which 67 relevant reports describing 79 patients. The two most used bearings in which PHACT was described were metal-on-metal (MoM) bearings (38 cases) and revised (fractured) ceramic-on-ceramic (CoC) bearings where the former ceramic head was replaced by a metal head (32 cases). Of all reported symptoms, most were seen in the neurological system, of which 24% were in the sensory system and 19.3% were in central/peripheral system, followed by the cardiovascular (22.1%) system. The mean cobalt concentration for MoM-bearings was 123.7 ± 96.8 ppb and 1078.2 ± 1267.5 ppb for the revised fractured CoC-bearings. We recommend not to use a metal-based articulation in the revision of a fractured CoC bearing and suggest close follow-up with yearly blood cobalt concentration controls in patients with a MoM bearing or a revised fractured CoC bearing. Level of Evidence: Level V, systematic review.

2.
Arch Orthop Trauma Surg ; 142(12): 4025-4032, 2022 Dec.
Article in English | MEDLINE | ID: mdl-34846589

ABSTRACT

BACKGROUND: Preliminary results of metal-on-metal (MoM) hip arthroplasty were satisfactory, but since 2004 data showed high failure rates. National joint replacement registries are multi-centre databases comprised of thousands of subjects and implants which allow for identifying variables predictive of implant failure. The aim of the current study was to estimate re-revision rates after revision of a primary MoM hip arthroplasty in the Dutch Arthroplasty Register (LROI) and to assess potential predictor variables of re-revision of these MoM hip arthroplasties. METHODS: Eligible procedures were those with a revision for any reason except infection, after an initial primary surgery with a hip resurfacing (HRA) or large-head MoM (LH-MoM) total hip arthroplasty (THA). The probability of re-revision for both types of MoM hip arthroplasty over time was estimated using the cumulative incidence function taking mortality as a competing risk into account. A proportional sub-distribution hazards regression model was used to assess potential predictor variables of re-revision of these MoM hip arthroplasties. RESULTS: A total of 3476 records of revised implants were included, of which 873 (25.2%) were MoM implants. Over the course of follow-up, 101 (11.5%) MoM implants were re-revised. During follow-up 36 (4.3%) patients who received a MoM-implant at primary arthroplasty and a revision afterwards had died. The regression model showed that for primary MoM implants a MoM articulation after revision (HR 2.48; 95% CI 1.53-4.03, p < 0.001), femoral-only revisions (HR 3.20; 95% CI 2.06-4.99, p < 0.001) and periprosthetic fractures (HR 1.98; 95% CI 1.03-3.82, p = 0.042) as reason for the first revision were statistically significant risk factors for re-revision. CONCLUSION: Both types of large-head MoM hip arthroplasties have shown high revision and re-revision rates; risk factors were identified. The outcome of this study can be helpful in managing expectations of patients and orthopaedic surgeons.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Humans , Metal-on-Metal Joint Prostheses/adverse effects , Hip Prosthesis/adverse effects , Prosthesis Failure , Prosthesis Design , Reoperation/methods , Arthroplasty, Replacement, Hip/adverse effects , Metals , Risk Factors , Registries , Treatment Outcome
3.
Expert Rev Pharmacoecon Outcomes Res ; 21(4): 579-593, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33472442

ABSTRACT

Background: This study aims to present an overview and critical appraisal of all previous studies comparing costs and outcomes of the different modes of fixation in total hip arthroplasty (THA). A secondary aim is to provide conclusions regarding the most cost-effective mode of implant fixation per gender and age-specific population in THA, based on high quality studies.Methods: A systematic search was conducted to identify cost-effectiveness analyses (CEAs) comparing different modes of implant fixation in THA. Analysis of results was done with solely CEAs that had a high methodological quality.Results: A total of 12 relevant studies were identified and presented, of which 5 were considered to have the methodological rigor for inclusion in the analysis of results. These studies found that either cemented or hybrid fixation was the most cost-effective implant fixation mode for most age- and gender-specific subgroups.Conclusion: Currently available well performed CEAs generally support the use of cemented and hybrid fixation for all age-groups relevant for THA and both genders. However, these findings were mainly based on a single database and depended on assumptions made in the studies' methodology. Issues discussed in this paper have to be considered and future work is needed.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Bone Cements/chemistry , Age Factors , Arthroplasty, Replacement, Hip/economics , Cost-Benefit Analysis , Female , Humans , Male , Sex Factors
4.
Bone Joint J ; 99-B(4): 421-431, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28385929

