Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 18(5): e0285391, 2023.
Article in English | MEDLINE | ID: mdl-37146058

ABSTRACT

PURPOSE: Recently, new MRI systems working at magnetic field below 10 mT (Very and Ultra Low Field regime) have been developed, showing improved T1-contrast in projected 2D maps (i.e. images without slice selection). Moving from projected 2D to 3D maps is not trivial due to the low SNR of such devices. This work aimed to demonstrate the ability and the sensitivity of a VLF-MRI scanner operating at 8.9 mT in quantitatively obtaining 3D longitudinal relaxation rate (R1) maps and distinguishing between voxels intensities. We used phantoms consisting of vessels doped with different Gadolinium (Gd)-based Contrast Agent (CA) concentrations, providing a set of various R1 values. As CA, we used a commercial compound (MultiHance®, gadobenate dimeglumine) routinely used in clinical MRI. METHODS: 3D R1 maps and T1-weighted MR images were analysed to identify each vessel. R1 maps were further processed by an automatic clustering analysis to evaluate the sensitivity at the single-voxel level. Results obtained at 8.9 mT were compared with commercial scanners operating at 0.2 T, 1.5 T, and 3 T. RESULTS: VLF R1 maps offered a higher sensitivity in distinguishing the different CA concentrations and an improved contrast compared to higher fields. Moreover, the high sensitivity of 3D quantitative VLF-MRI allowed an effective clustering of the 3D map values, assessing their reliability at the single voxel level. Conversely, in all fields, T1-weighted images were less reliable, even at higher CA concentrations. CONCLUSION: In summary, with few excitations and an isotropic voxel size of 3 mm, VLF-MRI 3D quantitative mapping showed a sensitivity better than 2.7 s-1 corresponding to a concentration difference of 0.17 mM of MultiHance in copper sulfate doped water, and improved contrast compared to higher fields. Based on these results, future studies should characterize R1 contrast at VLF, also with other CA, in the living tissues.


Subject(s)
Magnetic Resonance Imaging , Organometallic Compounds , Reproducibility of Results , Magnetic Resonance Imaging/methods , Contrast Media
2.
J Magn Reson ; 305: 138-145, 2019 08.
Article in English | MEDLINE | ID: mdl-31280186

ABSTRACT

Magnetic resonance imaging in ultra-low fields is often limited by mediocre signal-to-noise ratio hindering a higher resolution. Overhauser dynamic nuclear polarisation (O-DNP) using nitroxide radicals has been an efficient solution for enhancing the thermal nuclear polarisation. However, the concurrence of positive and negative polarisation enhancements arises in ultra-low fields resulting in a significantly reduced net enhancement, making O-DNP far less attractive. Here, we address this issue by applying circularly polarised RF. O-DNP with circularly polarised RF renders a considerably improved enhancement factor of around 150,000 at 1.2 µT. A birdcage coil was adopted into an ultra-low field MRI system to generate the circularly polarised RF field homogeneously over a large volume. We acquired an MR image of a nitroxide radical solution with an average in-plane resolution of 1 mm. De-noising through compressive sensing further improved the image quality.

3.
J Magn Reson ; 274: 89-94, 2017 01.
Article in English | MEDLINE | ID: mdl-27889653

ABSTRACT

Superconducting quantum interference devices are widely used in basic and clinical biomagnetic measurements such as low-field magnetic resonance imaging and magnetoencephalography primarily because they exhibit high sensitivity at low frequencies and have a wide bandwidth. The main disadvantage of these devices is that they require cryogenic coolants, which are rather expensive and not easily available. Meanwhile, with the advances in laser technology in the past few years, optically pumped atomic magnetometers (OPAMs) have been shown to be a good alternative as they can have adequate noise levels and are several millimeters in size, which makes them significantly easier to use. In this study, we used an OPAM module operating at a Larmor frequency of 5kHz to acquire NMR and MRI signals. This study presents these initial results as well as our initial attempts at imaging using this OPAM module. In addition, we have designed a liquid-cooled pre-polarizing coil that reduces the measurement time significantly.

