Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 78
Filter
1.
Article in English | MEDLINE | ID: mdl-38841916

ABSTRACT

BACKGROUND: Residual transprosthetic gradient (TG) after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEV) may be due to suboptimal valve expansion. AIMS: To compare hemodynamics after TAVR with small BEV according to postdilation strategy. METHODS: This observational, retrospective cohort study included 184 consecutive patients from a single center treated with 23 mm Sapien 3 Ultra (Edwards Lifesciences) BEV implantation in the aortic position and enrolled between January 2020 and April 2023. Patients treated with routine postdilation (RP, n = 73) were compared to patients treated according to local standard practice (SP, n = 111). Primary endpoint was 30-day mean TG. Secondary endpoints were incidence of 30-day prosthesis-patient mismatch (PPM), technical success and device success. RESULTS: Thirty-day mean TG was lower in RP versus SP (12.3 ± 4.6 mmHg vs. 14.1 ± 5.7 mmHg, p = 0.031), and incidence of PPM was less common with RP versus SP (47.3% vs. 71.0%, p = 0.006). Technical success (98.6% vs. 99.1%, p = 0.637) and device success (93.1% vs. 90.1%, p = 0.330) did not differ between groups. Differences in 30-day mean TG were driven by patients at normal flow (12.1 ± 4.0 mmHg vs. 15.0 ± 5.5 mmHg, p = 0.014), while no differences were evident among patients at low flow (12.5 ± 5.5 mmHg vs. 11.7 ± 5.5 mmHg, p = 0.644). RP decreased height and increased width of BEV, and a linear regression established that final BEV width could predict 30-day mean TG (r = -0.6654, p < 0.0001). CONCLUSIONS: RP after TAVR with small BEV was associated with more favorable forward-flow hemodynamics than SP.

2.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38749619

ABSTRACT

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Severity of Illness Index
3.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599688

ABSTRACT

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Cardiac Catheterization/methods , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Multicenter Studies as Topic , Registries
4.
Circulation ; 149(22): e1223-e1238, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38660790

ABSTRACT

Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.


Subject(s)
American Heart Association , Tricuspid Valve , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/pathology , United States , Heart Valve Diseases/therapy , Heart Valve Diseases/diagnostic imaging , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/therapy , Heart Valve Prosthesis Implantation
6.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Article in English | MEDLINE | ID: mdl-38099912

ABSTRACT

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Predictive Value of Tests , Recovery of Function , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Male , Female , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Treatment Outcome , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Aged , Risk Factors , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Feasibility Studies , Risk Assessment , Prosthesis Design , Echocardiography, Three-Dimensional
7.
Front Cardiovasc Med ; 10: 1180299, 2023.
Article in English | MEDLINE | ID: mdl-38045907

ABSTRACT

New generation 3-dimensional matrix array intracardiac echocardiography catheters have become commercially available recently, increasing image plane options compared to 2-dimensional and older generation 3-dimensional intracardiac echocardiography catheters. They are beginning to play an important role in structural heart interventions, especially for transcatheter tricuspid interventions, due to advantages in some situations that increase image quality over transesophageal echocardiography.

8.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-37930776

ABSTRACT

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Quality of Life , Treatment Outcome , Cardiac Catheterization/methods , Severity of Illness Index
9.
Eur J Heart Fail ; 25(12): 2243-2251, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37905381

ABSTRACT

AIM: Functional or secondary tricuspid regurgitation (STR) is the most common phenotype of tricuspid regurgitation (TR) with atrial STR (ASTR) and ventricular STR (VSTR) being recently identified as two distinct entities. Data on tricuspid transcatheter edge-to-edge repair (T-TEER) in patients with STR according to phenotype (i.e. ASTR vs. VSTR) are lacking. The aim of this study was to assess characteristics and outcomes of patients with ASTR versus VSTR undergoing T-TEER. METHODS AND RESULTS: Patients with STR undergoing T-TEER were selected from the Transcatheter Tricuspid Valve Therapies (TriValve) registry. ASTR was defined by (i) left ventricular ejection fraction ≥50%, (ii) atrial fibrillation, and (iii) systolic pulmonary artery pressure <50 mmHg. Patients not matching these criteria were classified as VSTR. Patients with primary TR and cardiac implantable electronic device were excluded. Key endpoints included procedural success and survival at follow-up. A total of 298 patients were enrolled in the study: 65 (22%) with ASTR and 233 (78%) with VSTR. Procedural success was similar in the two groups (80% vs. 83% for ASTR vs. VSTR, p = 0.56) and TEER was effective in reducing TR in both groups (from 97% of patients with baseline TR ≥3+ to 23% in ASTR and to 15% in VSTR, all p = 0.001). At 12-month follow-up, survival was significantly higher in the ASTR versus VSTR cohort (91% vs. 72%, log-rank p = 0.02), with VSTR being an independent predictor of mortality at multivariable analysis (hazard ratio 4.75). CONCLUSIONS: In a real-world, multicentre registry, T-TEER was effective in reducing TR grade in both ASTR and VSTR. At 12-month follow-up, ASTR showed better survival than VSTR.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/complications , Tricuspid Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/methods , Stroke Volume , Treatment Outcome , Cardiac Catheterization/methods , Heart Failure/etiology , Ventricular Function, Left , Registries
10.
Heart Fail Clin ; 19(4): 491-504, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37714589