ABSTRACT

AIMS: Our aim was to prepare a systematic review and meta-analysis to compare the outcomes of cemented and cementless hemiarthroplasty of the hip, in elderly patients with a fracture of the femoral neck, to investigate the mortality, complications, length of stay in hospital, blood loss, operating time and functional results. MATERIALS AND METHODS: A systematic review and meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines on randomised controlled trials (RCTs), studying current generation designs of stem only. The synthesis of results was done of pooled data, with a fixed effects or random effects model, based on heterogeneity. RESULTS: A total of five RCTs including 950 patients (950 hips) were included. Cementless stems were found to be associated with more complications compared with cemented stems (odds ratio (OR) 1.61, 95% confidence interval (CI) 1.12 to 2.31, p = 0.01), especially implant-related complications (OR 3.15, 95% CI 1.55 to 6.41, p = 0.002). The operating time was shorter for cementless stems (weighted mean difference -9.96 mins, 95%CI -12.93 to -6.98, p < 0.001). The data on functional outcomes could not be pooled. There was no statistically significant difference for any other outcome between the two methods of fixation. CONCLUSION: In hemiarthroplasty of the hip using current generation stems, cemented stems result in fewer implant-related complications and similar mortality compared with cementless stems. Cite this article: Bone Joint J 2017;99-B:421-31.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Cementation/methods , Femoral Neck Fractures/surgery , Hemiarthroplasty/methods , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Blood Loss, Surgical , Bone Cements , Hemiarthroplasty/adverse effects , Humans , Length of Stay/statistics & numerical data , Prosthesis Design , Randomized Controlled Trials as Topic , Reoperation/statistics & numerical data
5.
Knee Surg Sports Traumatol Arthrosc ; 25(11): 3366-3371, 2017 Nov.
Article in English | MEDLINE | ID: mdl-27492381

ABSTRACT

PURPOSE AND HYPOTHESIS: The purpose of this study was to 'objectively' measure improvement of physical activity with the use of an activity monitor between patients who followed an enhanced recovery- or outpatient surgery pathway after total knee arthroplasty (TKA). It was hypothesized that both pathways will have comparable physical activity after TKA at 6-week follow-up. METHODS: This prospective observational comparative case study was designed to investigate activity parameters (e.g. physical activity, number of steps, sit-stand transfers) of two different pathways after 6 weeks with the use of a non-invasive triaxial accelerometer activity monitor. This study included 20 patients with a mean age of 65.5 years (SD 6.1) undergoing TKA who were allocated to follow one of the two pathways: enhanced recovery (n = 10) or outpatient surgery (n = 10). Patients were monitored for 4 days pre-, 4 days during and 4 days after 5 weeks postoperatively. Patient-reported outcome measures (PROMs) and range of knee motion were obtained pre- and 6 weeks postoperatively. RESULTS: The activity parameters recovered steeply during the first 4 postoperative days and continued to improve within both pathways (n.s.). Preoperative and during the first 4 days and 5 weeks postoperative, activity parameters were comparable (n.s.) between both pathways but did not reach preoperative levels of physical activity and range of motion (n.s.). PROMs improved within each pathway, and no difference between both pathways was observed (n.s.). CONCLUSIONS: This study demonstrates that the early physical activity parameters of patients after TKA, following the outpatient surgery pathway, were similar to patients who followed the standard enhanced recovery pathway. The activity monitor is an added value for a more detailed and objective analysis of the physical performance in patients after TKA. LEVEL OF EVIDENCE: III.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/rehabilitation , Exercise , Osteoarthritis, Knee/surgery , Accelerometry , Aged , Ambulatory Surgical Procedures , Case-Control Studies , Clinical Protocols , Critical Pathways , Female , Humans , Male , Middle Aged , Prospective Studies , Range of Motion, Articular , Recovery of Function
6.
Clin Biomech (Bristol, Avon) ; 32: 171-9, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26706048

