Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Acta Orthop Scand ; 72(2): 133-40, 2001 Apr.
Article in English | MEDLINE | ID: mdl-11372943

ABSTRACT

We compared the efficacy of the Medoff sliding plate (MSP) with 3 other screw-plate systems for fixation of unstable intertrochanteric fractures in a randomized multicenter trial of 569 elderly patients. The MSP has biaxial dynamic capacity along both the neck and the shaft of the femur unlike the other systems, which lack dynamic capacity along the shaft. 268 fractures were operated on with the MSP, and 301 with the dynamic hip screw (DHS), with or without a trochanteric stabilizing plate (DHS/TSP) or with the dynamic condylar screw (DCS). The MSP had recently been shown to the surgeons. The patients in the groups were similar as regards age, domestic situation, preinjury walking ability and type of fracture. We followed the patients clinically and radiographically for at least 1 year. There was no significant difference in walking ability at follow-up or rate of return to home. Fixation failure occurred in 18/268 fractures operated on with the MSP, in 8/238 with the DHS, in 3/49 with the DHS/TSP and in 1/14 with the DCS. The difference in the rate of fixation failure was not statistically significant when the MSP group was compared to the 3 other groups. In 14 of the 18 fixation failures in the MSP group, the biaxial dynamic capacity of the MSP had not been used due to technical errors by surgeons, unfamiliar with the new method. No selection bias was found regarding fracture types in the 2 subgroups of patients with correct or inadequate biaxial dynamization. Extramedullary fixation of unstable intertrochanteric fractures with these implants showed a low failure rate. When using the MSP, biaxial dynamization must be correctly performed.


Subject(s)
Bone Plates , Bone Screws , Fracture Fixation, Internal/instrumentation , Hip Fractures/surgery , Adult , Aged , Aged, 80 and over , Equipment Design , Female , Hip Fractures/diagnostic imaging , Humans , Male , Middle Aged , Prospective Studies , Radiography , Treatment Outcome , Walking
2.
Acta Orthop Scand ; 70(5): 459-66, 1999 Oct.
Article in English | MEDLINE | ID: mdl-10622478

ABSTRACT

We compared the efficacy of a load-sharing device, the Medoff sliding plate (MSP), with that of 3 other load-bearing screw-plate devices for the fixation of subtrochanteric fractures in a randomized multicenter trial of 107 elderly patients. 55 fractures were operated on with the MSP, and 52 with the dynamic hip screw (DHS) with or without a trochanteric stabilizing plate (TSP) or with the dynamic condylar screw (DCS). The patient material in the groups was similar regarding age, domestic situation, preinjury walking ability and fracture types. We followed the patients clinically and radiographically for a minimum of 1 year. There was no significant difference in walking ability or return rate to the home at follow-up. Fixation failure occurred in 1/55 fractures operated on with the MSP, in 3/32 with the DHS, in 3/12 with the DCS and in 2/8 with the DHS/TSR The difference in the rate of fixation failure was statistically significant, when the MSP group was compared to the 3 load-bearing devices in the other group (1 vs 8). On the basis of this experience, we think that the load-sharing principle of the MSP, which seems to facilitate fracture impaction and stability, appears to be a good alternative in extramedullary fixation of subtrochanteric fractures.


Subject(s)
Bone Plates/standards , Bone Screws/standards , Fracture Fixation, Internal/instrumentation , Hip Fractures/surgery , Prosthesis Failure , Aged , Aged, 80 and over , Equipment Failure Analysis , Female , Hip Fractures/classification , Hip Fractures/diagnostic imaging , Hip Fractures/physiopathology , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Radiography , Treatment Outcome , Walking , Weight-Bearing
SELECTION OF CITATIONS
SEARCH DETAIL
...