Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
HIV Med ; 21(10): 650-658, 2020 11.
Article in English | MEDLINE | ID: mdl-32876389

ABSTRACT

OBJECTIVES: The characteristics of critically ill HIV-positive patients and the causes of their admission to intensive care units (ICUs) are only known through retrospective and unicentric studies. This study aims to fill this knowledge gap. METHODS: This is a prospective, multicentre cohort study of short- and medium-term prognostic factors. The setting consisted of ICUs of three tertiary referral hospitals from the three largest metropolitan areas in Brazil in the period January 2014 to November 2015. In all, 161 HIV patients over 18 years old were included. RESULTS: The clinical data of the outcomes (ICU mortality, hospital mortality and 90-day survival) were extracted from medical records using the REDCap®ï¸ web-based form and analysed with the MedCalc®ï¸ application. Median age was 41.7 [interquartile range (IQR): 34-50] years, the Simplified Acute Physiologic Score 3 (SAPS 3) was 64 (IQR: 56-74), and the Sequential Organ Failure Assessment Score (SOFA) was 6 (IQR: 4-9) points. The main causes of admission were sepsis (54.5%) and acute respiratory failure (13.7%). ICU and hospital mortality rates were 32.3% and 40.4%, respectively. In a multivariate analysis, time until ICU admission ≥ 3 days (P = 0.0013), performance status (Eastern Cooperative Oncology Group score, P = 0.0344), coma (Glasgow Coma Scale ≤ 8 points, P = 0.0213) and sepsis (P = 0.0003) were associated with increased hospital mortality. Coma (P = 0.0002) and sepsis (P = 0.0008) were independently associated with 90-day survival. CONCLUSIONS: Delayed ICU admission and the severity of critical illness determine the short- and medium-term mortality rates of HIV-infected patients admitted to the ICU, rather than factors associated with HIV infection. These results suggest that prognostic factors of HIV-infected patients in the ICU are similar to those of non-HIV-infected populations.


Subject(s)
Critical Illness/mortality , HIV Infections/mortality , Respiratory Insufficiency/epidemiology , Sepsis/epidemiology , Adult , Aged , Brazil/epidemiology , Critical Care , Female , Hospital Mortality , Humans , Male , Middle Aged , Patient Admission/statistics & numerical data , Prognosis , Prospective Studies , Respiratory Insufficiency/mortality , Sepsis/mortality
2.
Med J Malaysia ; 75(5): 555-560, 2020 09.
Article in English | MEDLINE | ID: mdl-32918426

ABSTRACT

INTRODUCTION: Hyperhidrosis is a disorder of excessive and uncontrollable sweating beyond the body's physiological needs. It can be categorised into primary or secondary hyperhidrosis based on its aetiology. Detailed history review including onset of symptoms, laterality of disease and family history are crucial which may suggest primary hyperhidrosis. Secondary causes such as neurological diseases, endocrine disorders, haematological malignancies, neuroendocrine tumours and drugs should be adequately examined and investigated prior to deciding on further management. The diagnosis of primary hyperhidrosis should only be made only after excluding secondary causes. Hyperhidrosis is a troublesome disorder that often results in social, professional, and psychological distress in sufferers. It remains, however, a treatment dilemma among some healthcare providers in this region. METHODS: The medical records and clinical outcomes of 35 patients who underwent endoscopic thoracic sympathectomy for primary hyperhidrosis from 2008 to 2018 in Department of Cardiothoracic Surgery were reviewed. RESULTS: The mean age of the patients was 27±10.1years, with male and female distribution of 18 and 17, respectively. Fifty-one percent of patients complained of palmar hyperhidrosis, while 35% of them had concurrent palmaraxillary and 14% had palmar-plantar-axillary hyperhidrosis. Our data showed that 77% (n=27) of patients were not investigated for secondary causes of hyperhidrosis, and they were not counselled on the non-surgical therapies. All patients underwent single-staged bilateral endoscopic thoracic sympathectomy. There was resolution of symptoms in all 35 (100%) patients with palmar hyperhidrosis, 13(76%) patients with axillary hyperhidrosis and only 2 (50%) patients with plantar hyperhidrosis. Postoperatively 34.3% (n=12) of patients reported compensatory hyperhidrosis. There were no other complications such as pneumothorax, chylothorax, haemothorax and Horner's Syndrome. CONCLUSION: Clinical evaluation of hyperhidrosis in local context has not been well described, which may inadvertently result in the delay of appropriate management, causing significant social and emotional embarrassment and impair the quality of life of the subjects. Detailed clinical assessment and appropriate timely treatment, be it surgical or non-surgical therapies, are crucial in managing this uncommon yet distressing disease.