ABSTRACT

BACKGROUND: Functional outcome assessment after total hip arthroplasty often involves subjective patient-reported outcome measures whereas analysis of gait is more objective. The study's aims were to compare subjective and objective functional outcomes after total hip arthroplasty between patients with low and high self-reported levels of pre-operative physical function. METHODS: Patients undergoing total hip arthroplasty (n=36; m/f=18/18; mean age=63.9; SD=9.8 years; BMI=26.3; SD=3.5) were divided into a low and high function subgroup, and prospective measures of WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index) function score and gait were compared at baseline and 3 and 12 months post-operatively. FINDINGS: WOMAC function scores significantly improved in both low and high function subgroups at 3 months post-operatively whereas gait parameters only improved in patients with a low pre-operative function. Between 3 and 12 months post-operatively, WOMAC function scores had not significantly further improved whereas several gait parameters significantly improved in the low function group. WOMAC function scores and gait parameters were only moderately correlated (Spearman's r=0.33-0.51). INTERPRETATION: In a cohort of patients undergoing total hip arthroplasty, pre-operative differences in mean WOMAC function scores and gait parameters between low and high function subgroups disappeared by 3 months post-operatively. Gait parameters only improved significantly during the first 3 post-operative months in patients with a low pre-operative function, highlighting the importance of investigating relative changes rather than the absolute changes and the need to consider patients with high and low functions separately.


Subject(s)
Arthroplasty, Replacement, Hip , Gait , Aged , Female , Humans , Male , Middle Aged , Patient Outcome Assessment , Patient Satisfaction , Postoperative Period , Prospective Studies , Self Report , Treatment Outcome , Walking
7.
Med Eng Phys ; 38(3): 225-31, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26711470

ABSTRACT

An inertial measurement unit (IMU) allows kinematic evaluation of human motion with fewer operational constraints than a gold standard optoelectronic motion capture (MOCAP) system. The study's aim was to compare IMU and MOCAP measurements of dynamic pelvic orientation angles during different activities of daily life (ADL): gait, sit-to-stand (STS) transfers and block step-up (BS) transfers. A single IMU was attached onto the lower back in seventeen healthy participants (8F/9 M, age 19-31 years; BMI < 25) and optical skin markers were attached onto anatomical pelvic landmarks for MOCAP measurements. Comparisons between IMU and MOCAP by Bland-Altman plots demonstrated that measurements were between 2SD of the absolute difference and Pearson's correlation coefficients were between 0.85 and 0.94. Frontal plane pelvic angle estimations achieved a RMSE in the range of [2.7°-4.5°] and sagittal plane measurements achieved a RMSE in the range of [2.7°-8.9°] which were both lowest in gait. Waveform peak detection times demonstrated ICCs between 0.96 and 1.00. These results are in accordance to other studies comparing IMU and MOCAP measurements with different applications and suggest that an IMU is a valid tool to measure dynamic pelvic angles during various activities of daily life which could be applied to monitor rehabilitation in a wide variety of musculoskeletal disorders.


Subject(s)
Electrical Equipment and Supplies , Gait , Light , Mechanical Phenomena , Pelvis/physiology , Posture , Adult , Biomechanical Phenomena , Female , Humans , Male , Young Adult
8.
Open Biomed Eng J ; 9: 157-63, 2015.
Article in English | MEDLINE | ID: mdl-26312077

