Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
1.
J Clin Med ; 11(21)2022 Nov 04.
Article in English | MEDLINE | ID: mdl-36362774

ABSTRACT

Background: As a preventive procedure, minimizing periprocedural risk is crucially important during left atrial appendage closure (LAAC). Methods: We included consecutive patients receiving LAAC at nine centres and assessed the relationship between baseline characteristics and the acute procedural outcome. Major procedural complications were defined as all complications requiring immediate invasive intervention or causing irreversible damage. Logistic regression was performed and included age and left-ventricular function. Furthermore, the association between acute complications and long-term outcomes was evaluated. Results: A total of 405 consecutive patients with a median age of 75 years (37% female) were included. 47% had a history of stroke. Median CHA2DS2-VASc score was 4 (interquartile range, 3−5) and the median HAS-BLED score was 3 (2−4). Major procedural complications occurred in 7% of cases. Low haemoglobin (OR 0.8, 95% CI 0.65−0.99 per g/dL, p = 0.040) and end-stage kidney disease (OR 13.0, CI 2.5−68.5, p = 0.002) remained significant in multivariate analysis. Anaemia (haemoglobin < 12 and < 13 g/dL in female and male patients) increased the risk of complications 2.2-fold. Conclusions: The major complication rate was low in this high-risk patient population undergoing LAAC. End-stage kidney disease and low baseline haemoglobin were independently associated with a higher major complication rate.

2.
J Clin Med ; 10(19)2021 Sep 26.
Article in English | MEDLINE | ID: mdl-34640411

ABSTRACT

(1) Background: The exact anatomic localization of the accessory pathway (AP) in patients with Wolff-Parkinson-White (WPW) syndrome still relies on an invasive electrophysiologic study, which has its own inherent risks. Determining the AP localization using a 12-lead ECG circumvents this risk but is of limited diagnostic accuracy. We developed and validated an artificial intelligence-based algorithm (location of accessory pathway artificial intelligence (locAP AI)) using a neural network to identify the AP location in WPW syndrome patients based on the delta-wave polarity in the 12-lead ECG. (2) Methods: The study included 357 consecutive WPW syndrome patients who underwent successful catheter ablation at our institution. Delta-wave polarity was assessed by four independent electrophysiologists, unaware of the site of successful catheter ablation. LocAP AI was trained and internally validated in 357 patients to identify the correct AP location among 14 possible locations. The AP location was also determined using three established tree-based, ECG-based algorithms (Arruda, Milstein, and Fitzpatrick), which provide limited resolutions of 10, 5, and 8 AP locations, respectively. (3) Results: LocAP AI identified the correct AP location with an accuracy of 85.7% (95% CI 79.6-90.5, p < 0.0001). The algorithms by Arruda, Milstein, and Fitzpatrick yielded a predictive accuracy of 53.2%, 65.6%, and 44.7%, respectively. At comparable resolutions, the locAP AI achieved a predictive accuracy of 95.0%, 94.9%, and 95.6%, respectively (p < 0.001 for differences). (4) Conclusions: Our AI-based algorithm provided excellent accuracy in predicting the correct AP location. Remarkably, this accuracy is achieved at an even higher resolution of possible anatomical locations compared to established tree-based algorithms.