Subject(s)
Endoscopy , Hyperhidrosis/diagnosis , Hyperhidrosis/surgery , Patient Satisfaction , Sympathectomy/methods , Thoracoscopy/methods , Adolescent , Adult , Female , Humans , Male , Medical Audit , Medical Records , Outcome Assessment, Health Care , Young Adult
3.
Opt Express ; 26(25): 33245-33252, 2018 Dec 10.
Article in English | MEDLINE | ID: mdl-30645480

ABSTRACT

For an efficient single-photon source a high-count rate into a well-defined spectral and spatial mode is desirable. Here we have developed a hybrid planar Fabry-Pérot microcavity by using a two-photon polymerization process (2PP) where coupling between single-photon sources (diamond colour centres) and resonance modes is observed. The first step consists of using the 2PP process to build a polymer table structure around previously characterized nitrogen-vacancy (NV) centres on top of a distributed Bragg reflector (DBR) with a high reflectivity at the NV zero-phonon line (ZPL). Afterwards, the polymer structure is covered with a silver layer to create a weak (low Q) cavity where resonance fluorescence measurements from the NVs are shown to be in good agreement with analytical and Finite Difference Time Domain (FDTD) results.

4.
J Virol Methods ; 186(1-2): 184-8, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22989408

ABSTRACT

Data on analytical sensitivity of rapid diagnostic assays are important for clinical management of influenza, especially during a pandemic. Four rapid antigen detection assays were compared for detection of pandemic influenza A H1N1 2009, seasonal H1N1 and H3N2 in 96 patients with influenza A infection confirmed by real-time RT-PCR. These rapid antigen tests appeared to have lower sensitivity (55.8%) for the diagnosis of pandemic influenza A H1N1 2009 as compared with seasonal H3N2 (71.0%) or H1N1 (69.4%) influenza infections, a difference that was related to a lower viral load in patients infected with the pandemic influenza A H1N1 2009 virus. The detection limit of these antigen detection tests in clinical specimens was an influenza A M gene copy number of average 1.0×10(7) copies/ml. Significant variations between tests in sensitivity for detection of pandemic influenza A H1N1 2009 (43.4-63.3%) were observed. The Directigen EZ Influenza A+B and the Espline Influenza A+B had comparable sensitivity (63%) and were the most sensitive among the four assays evaluated.


Subject(s)
Antigens, Viral/analysis , Clinical Laboratory Techniques/methods , Influenza A Virus, H1N1 Subtype/isolation & purification , Influenza A Virus, H3N2 Subtype/isolation & purification , Influenza, Human/virology , Nasopharynx/virology , Virology/methods , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Humans , Immunoassay/methods , Infant , Male , Middle Aged , Sensitivity and Specificity , Young Adult
5.
J Int Med Res ; 38(1): 242-52, 2010.
Article in English | MEDLINE | ID: mdl-20233536

ABSTRACT

This study was designed to assess the clinical effect of a home-based telephone intervention in Chinese heart failure patients. A total of 550 Chinese heart failure patients were enrolled into either (i) a group that received the usual standard of care (UC group); or (ii) a group that received a home-based heart failure centre management programme using nursing specialist-led telephone consultations (HFC group). The impact of the home-based intervention on admission rate, admission length and medical costs over 6 months was measured. Although the mean left ventricular ejection fraction in HFC patients was 29.3% compared with 34.8% in UC patients, the home-based intervention resulted in a significantly lower all-cause admission rate per person (HFC 0.60 +/- 0.77 times/person; UC 0.96 +/- 0.85 times/person), a shorter all-cause hospital stay (reduced by 8 days per person) and lower total 6-month medical costs (reduced by US$2682 per patient). These results suggest that the home-based intervention with nursing specialist-led telephone consultations may improve the clinical outcome and provide cost-savings for Chinese patients with heart failure.