ABSTRACT

BACKGROUND: It is important to assess physical activity objectively during daily life circumstances, to understand the association between physical activity and diseases and to determine the effectiveness of interventions. Accelerometer-based physical activity monitoring seems a promising method and could potentially capture all four FITT (i.e. Frequency, Intensity, Time, Type) components of physical activity considered by the World Health Organization (WHO). AIM: To assess the four FITT components of physical activity with an accelerometer during daily life circumstances and compare with self-reported levels of physical activity in patients with knee osteoarthritis (OA) and a healthy control group. METHODS: Patients (n=30) with end-stage knee OA and age-matched healthy subjects (n=30) were measured. An ambulant tri-axial accelerometer was placed onto the lateral side of the upper leg. Physical activity was measured during four consecutive days. Using algorithm-based peak detection methods in Matlab, parameters covering the four FITT components were assessed. Self-reported physical activity was assessed using the Short questionnaire to assess health enhancing physical activity (SQUASH). RESULTS: Knee OA patients demonstrated fewer walking bouts (154 ±79 versus 215 ±65 resp.; p=0.002), step counts (4402 ±2960 steps/day versus 6943 ±2581 steps/day; p=0.001) and sit-to-stand (STS) transfers (37 ±14 versus 44 ±12; p=0.031) compared to controls. Knee OA patients demonstrated more time sitting (65 ±15% versus 57 ±10% resp.; p=0.029), less time walking (8 ±4% versus 11 ±4% resp.; p=0.014) and lower walking cadence (87 ±11steps/min versus 99 ± 8steps/min resp.; p<0.001). Accelerometer-based parameters of physical activity were moderately-strong (Pearsons's r= 0.28-0.49) correlated to self-reported SQUASH scores. CONCLUSION: A single ambulant accelerometer-based physical activity monitor feasibly captures the four FITT components of physical activity and provides more insight into the actual physical activity behavior and limitations of knee OA patients in their daily life.

9.
Knee ; 22(6): 618-23, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26032657

ABSTRACT

BACKGROUND: Outcome assessment of total knee arthroplasty (TKA) by subjective patient reported outcome measures (PROMs) may not fully capture the functional (dis-)abilities of relevance. Objective performance-based outcome measures could provide distinct information. An ambulant inertial measurement unit (IMU) allows kinematic assessment of physical performance and could potentially be used for routine follow-up. AIM: To investigate the responsiveness of IMU measures in patients following TKA and compare outcomes with conventional PROMs. METHODS: Patients with end stage knee OA (n=20, m/f=7/13; age=67.4 standard deviation 7.7 years) were measured preoperatively and one year postoperatively. IMU measures were derived during gait, sit-stand transfers and block step-up transfers. PROMs were assessed by using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Knee Society Score (KSS). Responsiveness was calculated by the effect size, correlations were calculated with Spearman's rho correlation coefficient. RESULTS: One year after TKA, patients performed significantly better at gait, sit-to-stand transfers and block step-up transfers. Measures of time and kinematic IMU measures demonstrated significant improvements postoperatively for each performance-based test. The largest improvement was found in block step-up transfers (effect size=0.56-1.20). WOMAC function score and KSS function score demonstrated moderate correlations (Spearman's rho=0.45-0.74) with some of the physical performance-based measures pre- and postoperatively. CONCLUSION: To characterize the changes in physical function after TKA, PROMs could be supplemented by performance-based measures, assessing function during different activities and allowing kinematic characterization with an ambulant IMU.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Gait/physiology , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Patient Outcome Assessment , Patient Satisfaction , Quality of Life , Aged , Biomechanical Phenomena , Female , Follow-Up Studies , Humans , Knee Joint/physiopathology , Male , Osteoarthritis, Knee/physiopathology , Prospective Studies , Surveys and Questionnaires
10.
Oper Orthop Traumatol ; 26(2): 156-61, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24699925