ABSTRACT

Current guidelines of aortic stenosis (AS) management focus on valve parameters, LV systolic dysfunction, and symptoms; however, emerging data suggest that there may be benefit of aortic valve replacement before it becomes severe by present criteria. Myocardial assessment using novel multimodality imaging techniques exhibits subclinical myocardial injury and remodeling at various stages before guideline-directed interventions, which predicts adverse outcomes. This raises the question of whether implementing serial myocardial assessment should become part of the standard appraisal, thereby identifying high-risk patients aiming to minimize adverse outcomes.


Subject(s)
Aortic Valve Stenosis , Multimodal Imaging , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Myocardium
11.
Int J Cardiol ; 390: 131139, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37355239

ABSTRACT

BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.


Subject(s)
Heart Failure , Heart Transplantation , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Middle Aged , Stroke Volume , Ventricular Function, Left , Time Factors , Heart Transplantation/adverse effects , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Heart Failure/diagnosis , Heart Failure/surgery , Registries , Heart Valve Prosthesis Implantation/methods
12.
JACC Case Rep ; 12: 101776, 2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37091051

ABSTRACT

Patients with tricuspid regurgitation are often referred late in their disease course and present with volume overload, which is a detrimental factor leading to right-sided chamber dilatation and dysfunction. Treatment of volume overload can 1) improve patient functional status; 2) avoid repeated invasive examinations; and 3) establish eligibility for transcatheter tricuspid intervention. (Level of Difficulty: Intermediate.).

13.
Article in English | MEDLINE | ID: mdl-36948892

ABSTRACT

BACKGROUND: Data regarding the impact of the tricuspid valve gradient (TVG) after tricuspid transcatheter edge-to-edge repair (TEER) are scarce. OBJECTIVES: This study sought to evaluate the association between the mean TVG and clinical outcomes among patients who underwent tricuspid TEER for significant tricuspid regurgitation. METHODS: Patients with significant tricuspid regurgitation who underwent tricuspid TEER within the TriValve (International Multisite Transcatheter Tricuspid Valve Therapies) registry were divided into quartiles based on the mean TVG at discharge. The primary endpoint was the composite of all-cause mortality and heart failure hospitalization. Outcomes were assessed up to the 1-year follow-up. RESULTS: A total of 308 patients were included from 24 centers. Patients were divided into quartiles of the mean TVG as follows: quartile 1 (n = 77), 0.9 ± 0.3 mm Hg; quartile 2 (n = 115), 1.8 ± 0.3 mm Hg; quartile 3 (n = 65), 2.8 ± 0.3 mm Hg; and quartile 4 (n = 51), 4.7 ± 2.0 mm Hg. The baseline TVG and the number of implanted clips were associated with a higher post-TEER TVG. There was no significant difference across TVG quartiles in the 1-year composite endpoint (quartiles 1-4: 35%, 30%, 40%, and 34%, respectively; P = 0.60) or the proportion of patients in New York Heart Association class III to IV at the last follow-up (P = 0.63). The results were similar after adjustment for clinical and echocardiographic characteristics (composite endpoint quartile 4 vs quartile 1-quartile 3 adjusted HR: 1.05; 95% CI: 0.52-2.12; P = 0.88) or exploring post-TEER TVG as a continuous variable. CONCLUSIONS: In this retrospective analysis of the TriValve registry, an increased discharge TVG was not significantly associated with adverse outcomes after tricuspid TEER. These findings apply for the explored TVG range and up to the 1-year follow-up. Further investigations on higher gradients and longer follow-up are needed to better guide the intraprocedural decision-making process.

