Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
HardwareX ; 17: e00506, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38497030

ABSTRACT

Photocatalytic water treatment is considered a promising technique to prevent micropollutants from entering the environment. However, no off-the-shelf UV reactors on lab scale are available to study new processes and photocatalysts. In this study, we present a tubular UV reactor equipped with 30 UV-LEDs, emitting UV light at 367 nm and a total radiant flux of 42 W. The UV reactor has an irradiated length of 300 mm and can host any transparent chemical reactor on the inside with a maximum diameter of 28 mm. The device is optimized for lab experiments with total dimensions of just 334 mm x 193 mm x 172 mm. Besides water treatment, a broad range of other photochemical and photocatalytic experiments can be performed with the reactor. Two identical UV reactors have been built and are successfully used for photocatalytic water treatment experiments. The degradation of methylene blue with TiO2 as photocatalyst was studied to validate the UV reactor. Furthermore, photocatalytic and hybrid processes were conducted in the UV reactor to degrade a broad range of pharmaceutical micropollutants.

2.
Sci Rep ; 11(1): 24490, 2021 12 29.
Article in English | MEDLINE | ID: mdl-34966168

ABSTRACT

During the first wave of Covid-19 infections in Germany in April 2020, clinics reported a shortage of filtering face masks with aerosol retention> 94% (FFP2 & 3, KN95, N95). Companies all over the world increased their production capacities, but quality control of once-certified materials and masks came up short. To help identify falsely labeled masks and ensure safe protection equipment, we tested 101 different batches of masks in 993 measurements with a self-made setup based on DIN standards. An aerosol generator provided a NaCl test aerosol which was applied to the mask. A laser aerosol spectrometer measured the aerosol concentration in a range from 90 to 500 nm to quantify the masks' retention. Of 101 tested mask batches, only 31 batches kept what their label promised. Especially in the initial phase of the pandemic in Germany, we observed fluctuating mask qualities. Many batches show very high variability in aerosol retention. In addition, by measuring with a laser aerosol spectrometer, we were able to show that not all masks filter small and large particles equally well. In this study we demonstrate how important internal and independent quality controls are, especially in times of need and shortage of personal protection equipment.


Subject(s)
COVID-19/prevention & control , COVID-19/transmission , Masks/statistics & numerical data , Aerosols , Filtration/instrumentation , Germany , Humans , Masks/standards , Masks/trends , N95 Respirators/standards , N95 Respirators/statistics & numerical data , Occupational Exposure/prevention & control , Pandemics/prevention & control , Personal Protective Equipment/standards , Quality Control , Respiratory Protective Devices/standards , SARS-CoV-2/pathogenicity
3.
Sci Rep ; 9(1): 18998, 2019 Dec 12.
Article in English | MEDLINE | ID: mdl-31831846

ABSTRACT

Colloidal filtration processes using porous membranes suffer from productivity loss due to colloidal matter retention and continuous build-up by the retained matter. Especially during filtration of soft matter, the deformation of the individual colloids that make up the filter cake may be significant; however, this deformation and its impact remain unresolved so far. Yet, understanding the deformation on the single colloid level as well as on the ensemble level is important to be able to deconvolute filter cake properties from resistance increase of the membrane either by simultaneous internal adsorption or blocking of pores. Here, we report on the compression of a filter cake by filtrating soft microgels in a microfluidic channel in front of a model membrane. To study the single colloid deformation amorphous and crystalline domains were built up in front of the membrane and visualized on-line using confocal fluorescence microscopy while adjusting the degree of permeation, i.e., the transmembrane flux. Results show locally pronounced asymmetric deformation in amorphous domains, while the microgels in colloidal crystals approached regular polyeder shape. Increasing the flux beyond the maximum colloid deformation results in non-isochoric microgel behavior. The presented methodology enables a realistic description of complex colloidal matter deposits during filtration.

SELECTION OF CITATIONS
SEARCH DETAIL
...