3.
JACC Cardiovasc Imaging ; 14(11): 2199-2208, 2021 11.
Article in English | MEDLINE | ID: mdl-34147453

ABSTRACT

OBJECTIVES: This study sought to evaluate preablation computed tomography angiography (CTA) for atrial and epicardial features to predict atrial fibrillation (AF) recurrence after ablation. BACKGROUND: Structural atrial remodeling is a process associated with occurrence or persistence of AF. Different anatomical imaging features have been proposed to influence atrial remodeling both negatively and positively as substrate for AF. METHODS: Patients with nonvalvular AF underwent cardiac CTA before pulmonary vein isolation at 2 high-volume centers. Left atrial (LA) and right atrial volumes, LA wall thickness (LAWT), and epicardial adipose tissue volume and attenuation were evaluated. Additional subanalyses of electroanatomical maps were made. Follow-up was performed for at least 12 months, including subanalysis of repeated cardiac CTA studies. Interrater variability was assessed. RESULTS: Of 732 patients, 270 (36.9%) had AF recurrence after a mean of 7 months. CT analysis revealed larger indexed LA volume (47.3 mL/m2 vs 43.6 mL/m2; P = 0.0001) and higher mean anterior (1.91 mm vs 1.65 mm; P < 0.0001) and posterior (1.61 mm vs 1.39 mm; P = 0.001) LAWT in patients with AF recurrence. Epicardial adipose tissue volume in patients with AF recurrence was higher (144.5 mm³ vs 128.5 mm³; P < 0.0001) and further progressed significantly in a subset of 85 patients after 2 years (+11.8 mm2 vs -3.5 mm2; P = 0.041). Attenuation levels were lower, indicating a higher lipid component associated with AF recurrence (-69.1 HU vs -67.5 HU; P = 0.001). A total of 103 atrial voltage maps were highly predictive of AF recurrence and showed good discriminatory power for patients with low voltage >50% and LAWT (1.55 ± 0.5 mm vs 1.81 ± 0.6 mm; P = 0.032). Net reclassification improvement (NRI) showed a significant incremental benefit (NRI = 0.279; P < 0.0001) when adding LAWT to established risk models. CONCLUSIONS: Atrial wall thickness, epicardial fat volume, and attenuation are associated with AF recurrence in patients undergoing ablation therapy.


Subject(s)
Atrial Fibrillation , Atrial Remodeling , Catheter Ablation , Heart Atria , Humans , Predictive Value of Tests , Recurrence , Treatment Outcome , Ventricular Remodeling
4.
J Cardiovasc Dev Dis ; 8(4)2021 Apr 07.
Article in English | MEDLINE | ID: mdl-33917180

ABSTRACT

BACKGROUND: Leadless transcatheter pacemaker systems (TPS) have become a valuable alternative to transvenous pacemakers in selected indications. With the steadily increasing amount of TPS implantations performed worldwide, reports of periprocedural complications are likewise increasingly found in the literature but are still underreported. CASE PRESENTATION: We report a case of a 75 year old male undergoing TPS implantation due to cardioinhibitory vasovagal syncope. The implantation was primarily uneventful; adequate pacing parameters and fixation of the device were achieved. Unfortunately, dislocation of the leadless pacemaker occurred at the end of the procedure and the device embolized into a primary side branch of the right pulmonary artery. Endovascular retrieval was performed by using a single snare technique without any further complications. CONCLUSIONS: Although challenging, endovascular recovery of embolized TPS from the pulmonary artery is feasible and may be successfully accomplished by experienced implanters.

5.
Am J Cardiol ; 139: 97-104, 2021 01 15.
Article in English | MEDLINE | ID: mdl-33002463

ABSTRACT

The role of central sleep apnea (CSA) in pacing-induced cardiomyopathy (PICM) remains speculative. In a prospective trial entitled UPGRADE, the presence of CSA was assessed by single-night polysomnography (PSG) in 54 PICM patients within 1 month after left ventricular lead implantation (with biventricular stimulation still not activated). CSA was diagnosed in half of patients (n = 27). Patients with moderate or severe CSA were randomized to cardiac resynchronization therapy (CRT) versus right ventricular pacing (RVP) in a double-blinded cross-over design and re-scheduled for a follow-up PSG within 3 to 5 months. After crossing-over of stimulation mode another PSG was conducted 3 to 5 months later. CRT led to a significant increase in left ventricular ejection fraction and significant reduction in left ventricular end systolic volumes and N-terminal pro brain natriuretic peptide plasma levels, whereas no significant effects were observed with ongoing RVP. CSA was significantly improved after 3.9 (3.2 to 4.4) months of CRT: apnea-hypopnea index decreased from 39.1 (32.1 to 54.0) events per hour at baseline to 22.2/h (10.9 to 36.7) by CRT (p <0.001). Central apnea index decreased from 27.1/h (17.7 to 36.1) at baseline to 6.8/h (1.1 to 14.4) after CRT activation (p <0.001). Ongoing RVP yielded only a minor improvement in apnea-hypopnea index and central apnea index. Pre-existent CSA did not affect structural response rate and had no impact on mid-term follow-up (median 2.8 years). In conclusion, CSA is highly prevalent in patients with PICM. CRT upgrading significantly improves CSA leading to a similar outcome in PICM patients without pre-existent CSA.