14.
Can J Cardiol ; 39(5): 581-589, 2023 05.
Article in English | MEDLINE | ID: mdl-36690327

ABSTRACT

BACKGROUND: Transcatheter therapies are a recognized alternative intervention in patients with severe mitral regurgitation who are at high surgical risk. The purpose of this study was to characterize patients screened for transcatheter mitral valve replacement (TMVR), establish the clinical and anatomic reasons for unsuitability, and determine clinical course and early outcomes. METHODS: International multicentre registry was conducted of consecutive patients screened for TMVR at 12 centres in Europe, the United States, and Canada between April 2015 and September 2018. Patient-level retrospective data were collected for all patients screened. RESULTS: From a total of 294 patients, 87 (30%) patients were suitable for and underwent TMVR, whereas 207 (70%) patients were unsuitable for TMVR. There was no difference in Society of Thoracic Surgeons predicted risk of mortality (6.3% ± 4.3% vs 6.7 ± 6.1%, P = 0.52) for mitral valve replacement between the groups. The most common reasons for TMVR unsuitability were mitral annular size outside therapeutic range (28%) and small predicted neo-LVOT (25%). Preprocedural multidetector computed tomographic demonstrated that patients unsuitable for TMVR had smaller predicted neo-left ventricular outflow tract (LVOT) area (318 ±192 mm2 vs 495 ± 202 mm2, P = 0.04). At 30 days, there was no difference in rates of rehospitalization (8% vs 8%, P = 0.21), stroke (1% vs 2%, P = 0.42), or mortality (4% vs 10%, P = 0.10), unadjusted for procedural risk, between unsuitable for TMVR and TMVR groups, respectively. CONCLUSIONS: Two-thirds of patients failed screening as anatomically unsuitable for TMVR. The findings of this study have important clinical implications, highlighting an unmet clinical need and provide a target for design innovation in future iterations of TMVR devices.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Ventricular Outflow Obstruction , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Risk Factors , Cardiac Catheterization/methods , Treatment Outcome , Ventricular Outflow Obstruction/surgery , Registries , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/surgery
15.
J Clin Med ; 12(1)2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36615141

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has risen over the past 20 years as a safe and effective alternative to surgical aortic valve replacement for treatment of severe aortic stenosis, and is now a well-established and recommended treatment option in suitable patients irrespective of predicted risk of mortality after surgery. Studies of numerous devices, either newly developed or reiterations of previous prostheses, have been accruing. We hereby review TAVI devices, with a focus on commercially available options, and aim to present a guide for prosthesis tailoring according to patient-related anatomical and clinical factors that may favor particular designs.

16.
Eur Heart J ; 44(10): 822-832, 2023 03 07.
Article in English | MEDLINE | ID: mdl-36445158

ABSTRACT

AIMS: The impact of sexuality in patients with significant tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI) is unknown. The aim of this study was to investigate sex-specific outcomes in patients with significant TR treated with TTVI vs. medical therapy alone. METHODS AND RESULTS: The Transcatheter Tricuspid Valve Therapies (TriValve) registry collected data on patients with significant TR from 24 centres who underwent TTVI from 2016 to 2021. A control cohort was formed by medically managed patients with ≥severe isolated TR diagnosed in 2015-18. The primary endpoint was freedom from all-cause mortality. Secondary endpoints were heart failure (HF) hospitalization, New York Heart Association (NYHA) functional status, and TR severity. One-year outcomes were assessed for the TriValve cohort and compared with the control cohort with the inverse probability of treatment weighting (IPTW). A total of 556 and 2072 patients were included from the TriValve and control groups, respectively. After TTVI, there was no difference between women and men in 1-year freedom from all-cause mortality 80.9% vs. 77.9%, P = 0.56, nor in HF hospitalization (P = 0.36), NYHA Functional Classes III and IV (P = 0.17), and TR severity >2+ at last follow-up (P = 0.42). Multivariable Cox-regression weighted by IPTW showed improved 1-year survival after TTVI compared with medical therapy alone in both women (adjusted hazard ratio 0.45, 95% confidence interval 0.23-0.83, P = 0.01) and men (adjusted hazard ratio 0.42, 95% confidence interval 0.18-0.89, P = 0.03). CONCLUSION: After TTVI in high-risk patients, there were no sex-related differences in terms of survival, HF hospitalization, functional status, and TR reduction up to 1 year. The IPTW analysis shows a survival benefit of TTVI over medical therapy alone in both women and men.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Male , Humans , Female , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Registries , Heart Failure/complications
17.
EuroIntervention ; 18(10): 840-851, 2022 Nov 18.
Article in English | MEDLINE | ID: mdl-36197445