Subject(s)
Health Care Costs/statistics & numerical data , Heart Failure, Systolic/economics , Heart Failure, Systolic/nursing , Home Care Services, Hospital-Based/economics , Outcome Assessment, Health Care/economics , Asian People , Case-Control Studies , Cost-Benefit Analysis , Female , Follow-Up Studies , Humans , Length of Stay , Male , Middle Aged , Patient Readmission , Prospective Studies , Survival Rate , Telemedicine , Telephone
6.
J Int Med Res ; 36(5): 1077-84, 2008.
Article in English | MEDLINE | ID: mdl-18831904

ABSTRACT

This study evaluated the efficacy and safety of use of the Angio-Seal vascular closure device deployment for early ambulation (2 h) after elective percutaneous coronary intervention in 143 consecutive patients receiving either intravenous low-dose enoxaparin (0.5 mg/kg) or unfractionated heparin (UFH). The initial success rate of Angio-Seal(trade mark) deployment was 98.6%, with no significant difference between the UFH group (98.9%) and the enoxaparin group (98.0%). In-hospital and clinic outcomes were evaluated in the 141 patients with successful Angio-Seal deployment. During hospitalization, there were no deaths, myocardial infarction, urgent target vessel revascularization or bleeding events in either group; three patients in the UFH group and none in the enoxaparin group had minor vascular complications (differences not significant). In clinic follow-up, two patients in the UFH group and none in the enoxaparin group had major vascular complications (differences not significant). Routine use of the Angio-Seal(trade mark) for early ambulation in patients receiving intravenous low-dose enoxaparin compared with UFH provides promising efficacy and safety for daily practice.


Subject(s)
Angioplasty, Balloon, Coronary , Anticoagulants/therapeutic use , Early Ambulation , Enoxaparin/therapeutic use , Hemostatic Techniques , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Femoral Artery/surgery , Hemostatic Techniques/instrumentation , Heparin/analogs & derivatives , Heparin/therapeutic use , Humans , Male , Middle Aged , Treatment Outcome
7.
Int J Clin Pract ; 62(4): 555-61, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18067561

ABSTRACT

BACKGROUND: In ST-segment elevation acute myocardial infarction (STEMI), dislodgement of thrombus within the culprit artery during primary percutaneous coronary intervention (PCI) may cause distal embolisation and impaired myocardial reperfusion. Clinical results of thromboembolic protection strategies have been controversial. We conducted this study to investigate whether the benefit of thrombus removal is time dependent. METHODS: Seventy-four STEMI patients within 12 h from onset were randomised to receive either primary PCI with initial thrombosuction (IT) or standard strategy. Results were analysed in subgroups according to the onset-to-lab time intervals (subgroup 1: 0-240 min, subgroup 2: 241-480 min and subgroup 3: 481-720 min). RESULTS: The primary end-points were improvements in thrombolysis in myocardial infarction flow (DeltaTIMI) and myocardial blush grade (DeltaMBG) postprocedure. Better DeltaTIMI (2.2 +/- 1.1 vs. 1.5 +/- 1.3, p = 0.014) and DeltaMBG (2.3 +/- 1.1 vs. 1.0 +/- 1.5, p < 0.001) were observed in IT patients, compared with standard PCI patients. In onset-to-lab time subgroup analysis, the difference between IT and standard PCI is significant only in subgroup 2 (DeltaTIMI 2.6 +/- 1.0 vs. 1.3 +/- 1.2, p = 0.007; DeltaMBG 2.6 +/- 0.9 vs. 1.0 +/- 1.1, p = 0.010), but not in the other two subgroups. CONCLUSIONS: This prospective randomised study shows that primary PCI with IT may improve epicardial flow and myocardial reperfusion in patients with STEMI, and this benefit is the most significant in patients treated within 4-8 h after symptom onset.