ABSTRACT

OBJECTIVE: Biological repair of femoral bone loss using bone impaction grafting. Reconstruction of the centre of rotation of the hip using a cemented stem, the size and offset of which are at the discretion of the surgeon. INDICATIONS: Femoral implant loosening with bone loss. CONTRAINDICATIONS: Infection, neurological disorders, noncompliant patient. SURGICAL TECHNIQUE: Extraction of the loose femoral implant, cortical reconstruction using meshes if required, impaction bone grafting with special instruments, cement fixation of a polished tapered stem. POSTOPERATIVE MANAGEMENT: Individualized period of bed rest and limited weight bearing. RESULTS: Impaction bone grafting and a cemented polished stem were used to perform 33 femoral reconstructions. After a mean follow-up of 15 years, no femoral reconstruction had to be revised. One unrecognized intraoperative fracture healed after nonsurgical treatment, three postoperative femoral fractures healed after plate fixation with the stem left in situ. The average Harris Hip Score improved from 49 prior to surgery to 85 points thereafter. Kaplan-Meier analysis with femoral revision for any reason as the end point showed a survival rate of 100 %.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Bone Transplantation/methods , Cementation/methods , Femoral Fractures/surgery , Hip Prosthesis/adverse effects , Periprosthetic Fractures/surgery , Arthroplasty, Replacement, Hip/instrumentation , Combined Modality Therapy/methods , Female , Humans , Male , Middle Aged , Reoperation/instrumentation , Reoperation/methods , Treatment Outcome
11.
Physiol Meas ; 35(4): 677-86, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24622109

ABSTRACT

Shoulder-related dysfunction is the second most common musculoskeletal disorder and is an increasing burden on health-care systems. Commonly used clinical questionnaires suffer from subjectivity, pain dominance and a ceiling effect. Objective functional measurement has been identified as a relevant issue in clinical rehabilitation. Inertia based motion analysis (IMA) is a new generation of objective outcome assessment tool; it can produce objective movement parameters while being fast, cheap and easy to operate. In this prospective study, an inertial sensor comprising a three-dimensional accelerometer and gyroscope is attached at the humerus to measure shoulder movements during two motion tasks in patients with subacromial impingement syndrome at baseline and at five-year after treatment. One hundred healthy subjects served as healthy reference database and 15 patients were measured pre- and post-treatment. IMA was better able to detect improvement in shoulder movements compared to the clinical questionnaires (Disability of Arm, Shoulder and Hand (DASH) and Simple Shoulder Test (SST); p < 0.05) and was hardly correlated with the clinical questionnaires (Pearson R = 0.39). It may therefore add an objective functional dimension to outcome assessment. The fast assessment (t < 5 min) of a simple motion test makes it suitable for routine clinical follow-up.


Subject(s)
Motion , Physiology/instrumentation , Shoulder Impingement Syndrome/diagnosis , Adult , Biomechanical Phenomena , Demography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Shoulder Impingement Syndrome/physiopathology , Surveys and Questionnaires
12.
Physiol Meas ; 35(2): 167-76, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24398361

ABSTRACT

Shoulder-related dysfunction is the second most common musculoskeletal disorder and is responsible for an increasing burden on health-care systems. Commonly used clinical outcome scores suffer from subjectivity, pain dominance and a ceiling effect. Objective functional measurement has been identified as a relevant issue in clinical rehabilitation. In recognition of this goal simple techniques for routine clinical application have been investigated with some success. Inertia based motion analysis (IMA) is a new generation of objective outcome assessment tool; it can produce objective movement parameters while being fast, cheap and easy to operate. This study investigates if a simple IMA shoulder test is suitable as a functional outcome measure for routine clinical follow-up. We measured 100 healthy subjects and 50 patients with confirmed unilateral shoulder pathology. Two motion tasks were performed on both shoulders and two simple motion parameters based on angular rate and acceleration were calculated. Patients were also assessed by the disability of arm, shoulder and hand (DASH) and the simple shoulder test. IMA produced high intra- (ICC = 0.94) and inter-assessor reliability (ICC = 0.90). Asymmetry was >3 times higher in patients than in healthy controls (p < 0.01). Healthy and pathological subjects could be distinguished with high diagnostic sensitivity (>84.0%) and specificity (>81.0%). There was a weak correlation between the IMA shoulder score and the clinical questionnaires (Pearson R < 0.25), as it may add an objective functional dimension to outcome assessment. The fast assessment (t < 5 min) of a simple motion task makes it workable for routine clinical follow-up. The IMA shoulder test adds objective information on functional capacity to the clinical scores and may help the physician in his decision-making, follow-up of treatment, effect of training and possibly lead to the development of new therapeutic interventions.