Subject(s)
Cardiac Pacing, Artificial/adverse effects , Cardiomyopathies/etiology , Heart Failure/therapy , Sleep Apnea, Central/complications , Stroke Volume/physiology , Ventricular Function, Left/physiology , Aged , Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Echocardiography , Female , Follow-Up Studies , Heart Failure/complications , Heart Failure/physiopathology , Humans , Male , Middle Aged , Polysomnography , Prospective Studies , Sleep Apnea, Central/physiopathology
6.
J Clin Med ; 9(12)2020 Dec 05.
Article in English | MEDLINE | ID: mdl-33291376

ABSTRACT

BACKGROUND: New markers for stroke risk stratification in patients with atrial fibrillation (AF) are on demand. Hence, we aimed to investigate the association of left atrial appendage (LAA) and left atrium (LA) morphological parameters in patients with cardio-embolic (CE) stroke due to AF in comparison to controls without stroke. METHODS: A retrospective analysis of cardiac computed tomography angiography (CTA) examinations performed between 2006 and 2017 for clinical indications in 158 patients (median age 65 (54-73) years, 48.7% females) was conducted: 56 patients with CE stroke were compared to 102 controls not differing in gender, body mass index (BMI) and CHA2DS2-VASc score. RESULTS: On multivariable regression analysis adjusted for CHA2DS2-VASc score and LA diameter CE stroke was independently associated with the following parameters: windsock LAA type (OR 2.55; CI: 1.04-6.26, p = 0.041), a greater lobe number (OR 1.54; CI: 1.13-2.10, p = 0.006), a greater LAA ostium area (OR 1.88; CI: 1.38-2.55, p < 0.001) and a greater left atrium wall thickness (LAWT) in the middle and right part, measured along the anterior LA wall in the axial plane (respectively, OR 1.94; CI: 1.26-3.0, p = 0.003 and OR 1.57; CI: 1.07-2.31, p = 0.021). CONCLUSIONS: The windsock LAA type, a greater LAA lobe number, a larger LAA ostium and a greater LAWT are associated with CE stroke. These CTA parameters could improve risk stratification for thromboembolic stroke.

7.
Data Brief ; 33: 106461, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33294502

ABSTRACT

This article contains supplemental data to the publication "Central Sleep Apnea and Pacing-Induced Cardiomyopathy" [1], which was the most recent publication of the "UPGRADE" study. It provides in-depth analysis of the effects of cardiac resynchronisation therapy (CRT) in patients suffering from pacing-induced cardiomyopathy (PICM) on cardiac remodeling as well as functional cardiac parameters in comparison to continuous right ventricular pacing (RVP). Furthermore, it also covers additional data on several sleep parameters, which were not presented in the main article including the index for obstructive sleep apnea (OSA), the index for mixed sleep apnea and the oxygen saturation measurements during polysomnography. Further, Kaplan-Meier curves are presented for major adverse cardiac events (MACE) and overall mortality by severity of sleep apnea. Generally, the "UGRADE" study was a single-center prospective double-blinded randomized controlled trial lasting from 2014 to 2020. The methodology included a cross-over design giving the possibility to detect differences while CRT was activated and while continuous RVP was applied. The presented data should aid clinicians in daily practice as upgrading to CRT is not limited to improvement in cardiac parameters, but also modifies sleep apnea in patients with PICM, a generally sparsely studied entity of heart failure.

