Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Comput Assist Radiol Surg ; 19(2): 297-302, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37924438

ABSTRACT

PURPOSE: Resection of pediatric osteosarcoma in the extremities with soft tissue involvement presents surgical challenges due to difficult visualization and palpation of the tumor. Therefore, an adequate image-guided surgery (IGS) system is required for more accurate tumor resection. The use of a 3D model in combination with intraoperative tracked ultrasound (iUS) may enhance surgical decision making. This study evaluates the clinical feasibility of iUS as a surgical tool using a porcine cadaver model. METHODS: First, a 3D model of the porcine lower limb was created based on preoperative scans. Second, the bone surface of the tibia was automatically detected with an iUS by a sweep on the skin. The bone surface of the preoperative 3D model was then matched with the bone surface detected by the iUS. Ten artificial targets were used to calculate the target registration error (TRE). Intraoperative performance of iUS IGS was evaluated by six pediatric surgeons and two pediatric oncologic orthopedists. Finally, user experience was assessed with a post-procedural questionnaire. RESULTS: Eight registration procedures were performed with a mean TRE of 6.78 ± 1.33 mm. The surgeons agreed about the willingness for clinical implementation in their current clinical practice. They mentioned the additional clinical value of iUS in combination with the 3D model for the localization of the soft tissue components of the tumor. The concept of the proposed IGS system is considered feasible by the clinical panel, but the large TRE and degree of automation need to be addressed in further work. CONCLUSION: The participating pediatric surgeons and orthopedists were convinced of the clinical value of the interaction between the iUS and the 3D model. Further research is required to improve the surgical accuracy and degree of automation of iUS-based registration systems for the surgical management of pediatric osteosarcoma.


Subject(s)
Bone Neoplasms , Osteosarcoma , Surgery, Computer-Assisted , Humans , Child , Swine , Animals , Imaging, Three-Dimensional/methods , Surgery, Computer-Assisted/methods , Bone Neoplasms/diagnostic imaging , Bone Neoplasms/surgery , Osteosarcoma/diagnostic imaging , Osteosarcoma/surgery , Cadaver
2.
Int J Comput Assist Radiol Surg ; 18(9): 1725-1734, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37227572

ABSTRACT

PURPOSE: Surgical navigation techniques can guide surgeons in localizing pelvic-abdominal malignancies. For abdominal navigation, accurate patient registration is crucial and is generally performed using an intra-operative cone-beam CT (CBCT). However, this method causes 15-min surgical preparation workflow interruption and radiation exposure, and more importantly, it cannot be repeated during surgery to compensate for large patient movement. As an alternative, the accuracy and feasibility of tracked ultrasound (US) registration are assessed in this patient study. METHODS: Patients scheduled for surgical navigation during laparotomy of pelvic-abdominal malignancies were prospectively included. In the operating room, two percutaneous tracked US scans of the pelvic bone were acquired: one in supine and one in Trendelenburg patient position. Postoperatively, the bone surface was semiautomatically segmented from US images and registered to the bone surface on the preoperative CT scan. The US registration accuracy was computed using the CBCT registration as a reference and acquisition times were compared. Additionally, both US measurements were compared to quantify the registration error caused by patient movement into Trendelenburg. RESULTS: In total, 18 patients were included and analyzed. US registration resulted in a mean surface registration error of 1.2 ± 0.2 mm and a mean target registration error of 3.3 ± 1.4 mm. US acquisitions were 4 × faster than the CBCT scans (two-sample t-test P < 0.05) and could even be performed during standard patient preparation before skin incision. Patient repositioning in Trendelenburg caused a mean target registration error of 7.7 ± 3.3 mm, mainly in cranial direction. CONCLUSION: US registration based on the pelvic bone is accurate, fast and feasible for surgical navigation. Further optimization of the bone segmentation algorithm will allow for real-time registration in the clinical workflow. In the end, this would allow intra-operative US registration to correct for large patient movement. TRIAL REGISTRATION: This study is registered in ClinicalTrials.gov (NCT05637359).


Subject(s)
Abdominal Neoplasms , Pelvic Neoplasms , Surgery, Computer-Assisted , Humans , Feasibility Studies , Ultrasonography , Tomography, X-Ray Computed/methods , Pelvic Neoplasms/diagnostic imaging , Pelvic Neoplasms/surgery , Surgery, Computer-Assisted/methods , Imaging, Three-Dimensional
SELECTION OF CITATIONS
SEARCH DETAIL
...