Subject(s)
Physical Examination/methods , Shoulder/physiology , Adult , Aged , Biomechanical Phenomena , Female , Humans , Male , Middle Aged , Movement , Observer Variation , Shoulder/physiopathology , Surveys and Questionnaires , Young Adult
13.
Gait Posture ; 39(1): 513-7, 2014.
Article in English | MEDLINE | ID: mdl-24119777

ABSTRACT

Dynamic imbalance caused by external perturbations to gait can successfully be counteracted by adequate recovery responses. The current study investigated how the recovery response is moderated by age, walking speed, muscle strength and speed of information processing. The gait pattern of 50 young and 45 elderly subjects was repeatedly perturbed at 20% and 80% of the first half of the swing phase using the Timed Rapid impact Perturbation (TRiP) set-up. Recovery responses were identified using 2D cameras. Muscular factors (dynamometer) and speed of information processing parameters (computer-based reaction time task) were determined. The stronger, faster reacting and faster walking young subjects recovered more often by an elevating strategy than elderly subjects. Twenty three per cent of the differences in recovery responses were explained by a combination of walking speed (B=-13.85), reaction time (B=-0.82), maximum extension strength (B=0.01) and rate of extension moment development (B=0.19). The recovery response that subjects employed when gait was perturbed by the TRiP set-up was modified by several factors; the individual contribution of walking speed, muscle strength and speed of information processing was small. Insight into remaining modifying factors is needed to assist and optimise fall prevention programmes.


Subject(s)
Aging/physiology , Cognition/physiology , Gait/physiology , Muscle Strength/physiology , Postural Balance/physiology , Accidental Falls , Adult , Aged , Biomechanical Phenomena , Female , Humans , Linear Models , Male , Middle Aged , Muscle, Skeletal/physiology , Reaction Time , Risk Factors , Young Adult
14.
Osteoporos Int ; 24(1): 151-62, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22638708

ABSTRACT

UNLABELLED: Hip fracture patients can benefit from nutritional supplementation during their recovery. Up to now, cost-effectiveness evaluation of nutritional intervention in these patients has not been performed. Costs of nutritional intervention are relatively low as compared with medical costs. Cost-effectiveness evaluation shows that nutritional intervention is likely to be cost-effective. INTRODUCTION: Previous research on the effect of nutritional intervention on clinical outcome in hip fracture patients yielded contradictory results. Cost-effectiveness of nutritional intervention in these patients remains unknown. The aim of this study was to evaluate cost-effectiveness of nutritional intervention in elderly subjects after hip fracture from a societal perspective. METHODS: Open-label, multi-centre randomized controlled trial investigating cost-effectiveness of intensive nutritional intervention comprising regular dietetic counseling and oral nutritional supplementation for 3 months postoperatively. Patients allocated to the control group received care as usual. Costs, weight and quality of life were measured at baseline and at 3 and 6 months postoperatively. Incremental cost-effectiveness ratios (ICERs) were calculated for weight at 3 months and quality adjusted life years (QALYs) at 6 months postoperatively. RESULTS: Of 152 patients enrolled, 73 were randomized to the intervention group and 79 to the control group. Mean costs of the nutritional intervention was 613 Euro. Total costs and subcategories of costs were not significantly different between both groups. Based on bootstrapping of ICERs, the nutritional intervention was likely to be cost-effective for weight as outcome over the 3-month intervention period, regardless of nutritional status at baseline. With QALYs as outcome, the probability for the nutritional intervention being cost-effective was relatively low, except in subjects aged below 75 years. CONCLUSION: Intensive nutritional intervention in elderly hip fracture patients is likely to be cost-effective for weight but not for QALYs. Future cost-effectiveness studies should incorporate outcome measures appropriate for elderly patients, such as functional limitations and other relevant outcome parameters for elderly.