9.
Clin Res Cardiol ; 109(9): 1107-1113, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32002630

ABSTRACT

BACKGROUND: A brain-heart interaction has been proposed in Takotsubo syndrome (TTS). Structural changes in the limbic system and hypoconnectivity between certain brain areas in the chronic phase of the disease have been reported, but little is known concerning functional neuroimaging in the acute phase. We hypothesized anatomical and functional changes in the central nervous system and investigated whole-brain volumetric and functional connectivity alterations in the acute phase TTS patients compared to controls. METHODS: Anatomical and resting-state functional magnetic resonance imaging were performed in postmenopausal females: thirteen in the acute TTS phase and thirteen healthy controls without evidence of coronary artery disease. Voxel-based morphometry and graph theoretical analysis were applied to identify anatomical and functional differences between patients and controls. RESULTS: Significantly lower gray matter volumes were found in TTS patients in the right middle frontal gyrus (p = 0.004) and right subcallosal cortex (p = 0.009) compared to healthy controls. When lower threshold was applied, volumetric changes were noted in the right insular cortex (p = 0.0113), the right paracingulate cortex (p = 0.012), left amygdala (p = 0.018), left central opercular cortex (p = 0.017), right (p = 0.013) and left thalamus (p = 0.017), and left cerebral cortex (p = 0.017). Graph analysis revealed significantly (p < 0.01) lower functional connectivity in TTS patients compared to healthy controls, particularly in the connections originating from the right insular cortex, temporal lobes, and precuneus. CONCLUSION: In the acute phase of TTS volumetric changes in frontal regions and the central autonomic network (i.e. insula, anterior cingulate cortex, and amygdala) were noted. In particular, the right insula, associated with sympathetic autonomic tone, had both volumetric and functional changes.


Subject(s)
Cerebral Cortex/diagnostic imaging , Functional Neuroimaging/methods , Magnetic Resonance Imaging/methods , Takotsubo Cardiomyopathy/diagnostic imaging , Aged , Autonomic Nervous System/diagnostic imaging , Brain/diagnostic imaging , Case-Control Studies , Female , Humans , Middle Aged , Postmenopause , Takotsubo Cardiomyopathy/physiopathology
10.
Data Brief ; 29: 105111, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31993469

ABSTRACT

Hereby, the supplemental data of the research article "Long-Term Prognostic Value of High-Sensitivity Troponin T added to N-Terminal Pro Brain Natriuretic Peptide Plasma Levels before Valve Replacement for Severe Aortic Stenosis" are presented [1]. It offers enhanced input on the predictive value of these biomarkers considering the influence of the presence of concomitant coronary artery disease (CAD) in various severities as well as an additional cox proportional hazard model on cardiovascular mortality. Furthermore, the receiver operating characteristic (ROC) curves are shown as figures. The material described increases therefore the understanding of the predictive value of these already routinely available biomarkers and reduces the risk of potential bias due to possible confounding factors. It also underlines the urge for a multi-factorial approach in diagnostics to detect the optimal point for referral to valve replacement other than just symptomatic status, an observed reduction in left ventricular ejection fraction or the presence of CAD with the necessity for coronary artery bypass grafting (CABG) [2]. The data of the 3595 patients were gathered retrospectively at a consortium of four university hospital centers in Austria and combined with prospectively collected data on cardiovascular and all-cause mortality.