4.
Magn Reson Imaging ; 31(2): 171-7, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22898690

ABSTRACT

Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as well, thus enabling higher image resolutions. On the other hand, MRI is possible also at ultra-low magnetic fields, as was shown by different groups. The goal of our development was to reach a Larmor frequency range of the low-field MRI system corresponding to the frequency range of human brain activities ranging from near zero-frequency (near-DC) to over 1 kHz. Here, first 2D MRI images of phantoms taken at Larmor frequencies of 100 Hz and 731 Hz will be shown and discussed. These frequencies are examples of brain activity triggered by electrostimulation of the median nerve. The method will allow the magnetic fields of the brain currents to influence the magnetic resonance image, and thus lead to a direct functional imaging modality of neuronal currents.


Subject(s)
Magnetic Resonance Imaging/methods , Algorithms , Brain/pathology , Computer Simulation , Equipment Design , Fourier Analysis , Humans , Image Processing, Computer-Assisted , Magnetic Fields , Neurons/pathology , Phantoms, Imaging , Photons , Signal-To-Noise Ratio , Time Factors
5.
Magn Reson Imaging ; 29(10): 1365-73, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21907519

ABSTRACT

A number of different methods have been developed in order to detect the spreading of neuronal currents by means of noninvasive imaging techniques. However, all of these are subjected to limitations in the temporal or spatial resolution. A new approach of neuronal current detection is based on the use of low-field nuclear magnetic resonance (LF-NMR) that records brain activity directly. In the following, we describe a phantom study in order to assess the feasibility of neuronal current detection using LF-NMR. In addition to that, necessary preliminary subject studies examining somatosensory evoked neuronal currents are presented. During the phantom study, the influences of two different neuronal time signals on (1)H-NMR signals were observed. The measurements were carried out by using a head phantom with an integrated current dipole to simulate neuronal activity. Two LF-NMR methods based on a DC and an AC (resonant) mechanism were utilized to study the feasibility of detecting both types of magnetic brain signals. Measurements were made inside an extremely magnetically shielded room by using a superconducting quantum interference device magnetometer system. The measurement principles were validated applying currents of higher intensity than those typical of the neuronal currents. Through stepwise reduction of the amplitude of the current dipole strength, the resolution limits of the two measuring procedures were found. The results indicate that it is necessary to improve the signal-to-noise ratio of the measurement system by at least a factor of 38 in order to detect typical human neuronal activity directly by means of LF-NMR. In addition to that, ways of achieving this factor are discussed.


Subject(s)
Brain Mapping/methods , Brain/physiology , Evoked Potentials, Somatosensory/physiology , Magnetic Resonance Spectroscopy/methods , Brain Mapping/instrumentation , Humans , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
6.
Biomed Tech (Berl) ; 56(2): 91-7, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21446889

ABSTRACT

Magnetoencephalography measurements of somatosensory evoked brain activity taken inside an extremely magnetically shielded room are reported. The massive low frequency shielding in combination with a high sampling rate enabled the simultaneous observation of AC and near-DC effects. Neuronal activation was achieved by repetitive electrostimulation of the right median nerve above motor threshold using repetition rates from 3 Hz to 12 Hz. Stimulation sequences lasted for 10 s and were interspersed with periods of rest of equal length. The recorded magnetic fields, inferred for the N20m and a sustained near-DC component, revealed mainly dipolar patterns with mutually rotated orientations with angles of rotation of 30° and 75°. At the start of the stimulation we observed a fast rise within 100 ms in the evoked magnetic near-DC fields for which a maximum equivalent current dipole strength of 65 nAm was obtained. The sustained fields decayed by a factor of ∼4 to a lower DC-level B(γ) with a time constant τ of order of seconds. For 12 Hz repetition rate B(γ) was decreased. We suggest that the sustained neuronal activity evoked by repetitive electrostimulation could provide a suitable scheme to realize the direct detection of DC effects of neuronal currents via low field magnetic resonance.


Subject(s)
Algorithms , Brain/physiology , Diagnosis, Computer-Assisted/methods , Evoked Potentials, Somatosensory/physiology , Magnetoencephalography/methods , Adult , Female , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...