Subject(s)
Dietary Supplements/economics , Elder Nutritional Physiological Phenomena/physiology , Hip Fractures/rehabilitation , Postoperative Care/economics , Aged , Aged, 80 and over , Body Weight , Cost-Benefit Analysis , Counseling/economics , Counseling/methods , Female , Fracture Fixation/rehabilitation , Health Care Costs/statistics & numerical data , Hip Fractures/economics , Humans , Male , Middle Aged , Netherlands , Nutritional Support/economics , Nutritional Support/methods , Postoperative Care/methods , Quality-Adjusted Life Years
15.
Physiotherapy ; 98(4): 320-4, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23122438

ABSTRACT

OBJECTIVE: To quantify the effects of subject characteristics on gait parameters using acceleration-based gait analysis. DESIGN: Cross-sectional study with a single group cohort. SETTING: Hospital setting. PARTICIPANTS: One hundred and twenty healthy subjects (six age decade groups of 10 men and 10 women) performed a 20-m walking test. METHODS: Basic gait parameters (e.g. speed) and other clinically relevant parameters (e.g. step time asymmetry) were assessed during a 20-m walking test using a tri-axial accelerometer, attached at the level of the sacrum. Subject characteristics were recorded. RESULTS: Between 34% and 51% of the variability in gait parameters was explained by age, height and gender. Subject characteristics contributed less to the variance in step time asymmetry (R(2)=0.02), gait irregularity (R(2)=0.07) and vertical displacement of the centre of mass (R(2)=0.17). Relationships identified were comparable with previous studies (e.g. faster walking speed in men, younger and taller subjects). CONCLUSIONS: Age, height and gender are determinants of basic gait parameters, while their influence on gait irregularity and step time asymmetry is minimal. This indicates that gait is variable between subjects, showing the relevance of correcting gait for subject characteristics. This study describes preliminary work to build a database of gait parameters in healthy participants, describing the effects of age, gender and height. Further studies to extend this database with patients would provide further relevance to clinical practice.


Subject(s)
Accelerometry/instrumentation , Body Height/physiology , Body Weight/physiology , Gait Disorders, Neurologic , Gait/physiology , Physical Therapy Modalities/instrumentation , Accelerometry/methods , Accelerometry/standards , Adult , Age Factors , Aged , Aged, 80 and over , Cohort Studies , Cross-Sectional Studies , Female , Gait Disorders, Neurologic/diagnosis , Gait Disorders, Neurologic/physiopathology , Gait Disorders, Neurologic/rehabilitation , Humans , Male , Middle Aged , Physical Therapy Modalities/standards , Predictive Value of Tests , Regression Analysis , Sex Factors , Treatment Outcome , Walking/physiology , Young Adult
16.
Physiol Meas ; 33(11): 1947-58, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23110821

ABSTRACT

Patients undergoing total knee replacement for end stage knee osteoarthritis (OA) become increasingly younger and more demanding. Consequently, outcome assessment tools need to evolve toward objective performance-based measures. We applied a novel approach toward ambulatory biomechanical assessment of physical function using a single inertial sensor located at the pelvis to derive various motion parameters during activities of daily living. We investigated the potential of a clinically feasible battery of tests to define relevant parameters of physical function. We compared preoperative measures of end stage knee OA patients to healthy subjects. Our results show that measures of time yield the highest discriminative capacity to differentiate between groups. Additionally we found disease-dependent and task-specific alterations of movement for inertial sensor-derived motion parameters with good discriminative capacity. The inertial sensor's output quantities seem to capture another clinically relevant dimension of physical function that is supplementary to time. This study demonstrates the potential of inertial sensor-based motion analysis and provides a standardized test feasible for a routine clinical application in the longitudinal follow-up.


Subject(s)
Accelerometry/instrumentation , Gait/physiology , Osteoarthritis, Knee/diagnosis , Osteoarthritis, Knee/physiopathology , Posture/physiology , Aged , Area Under Curve , Case-Control Studies , Feasibility Studies , Female , Humans , Male , Middle Aged
17.
Gait Posture ; 36(2): 296-300, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22512847