12.
Am J Cardiol ; 124(12): 1932-1939, 2019 12 15.
Article in English | MEDLINE | ID: mdl-31699359

ABSTRACT

Natriuretic peptide plasma levels help to manage patients with severe aortic stenosis (AS). The role of troponin plasma levels in this patient cohort remains speculative. A consortium of 4 university hospital centers in Austria analyzed retrospectively 3,595 patients admitted for valve replacement because of severe AS since 2007. The aim was to compare the additive preprocedural value of high-sensitivity troponin T (hsTnT) to N-terminal pro brain natriuretic peptide (NT-proBNP) plasma levels in predicting postoperative long-term survival in a large cohort undergoing either surgical (57.8%) or transcatheter (42.2%) aortic valve replacement. During a median follow-up of 2.93 (1.91 to 4.92) years, 919 patients (25.6%) died, in them 556 (15.5%) due to cardiovascular causes. Both normal hsTnT (<14 ng/l) and NT-proBNP (within age- and sex-corrected normal range) plasma levels were found in 481 patients (14.3%, group 1). Normal hsTnT but elevated NT-proBNP plasma levels were found in 748 patients (22.3%, group 2). Elevated hsTnT but normal NT-proBNP plasma levels were found in 258 patients (7.7%, group 3). Both elevated hsTnT and elevated NT-proBNP plasma levels were found in 1,869 patients (55.7%, group 4). Using Log Rank tests for comparison there was a highly significant difference in both cardiovascular mortality (p <0.0001) and all-cause mortality (p <0.0001). All-cause mortality rates after 1, 3, and 5 years were 2.1%, 5.4%, 7.7% in group 1; 4.0%, 7.5%, 11.5% in group 2; 5.8%, 8.9%, 14.0% in group 3; and 12.3%, 22.6%, 28.4% in group 4. In conclusion, hsTnT adds additional impact to NT-proBNP as a routinely available biomarker for risk stratification concerning postoperative survival in patients with severe AS admitted for valve replacement. The present study supports the concept to integrate hsTnT plasma levels in the management of severe AS.


Subject(s)
Aortic Valve Stenosis/blood , Aortic Valve Stenosis/mortality , Heart Valve Prosthesis Implantation/mortality , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Troponin T/blood , Aged , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Austria , Biomarkers/blood , Cohort Studies , Echocardiography, Doppler/methods , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Hospitals, University , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Preoperative Care/methods , Prognosis , Retrospective Studies , Risk Assessment , Sensitivity and Specificity , Severity of Illness Index , Survival Rate , Time Factors , Treatment Outcome
13.
PLoS One ; 14(9): e0222269, 2019.
Article in English | MEDLINE | ID: mdl-31498840

ABSTRACT

OBJECTIVES: To evaluate the long-term performance of the SonRtip atrial lead. BACKGROUND: To optimize atrioventricular and interventricular timing and thereby potentially improving cardiac resynchronization therapy (CRT) responder rates, a lead integrated technology and a cardioverter/defibrillator-based algorithm measuring peak endocardial acceleration have been introduced. Long-term performance of the atrial lead (SonRtip PS55D, Sorin/MicroPort CRM, Italy) embedded with such a sensor has not been reported so far. METHODS: Between 2012 and 2018, 143 patients underwent implantation of the SonRtip atrial lead in four Austrian medical centers. Conventional bipolar atrial leads implanted during the same period in 526 patients receiving CRT were used as control cohort. RESULTS: Among 669 patients included in the study, 10 (1.5%) showed increased atrial pacing thresholds and/or decreased atrial sensing amplitudes and/or sudden increase in atrial lead impedance (above 3000 Ω) after an uneventful early postoperative period. Seven (70%) of the malfunctioning leads were SonRtip leads (p <0.001). Lead replacement was needed in 4.2% of SonRtip leads (six out of 143) and in 0.38% of all other conventional atrial leads (two out of 526) (p <0.001). Because of unaltered atrial sensing properties, a wait and see strategy was chosen in two patients-one of them with a SonRtip lead. The implanted atrial lead in the latter person experienced a sudden increase in pacing threshold (4V/0.35ms). CONCLUSIONS: While short-term safety and stable technical performance of the SonRtip atrial lead could be confirmed, our study found an unexpectedly high malfunction rate over a longer follow-up period.