Subject(s)
Coronary Thrombosis/therapy , Myocardial Infarction/therapy , Myocardial Reperfusion/methods , Angioplasty, Balloon, Coronary , Female , Humans , Male , Middle Aged , Prospective Studies , Suction/methods , Thrombectomy/methods , Time Factors
9.
Ultrasound Med Biol ; 27(9): 1191-8, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11597359

ABSTRACT

We conducted a study to delineate the alterations in the cyclic changes of myocardial ultrasonic integrated backscatter (IBS) in patients receiving angioplasty for chronic coronary artery disease. Ultrasonic tissue characterization (UTC) and dobutamine stress echocardiography were performed in 43 patients before and 24 h after angioplasty, as well as before the follow-up angiography 3 months later. For segments being normokinetic with ischemic burden, the blunted amplitude and increased nadir deviation of IBS cyclic modulation recovered soon after angioplasty. For dyssynergic segments with contractile reserve, the angioplasty rebuilt the amplitude before the wall motion recovered, but corrected the nadir deviation tardily. In both circumstances, the coronary restenosis abolished the initial restoration. Those nonviable segments persistently revealed large deviations and small weighted amplitudes irrelevant to coronary lesions. The progress of myocardial ischemia, the development of wall motion dyssynergy and, then, the loss of viability, show different patterns of alterations in UTC after alleviating coronary obstructions.


Subject(s)
Angioplasty , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Echocardiography , Myocardial Contraction/physiology , Aged , Chronic Disease , Coronary Angiography , Coronary Artery Disease/physiopathology , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/physiopathology , Cross-Sectional Studies , Echocardiography, Stress , Female , Humans , Male , Middle Aged , Myocardial Ischemia/diagnostic imaging , Myocardial Ischemia/physiopathology
10.
Nucl Med Commun ; 22(9): 1015-9, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11505211

ABSTRACT

Progressive heterogeneity of thallium-201 single photon emission computed tomography (Tl-201 SPECT) in heart transplant recipients has been documented in Caucasians. However, in Chinese heart transplant recipients, a lower incidence of transplant coronary artery disease (CAD) has been noted than in Western transplant recipients. In this study, we examine whether heterogeneity of Tl-201 SPECT exists in Chinese transplant recipients. Dobutamine Tl-201 SPECT was performed in 40 heart transplant recipients and the inhomogeneity scores were calculated. The difference between the scores of transplant recipients surviving less than 12 months and those of control subjects were not statistically significant. One year after transplantation, the inhomogeneity score increased progressively. The scores of transplant patients in the second and third years after transplant were similar to those of single-vessel CAD patients. Three years after transplant the scores were greatly increased. Thus, our data suggest that the progressive nature of graft vasculopathy also exists in Chinese heart transplant recipients. The progressive Tl-201 abnormalities may be one of the early signs of graft vasculopathy.


Subject(s)
Coronary Circulation , Dobutamine , Heart Transplantation , Thallium Radioisotopes , Tomography, Emission-Computed, Single-Photon , Adolescent , Adult , Female , Humans , Male , Middle Aged
11.
Ultrasound Med Biol ; 27(7): 925-31, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11476926

ABSTRACT

To evaluate the accuracy of various types of wall motion response during dobutamine echocardiography (DE) in predicting functional recovery after revascularization, we studied 30 patients with stable coronary disease and left ventricular dysfunction by simultaneous DE and (201)Tl reinjection SPECT. Among 480 segments (16 segments/patient), 199 had abnormal wall motion at baseline and 167 were revascularized. The predictive value for recovery of function was 72% for a biphasic response, 61% for sustained improvement, 77% for worsening, and 27% for no change (p < 0.01 vs. each). Biphasic response had a sensitivity of 40% and specificity of 85%. Combining biphasic, sustained improvement and worsening responses, the sensitivity, specificity and accuracy were 76%, 65% and 71%, respectively. For (201)Tl SPECT, they were 90%, 65% and 78%, respectively. Thus, a biphasic response alone is of low sensitivity. Combination of biphasic, sustained improvement and worsening responses gives an accuracy rate comparable to that of (201)Tl reinjection SPECT in assessing functional recovery.