ABSTRACT

This study investigated whether the Tinetti scale, as a subjective measure for fall risk, is associated with objectively measured gait characteristics. It is studied whether gait parameters are different for groups that are stratified for fall risk using the Tinetti scale. Moreover, the discriminative power of gait parameters to classify elderly according to the Tinetti scale is investigated. Gait of 50 elderly with a Tinneti>24 and 50 elderly with a Tinetti≤24 was analyzed using acceleration-based gait analysis. Validated algorithms were used to derive spatio-temporal gait parameters, harmonic ratio, inter-stride amplitude variability and root mean square (RMS) from the accelerometer data. Clear differences in gait were found between the groups. All gait parameters correlated with the Tinetti scale (r-range: 0.20-0.73). Only walking speed, step length and RMS showed moderate to strong correlations and high discriminative power to classify elderly according to the Tinetti scale. It is concluded that subtle gait changes that have previously been related to fall risk are not captured by the subjective assessment. It is therefore worthwhile to include objective gait assessment in fall risk screening.


Subject(s)
Accidental Falls , Gait/physiology , Walking/physiology , Aged , Female , Humans , Male , Postural Balance , Risk Factors
18.
Article in English | MEDLINE | ID: mdl-21096022

ABSTRACT

Falling is a serious health problem for many elderly. To investigate whether the higher fall incidence in elderly is due to a higher probability of experiencing near falls in daily life, it is necessary to evaluate the stumble incidence of elderly in daily life. Accelerometers are already frequently used for in vivo activity monitoring. The current study investigates whether an ambulant and unobtrusive accelerometer can identify stumbles from treadmill walking using a wavelet based detection approach. Seventy nine healthy subjects walked on a treadmill with a triaxial accelerometer attached at the level of the sacrum. Stumbles were induced using a specially designed braking system (The TRiP). The TRiP evoked 30 stumbles at different phases of the swing phase. A wavelet-based detection algorithm is used to isolate the stumbles from treadmill walking, with a specificity of 99.9% and a sensitivity of 98.4%.


Subject(s)
Accidental Falls/prevention & control , Monitoring, Ambulatory/methods , Acceleration , Adult , Aged , False Negative Reactions , False Positive Reactions , Humans , Middle Aged , Signal Processing, Computer-Assisted , Time Factors , Walking/physiology , Young Adult
19.
Eur Radiol ; 20(3): 764-8, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20157818

ABSTRACT

Juxta-articular myxoma (JAM) is a relatively rare variant of myxoma that occurs in the vicinity of large joints. It is composed of fibroblast-like cells that produce an excessive amount of glycosaminoglycans rich in hyaluronic acid. The peak incidence is between the 3rd and 5th decades of life. In this report we describe an extremely rare case of JAM in the knee of a 5-year-old child. The clinical presentation, radiological features and histopathologic findings are described, and the relevant literature is reviewed.


Subject(s)
Joint Diseases/pathology , Knee Joint/pathology , Myxoma/pathology , Soft Tissue Neoplasms/pathology , Adolescent , Humans , Male
20.
Gait Posture ; 30(2): 192-6, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19477649

ABSTRACT

Accelerometers enable us to analyse gait outside conventional gait laboratories. Before these devices can be used in large scale studies and in clinical settings a thorough evaluation of their performance in different populations is required. The aim of this study was to present an acceleration-based reference database for healthy gait. The repeatability and inter-observer reliability of acceleration-based gait analysis was investigated. The sensitivity was tested on different age groups and the effect of gender was studied. A comprehensive set of gait parameters (i.e. cadence, speed, asymmetry and irregularity) were studied in 60 women and 60 men. Basic gait parameters showed high repeatability (VC(cadence) 1.51%, ICC(cadence) 0.996) and inter-observer reliability (ICC(cadence) 0.916), while asymmetry and irregularity showed lower repeatability (VC(asym) 47.88%, ICC(asym) 0.787) and inter-observer reliability (ICC(asym) 0.449). The effects of age and gender on gait parameters were found to be consistent with those reported in studies using other methodologies. These findings and the advantages of the device support the application of AGA for routine clinical use and in daily life.


Subject(s)
Gait/physiology , Acceleration , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Monitoring, Ambulatory , Observer Variation , Reference Values , Reproducibility of Results , Sensitivity and Specificity , Sex Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...