Subject(s)
Atrial Fibrillation/therapy , Cardiac Resynchronization Therapy Devices , Cardiac Resynchronization Therapy , Myocardial Contraction , Aged , Aged, 80 and over , Atrial Fibrillation/physiopathology , Equipment Failure , Female , Humans , Male , Middle Aged
15.
Article in English | MEDLINE | ID: mdl-30480387

ABSTRACT

Transcatheter treatment of structural heart disease is becoming an everyday reality for an increasing number of surgeons, and effective training modalities for basic guide-wire skills, catheter handling, and periprocedural imaging are of growing relevance. In this video tutorial we present a beating-heart porcine model used as a high-fidelity training simulator for transcatheter cardiac valve procedures.  We demonstrate a complete transcatheter edge-to-edge mitral valve repair procedure, including periprocedural imaging, clip deployment, and quality control. Various mitral valve pathologies can be simulated, including the demonstrated leaflet prolapse. Trainees practice clip navigation within the left atrium, transmitral passage, and clip orientation as well as grasping mitral valve leaflets to treat mitral regurgitation.  Periprocedural imaging is achieved via epicardial echocardiography and left ventricular cardioscopy, and these imaging modalities are also relied on to guide surgeons during the simulations, as required. The beating heart model enables realistic demonstration of the hemodynamic consequences of valve repair, and we believe that this simulator represents a valuable adjunct to surgical training.


Subject(s)
Cardiac Catheterization/methods , Cardiac Surgical Procedures/methods , Computer Simulation , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Thoracic Surgery/education , Animals , Disease Models, Animal , Echocardiography , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/diagnosis , Swine
16.
PLoS One ; 13(4): e0195573, 2018.
Article in English | MEDLINE | ID: mdl-29624601

ABSTRACT

BACKGROUND: Sleep disordered breathing is a common but often undiagnosed comorbidity in heart failure patients. Cardiac implantable electronic devices used for cardiac resynchronization therapy (CRT) may detect sleep apnea by use of a transthoracic impedance sensor. Validation of the AP scan® algorithm (Boston Scientific®) was performed by using the diagnostic gold standard polysomnography (PSG). METHODS: Forty-one patients with impaired left ventricular ejection fraction, frequent right ventricular pacing due to atrioventricular block and heart failure symptoms despite optimal medical therapy underwent upgrading to biventricular pacing. Within one month after left ventricular lead implantation, sleep apnea was assessed by single-night PSG and AP scan® measurements. RESULTS: AP scan® measurements were valid in only 21 of 41 (51.2%) patients in the index night of the PSG. The PSG determined apnea-hypopnea index did not correlate statistically significant with the AP scan® measurements (r = 0.41, 95% confidence interval -0.05-0.72, p = 0.07). The degree of overestimation is displayed by using the Bland-Altman method: mean difference -12.4, standard deviation ± 15.8, 95% confidence interval -43.3-18.6. CONCLUSIONS: In heart failure patients receiving CRT upgrading, the AP scan® algorithm may need further improvement before it can be recommended for sleep apnea detection.


Subject(s)
Cardiac Resynchronization Therapy Devices , Heart Failure/complications , Polysomnography , Sleep Apnea Syndromes/complications , Sleep Apnea Syndromes/diagnosis , Aged , Algorithms , Cardiac Resynchronization Therapy , Cardiac Resynchronization Therapy Devices/statistics & numerical data , Cardiography, Impedance , Cross-Over Studies , Double-Blind Method , Female , Heart Failure/therapy , Humans , Male , Polysomnography/statistics & numerical data , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/therapy
17.
Int J Cardiol ; 260: 11-15, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29530620

