1.
Hypertension ; 62(3): 579-84, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23897073

ABSTRACT

The introduction of automated oscillometric blood pressure monitors was the basis for today's widespread use of blood pressure self-measurement. However, in atrial fibrillation, there is a controversial debate on the use of oscillometry because there is a high variability of heart rate and stroke volume. To date, the accuracy of oscillometric blood pressure monitoring in atrial fibrillation has only been investigated using auscultatory sphygmomanometry as reference method, which may be biased by arrhythmia as well. We performed a cross-sectional study in 102 patients (52 sinus rhythm, 50 atrial fibrillation) assessing the accuracy of an automated and validated oscillometric upper arm (M5 Professional, Omron) and wrist device (R5 Professional, Omron) to invasively assessed arterial pressure. Blood pressure values were calculated as the mean of 3 consecutive measurements. Systolic and diastolic blood pressure did not significantly differ in patients with sinus rhythm and atrial fibrillation, independent of the method of measurement (P>0.05 each). The within-subject variability of the oscillometric measurements was higher in patients with atrial fibrillation compared with sinus rhythm (P<0.01 each). The biases of systolic and diastolic blood pressure, however, did not significantly differ in presence or absence of atrial fibrillation in Bland-Altmann analysis (P>0.05 each). In conclusion, atrial fibrillation did not significantly affect the accuracy of oscillometric measurements, if 3 repeated measurements were performed.


Subject(s)
Atrial Fibrillation/physiopathology , Blood Pressure Determination/instrumentation , Blood Pressure Monitors , Blood Pressure/physiology , Oscillometry , Adult , Aged , Aged, 80 and over , Blood Pressure Determination/methods , Cross-Sectional Studies , Female , Humans , Male , Middle Aged
3.
Int J Antimicrob Agents ; 36(6): 545-8, 2010 Dec.
Article in English | MEDLINE | ID: mdl-20863668

ABSTRACT

Vancomycin (VAN) dosing requires adjustment to renal function, which is often estimated using the Cockcroft-Gault formula; however, its precision is poor in Intensive Care Unit (ICU) patients. VAN clearance (CL(Van)) during continuous infusion was prospectively determined in 25 ICU patients [14 male, 11 female; age range 31-82 years; body mass index (BMI) 16.5-41.5 kg/m²; Acute Physiology and Chronic Health Evaluation (APACHE) II score at admission 8-36; creatinine clearance 25-195 mL/min] and its correlation with measured creatinine clearance (CL(Crea)), estimated creatinine clearance using the Cockcroft-Gault formula (CL(CG)) and estimated glomerular filtration rate according to Hoek's formula based on serum cystatin C (GFR(Hoek)) was investigated. The correlation between CL(Van) and CL(Crea) was very good (r²=0.88), but it was rather poor with CL(CG) (r² = 0.37) and was acceptable with GFR(Hoek) (r² = 0.70). For VAN dose adjustments in ICU patients, determination of cystatin C may be an interesting and practical alternative to measured CL(Crea), whereas the Cockcroft-Gault formula should be used with caution.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/pharmacokinetics , Creatinine/blood , Cystatin C/blood , Serum/chemistry , Vancomycin/administration & dosage , Vancomycin/pharmacokinetics , Adult , Aged , Aged, 80 and over , Female , Humans , Infusions, Intravenous , Intensive Care Units , Male , Metabolic Clearance Rate , Middle Aged , Statistics as Topic