Subject(s)
Coronary Disease/diagnostic imaging , Dobutamine , Echocardiography , Myocardial Revascularization , Thallium Radioisotopes , Tomography, Emission-Computed, Single-Photon , Ventricular Dysfunction, Left/diagnostic imaging , Adult , Aged , Coronary Disease/therapy , Female , Humans , Male , Middle Aged , Myocardial Contraction , Predictive Value of Tests , Prognosis , Rest , Sensitivity and Specificity , Ventricular Dysfunction, Left/complications
12.
J Formos Med Assoc ; 100(2): 83-8, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11393106

ABSTRACT

BACKGROUND AND PURPOSE: Ischemic patterns in patients with syndrome X are thought to differ from those in patients with myocardial bridge, because the mechanisms of coronary flow reduction in these two diseases are different. The aim of this study was to compare the ischemic patterns in patients with syndrome X and those with myocardial bridge through the use of dobutamine stress echocardiography (DSE) and stress thallium-201 single-photon emission computed tomography (SPECT). METHODS: Twenty-six patients with typical angina and stress-induced ST-segment depression were enrolled. All patients underwent coronary angiography, DSE, and stress thallium-201 SPECT within 7 days after enrollment. RESULTS: Of the 26 patients enrolled, 10 had myocardial bridge of the left anterior descending artery and 16 had syndrome X. Among patients with myocardial bridge, myocardial dyssynergy was found by DSE in five patients and reversible or fixed thallium-201 perfusion defects were found in four. Seven patients with myocardial bridge had reverse redistribution patterns on thallium-201 scintigraphy. In the 16 patients with syndrome X, myocardial dyssynergy was found by DSE in only one patient (p = 0.018 vs myocardial bridge group) and reversible or fixed thallium-201 perfusion defects were found in nine (p > 0.05 vs myocardial bridge group). Four patients with syndrome X had reverse redistribution patterns on thallium-201 scintigraphy. The resting left ventricular end-diastolic pressure was higher in patients with myocardial bridge than in those with syndrome X (17 +/- 4 vs 12 +/- 5 mm Hg, p = 0.02). CONCLUSIONS: The most common ischemic patterns in patients with syndrome X were chest pain and stress-induced ST-segment depression, followed by myocardial perfusion defects. Dobutamine-induced dyssynergy was rare. Left ventricular end-diastolic pressure elevation and dobutamine-induced wall motion abnormalities were more common in patients with myocardial bridge than in those with syndrome X.


Subject(s)
Dobutamine , Echocardiography , Microvascular Angina/diagnosis , Myocardial Infarction/diagnosis , Myocardial Ischemia/diagnosis , Thallium Radioisotopes , Tomography, Emission-Computed, Single-Photon , Adult , Aged , Female , Humans , Male , Middle Aged
13.
Ultrasound Med Biol ; 27(2): 171-9, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11316525

ABSTRACT

Cardiomyocyte hypertrophy and interstitial fibrin deposition develop in cardiac allografts and contribute to the functional changes of transplanted hearts. We hypothesized that integrated backscatter (IBS) can detect these myocardial changes. A total of 32 heart transplant recipients with either no or mild acute rejection (International Society of Heart and Lung Transplantation grade IA) were enrolled in this study. IBS data of myocardium were collected immediately before simultaneous dobutamine stress echocardiography (DSE) and (201)thallium imaging. Coronary angiography and endomyocardial biopsy were also performed. Coronary angiography showed diffuse narrowing in 1 patient who also had abnormal results of IBS, DSE, and thallium results. In the other 31 patients with patent coronary arteries, there were 3 patients (10%) with abnormal DSE results, 19 patients (61%) with abnormal IBS patterns, and 16 patients (52%) with reversible thallium perfusion defects. Of the patients, 44% had cardiomyocyte hypertrophy and 56% interstitial fibrin deposition. There were significant differences in the prevalence of (201)thallium perfusion defects and serum cyclosporine levels between patients with and without abnormal IBS patterns. Pathologic changes were also associated with abnormal IBS patterns (p = 0.01). However, there was no association between abnormal IBS and DSE results. By multiple logistic regression analysis, the abnormal IBS patterns were associated inversely with serum cyclosporine level (p = 0.028). In conclusion, abnormal IBS patterns are associated significantly with perfusion heterogeneity and pathologic changes in heart transplant recipients without evident acute myocardial rejection. There is no association between abnormal IBS patterns and dobutamine-induced dyssynergy in these patients. IBS provides a noninvasive approach for detection of myocardial changes in transplanted hearts without evident acute rejection.


