Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Thorac Dis ; 11(8): 3270-3275, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31559029

ABSTRACT

BACKGROUND: Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is a frequently performed procedure. Suction is utilized during this procedure and may occasionally result in the collection of aspirated material, the diagnostic utility of which is uncertain. This study aims to determine the contents of the suction syringe aspirate and its diagnostic value. METHODS: The suction syringe aspirate was pooled in a container and sent for analysis. We retrospectively reviewed the cytological outcomes of these specimens in comparison to the diagnosis determined by EBUS-TBNA between 2015-2018. The primary outcome was the percent agreement between the diagnostic material found in the suction syringe aspirate, and the final diagnosis established by EBUS-TBNA. RESULTS: Forty-four patients were included. Percent agreement was calculated as the percent in which the suction syringe aspirate diagnosis agreed with the EBUS-TBNA diagnosis. The percent agreement of any diagnosis was 90.9% (95% CI: 78.7-97.2%). Two of the 44 diagnoses (4.5%) were established based solely on the suction syringe aspirate, both cases of granulomatous inflammation. CONCLUSIONS: Our results suggest that material collected in the suction syringe has a very high percent agreement with the final diagnosis established by EBUS-TBNA. Furthermore, the suction syringe aspirate may represent the sole diagnostic material in nearly 5% of cases. Given the additional diagnostic material in the suction syringe aspirate, it is reasonable to pool the aspirate with the primary specimen in an effort to enrich the overall diagnostic specimen. This practice may improve the likelihood that the specimen will be sufficient for additional molecular analysis, although further study is necessary. Care must be taken when more than one needle is involved to ensure that a new suction syringe is also used to avoid inadvertent upstaging by specimen contamination.

2.
J Bronchology Interv Pulmonol ; 24(2): 170-173, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28323734

ABSTRACT

Fluoroscopy-guided transbronchial forceps biopsy has a low diagnostic yield in patients with radiographic suspicion of interstitial lung disease. Cryobiopsy has a higher diagnostic yield likely due to preserved lung architecture and larger biopsies; however, there is an increased risk of major airway bleeding and pneumothorax. Simultaneous use of endobronchial balloon blocker allows for containment of bleeding after cryobiopsy to the affected lobe. In the current article we describe use of radial ultrasound in identification of a target lung parenchyma without a major blood vessel adjacent to distal bronchi. After fluoroscopic marking of the selected airway a 3 second cryobiopsy was performed after localization of cryoprobe. Simultaneous use of radial ultrasound and fluoroscopy can possibly decrease bleeding complication associated with cryobiopsy in patients with suspected interstitial lung disease.


Subject(s)
Bronchoscopy/adverse effects , Cryosurgery/adverse effects , Lung Diseases, Interstitial/diagnosis , Aged , Aged, 80 and over , Female , Fluoroscopy/instrumentation , Humans , Male , Middle Aged , Retrospective Studies , Ultrasonography/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...