ABSTRACT

BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) is rapidly emerging as a therapeutic option amongst patients with secondary tricuspid regurgitation. Historical data from surgical tricuspid valve replacement (TVR) studies may serve as a benchmark for the development of TTVR trials. AIMS: The aim of the study was to investigate the early and late outcomes following isolated surgical TVR. METHODS: Multiple electronic databases were searched to identify studies on isolated surgical TVR. The prespecified primary endpoint was operative mortality; secondary endpoints were early and late outcomes. Overall estimates of proportions and incidence rates with 95% confidence intervals (CI) were calculated using random-effects models. Multiple sensitivity analyses accounting for baseline characteristics, country and the operative period were applied.  Results: A total of 35 studies (5,316 patients) were included in this meta-analysis. The operative period ranged from 1974 to 2019. The overall rate of operative mortality was 12% (95% CI: 9-15), with higher mortality for patients who were operated on before 1995, who had prior cardiac surgeries, or who had liver disease. The most frequent clinical events were pacemaker implantation (10% [95% CI: 6-16]), bleeding (12% [95% CI: 8-17]), acute kidney injury (15% [95% CI: 9-24]) and respiratory complications (15% [95% CI: 12-20]). At follow-up analysis of the bioprosthetic TVR, there was an incidence rate per 100 person-years of 6 (95% CI: 2-13) for death and 8 (95% CI: 5-13) for recurrence of significant tricuspid regurgitation. CONCLUSIONS: This meta-analysis provides an overview of the historical clinical outcomes following isolated surgical TVR. These findings can support the development of future clinical trials in the tricuspid space by providing thresholds for clinical outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/complications , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome , Retrospective Studies
19.
JACC Cardiovasc Interv ; 15(16): 1664-1674, 2022 08 22.
Article in English | MEDLINE | ID: mdl-35981841

ABSTRACT

BACKGROUND: The clinical course of patients with moderate aortic stenosis (AS) remains incompletely defined. OBJECTIVES: This study sought to analyze the clinical course of moderate AS and compare it with other stages of the disease. METHODS: Multiple electronic databases were searched to identify studies on adult moderate AS. Random-effects models were used to derive pooled estimates. The primary endpoint was all-cause death. The secondary endpoints were cardiac death, heart failure, sudden death, and aortic valve replacement. RESULTS: Among a total of 25 studies (12,143 moderate AS patients, 3.7 years of follow-up), pooled rates per 100 person-years were 9.0 (95% CI: 6.9 to 11.7) for all-cause death, 4.9 (95% CI: 3.1 to 7.5) for cardiac death, 3.9 (95% CI: 1.9 to 8.2) for heart failure, 1.1 (95% CI: 0.8 to 1.5) for sudden death, and 7.2 (95% CI: 4.3 to 12.2) for aortic valve replacement. Meta-regression analyses detected that diabetes (P = 0.019), coronary artery disease (P = 0.017), presence of symptoms (P < 0.001), and left ventricle (LV) dysfunction (P = 0.009) were associated with a significant impact on the overall estimate of all-cause death. All-cause mortality was higher in patients with reduced LV ejection fraction (<50%) than with normal LV ejection fraction: 16.5 (95% CI: 5.2 to 52.3) and 4.2 (95% CI: 1.4 to 12.8) per 100 person-years, respectively. Compared with moderate AS, the incidence rate difference of all-cause mortality was -3.9 (95% CI: -6.7 to -1.1) for no or mild AS and +2.2 (95% CI: +0.8 to +3.5) for severe AS patients. CONCLUSIONS: Moderate AS appears to be associated with a mortality risk higher than no or mild AS but lower than severe AS, which increases in specific population subsets. The impact of early intervention in moderate AS patients having high-risk features deserves further investigation.


Subject(s)
Aortic Valve Stenosis , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Death , Death, Sudden , Heart Failure , Humans , Transcatheter Aortic Valve Replacement , Treatment Outcome
20.
JACC Case Rep ; 4(7): 385-390, 2022 Apr 06.
Article in English | MEDLINE | ID: mdl-35693900

ABSTRACT

Biological mitral valve restenosis after replacement in rheumatic heart disease is a rare complication. This case illustrates venoarterial extracorporeal membrane oxygenation to facilitate transcatheter mitral valve replacement in a patient with suprasystemic pulmonary pressure and cardiogenic shock with multiorgan failure secondary to critical mitral stenosis of a bioprosthetic valve.(Level of Difficulty: Advanced.).

SELECTION OF CITATIONS
SEARCH DETAIL
...