Subject(s)
Coronary Disease/diagnostic imaging , Heart Transplantation , Cardiac Catheterization , Cardiotonic Agents , Chi-Square Distribution , Coronary Disease/physiopathology , Dobutamine , Echocardiography , Exercise Test , Female , Heart Transplantation/adverse effects , Humans , Logistic Models , Male , Middle Aged , Observer Variation , Thallium Radioisotopes , Tomography, Emission-Computed, Single-Photon
14.
Pacing Clin Electrophysiol ; 24(11): 1596-601, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11816627

ABSTRACT

At 1:47 AM on September 21, 1999, the middle part of Taiwan was struck by a major earthquake measuring 7.3 on the Richter scale. It has been shown that the mental stress caused by an earthquake could lead to a short- or long-term increase in frequency of cardiac death probably through activation of the sympathetic nervous system. The aim of this study was to investigate the effects of emotional stress on the autonomic system during an actual earthquake. Fifteen patients receiving a 24-hour Holter ECG study starting from 10+/-4 hours before the onset of the earthquake were included for the analysis of time- and frequency-domains of heart rate variability (HRV) at several time periods. A 24-hour Holter study recorded 2-6 months before the earthquake in 30 age- and sex-matched subjects served as the control group. Heart rate and the low frequency (LF) to high frequency (HF) ratio increased significantly after the earthquake and were attributed mainly to the withdrawal of the high frequency component (parasympathetic activity) of HRV. Sympathetic activation was blunted in elderly subjects > 60 years old. The concomitant ST-T depression observed in the Holter study correlated with a higher increment of LF as compared to HF components. The changes observed in HRV recovered completely 40 minutes following the earthquake. The derangement of HRV results from the withdrawal of the parasympathetic component and the arousal of sympathetic activity by the stressful earthquake. However, this autonomic derangement returned towards normal 40 minutes following the earthquake.


Subject(s)
Disasters , Heart Rate/physiology , Stress, Psychological/physiopathology , Sympathetic Nervous System/physiology , Adult , Aged , Angina Pectoris/etiology , Electrocardiography, Ambulatory , Female , Humans , Life Change Events , Male , Middle Aged , Myocardial Infarction/etiology , Stress, Psychological/complications , Time Factors
15.
Am J Cardiol ; 86(3): 293-8, 2000 Aug 01.
Article in English | MEDLINE | ID: mdl-10922436

ABSTRACT

Previous studies have shown that ultrasonic integrated backscatter is valuable in characterizing stunned myocardium. Recent investigations have demonstrated that resting cardiac cycle-dependent variation of integrated backscatter closely paralleled the contractile reserve in patients with chronic left ventricular ischemic dysfunction. The purpose of this study was to validate whether ultrasonic tissue characterization (UTC) compared with dobutamine stress echocardiography (DSE) and thallium-201 stress-reinjection single-photon emission computed tomography (Tl-SPECT) could predict reversible myocardial dyssynergy in patients with chronic coronary artery disease. Forty-eight patients with stable coronary artery disease underwent UTC, DSE, and Tl-SPECT simultaneously before successful coronary revascularization and were followed up with echocardiograms at rest >3 months later. Among the 58 investigated segments, the weighted amplitude, a composite parameter derived from the integrated backscatter power curve, was larger for those groups with greater functional recovery (p <0.001). For the persistent akinetic segments, the weighted amplitudes were small with large deviations of the nadir ratios that represented the asynchrony between the intramural contractile events and the global systole. Using the cut-off value 2.0 of the weighted amplitude, the sensitivity and specificity for predicting functional improvement after revascularization were both 82.8% (kappa = 0.66) and comparable to the sensitivity and specificity of DSE and Tl-SPECT. UTC, delineating the myocardial physical state and intramural contraction, can be a novel approach in predicting functional improvement of chronic dyssynergy after revascularization.