ABSTRACT

OBJECTIVE: Vitamin K antagonists (VKA) are associated with increased vascular calcification which may lead to an elevated cardiovascular risk. If the direct anticoagulants (DOACs) have similar negative vascular effects is unknown. We evaluated the influence of different anticoagulation strategies on coronary artery disease (CAD) using coronary computed tomography angiography (CTA). METHODS: Overall 702 consecutive patients with non-valvular atrial fibrillation (AF) who underwent CTA for AF ablation planning were enrolled and stratified according to their anticoagulation into VKA, DOAC (all agents) and a control group without oral anticoagulation. Patients were propensity score matched 1:1:1, significant structural heart disease and comorbidities were excluded. CT images were evaluated for plaque burden (calcium score, segment involvement score (SIS) and non-calcified SIS, stenosis grading) and plaque morphology (high risk plaque features: low attenuation, positive remodeling, napkin-ring sign, spotty calcification). RESULTS: Final analysis included 303 patients (101 patients each group) and showed increased overall plaque burden in patients using VKA compared to DOAC users and the control group (mean affected segments 2.58 vs 1.58 vs 2.100, p = 0.008), and a higher prevalence of high-risk plaque (HRP) features (42.6% vs 13.9% vs 26.7%, p < 0.0001). Patients treated with DOACs did not differ in conventional CT findings from the control group and showed an even lower prevalence of selected HRP features compared to the control group: low-attenuation plaques (4.0% vs. 14.4%, p = 0.014) and napkin-ring sign (0 vs. 5.0%, p = 0.029). CONCLUSION: Vitamin K antagonists are associated with a higher plaque burden and increased high-risk plaque features, whereas DOACs may yield a benefit in cardiovascular atherosclerosis.


Subject(s)
Anticoagulants/administration & dosage , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/drug therapy , Vitamin K/antagonists & inhibitors , Administration, Oral , Adult , Aged , Female , Humans , Male , Middle Aged , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/drug therapy , Retrospective Studies
18.
ESC Heart Fail ; 5(1): 201-203, 2018 02.
Article in English | MEDLINE | ID: mdl-29345417

ABSTRACT

We report a case of catheter-based edge-to-edge mitral valve repair in a teenage male patient with non-ischaemic cardiomyopathy to improve pulmonary hypertension secondary to severe functional mitral regurgitation (FMR) to defer anticipated heart transplantation. A 19-year-old patient with previous history of fulminant myocarditis followed by markedly left ventricular dysfunction presented with severe mitral regurgitation 3 years after initial recovery. Slightly over time, deterioration of FMR was associated with gradual increase in pulmonary artery pressures despite optimal medical therapy. MitraClip implantation in this young patient was successfully performed with sustainable improvement of pulmonary hypertension.


Subject(s)
Cardiac Catheterization/methods , Hypertension, Pulmonary/etiology , Mitral Valve Annuloplasty/methods , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Pulmonary Wedge Pressure/physiology , Adolescent , Echocardiography, Transesophageal , Heart Transplantation , Humans , Hypertension, Pulmonary/physiopathology , Male , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnosis
19.
Br Med Bull ; 120(1): 101-109, 2016 12.
Article in English | MEDLINE | ID: mdl-27784660

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) affects 1-2% of the population, and its prevalence is estimated to at least double in the next 50 years as the population ages. AREAS OF AGREEMENT: AF results in impaired quality of life and even increased mortality. Drugs frequently fail to stabilize sinus rhythm. AREAS OF CONTROVERSY: Catheter ablation is a valuable treatment alternative, even as a first-line therapy in selected cases. However, catheter ablation of AF is challenging, even for experienced operators. GROWING POINTS: Simplification of catheter ablation of AF is essential to decrease the threshold for treatment, broaden the access to the therapy and contribute to further reduction of the disease burden. Single-shot devices, that are easy to navigate in the heart, are an essential element in efforts to reach this goal. AREAS TIMELY FOR DEVELOPING RESEARCH: Cryoenergy is an excellent energy source to combine with a single-shot device, resulting in an excellent safety profile and good clinical results while maintaining its ease of use.


Subject(s)
Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/surgery , Catheter Ablation , Cryosurgery , Postoperative Complications/etiology , Atrial Fibrillation/physiopathology , Catheter Ablation/methods , Cryosurgery/methods , Humans , Quality of Life , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...