Subject(s)
Cardiotonic Agents , Coronary Disease/therapy , Dobutamine , Echocardiography , Myocardial Contraction/physiology , Myocardial Revascularization , Tomography, Emission-Computed, Single-Photon , Ventricular Dysfunction, Left/diagnosis , Adult , Aged , Coronary Disease/diagnosis , Coronary Disease/physiopathology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Predictive Value of Tests , Treatment Outcome , Ventricular Dysfunction, Left/physiopathology
16.
Cardiology ; 93(1-2): 113-20, 2000.
Article in English | MEDLINE | ID: mdl-10894916

ABSTRACT

This study was designed to quantify the blood stagnation in left atrial appendages (LAA) of patients with rheumatic mitral stenosis, and to stratify the risk of spontaneous echo contrast (SEC) for thrombus formation. A total of 45 patients were enrolled in this study. Thirty of the 45 patients had rheumatic mitral stenosis. All the above patients were evaluated for LAA contractility by transesophageal echocardiography. Acoustic density of the stagnant blood was assessed using the integrated backscatter (IBS) mode. Multivariate linear regression analysis showed that the significant independent variables determining relative IBS in LAA were the mitral valve area (p = 0.02) and the atrial fibrillation rhythm (p = 0.0003). In patients with mitral stenosis, the IBS in LAA correlated well with the presence of thrombus (p = 0.004) and SEC (p = 0.002). Using the relative IBS in LAA with 6.8 dB as the cutoff value, the diagnostic sensitivity, specificity, positive predictive value, negative predictive value and accuracy of SEC formation in LAA was 83, 86, 95, 60 and 83%, respectively. Using the relative IBS in LAA with 10.0 dB as the cutoff value, the diagnostic sensitivity, specificity, positive predictive value, negative predictive value and accuracy of SEC with thrombus formation in LAA was 80, 80, 67, 89 and 80%, respectively. In conclusion, the blood stasis in LAA can be objectively quantified using IBS. Utilizing different cutoff values, the acoustic densitometry in LAA enables identification of stagnant blood which represents a risk for the development of either SEC only or SEC with thrombus formation.


Subject(s)
Atrial Appendage , Echocardiography, Transesophageal , Mitral Valve Stenosis/complications , Rheumatic Heart Disease/complications , Risk Assessment/methods , Thrombosis/diagnostic imaging , Adolescent , Adult , Aged , Diagnosis, Differential , Female , Heart Diseases/diagnostic imaging , Heart Diseases/etiology , Heart Diseases/physiopathology , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/physiopathology , Myocardial Contraction , Reproducibility of Results , Rheumatic Heart Disease/diagnostic imaging , Rheumatic Heart Disease/physiopathology , Thrombosis/etiology , Thrombosis/physiopathology
17.
Ultrasound Med Biol ; 26(2): 341-6, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10722924

ABSTRACT

The abnormal spatial distribution of intraventricular flow is superior to clinical and two-dimensional (2-D) echocardiographic variables in predicting left ventricular thrombosis after myocardial infarction. Echocardiography was prospectively performed in 79 patients within 72 h after anterior wall myocardial infarction onset and repeated before discharge. The apical rotating flow pattern in color flow map was recognized as abnormal. By power Doppler echocardiography, the moving blood could generate speckle tracking images to delineate the intraventricular flow. A swirling flow pattern indicating the compartmentalization of left ventricular blood flow with some blood stagnant in the apical dyssynergic area was identified. The flow pattern shown by the speckle tracking image was superior to the color-flow map in correlating with left ventricular thrombosis. It implicated that the more the detail in which we can describe the blood flow pathway, the more information we can realize.


Subject(s)
Echocardiography, Doppler, Pulsed , Heart Ventricles/diagnostic imaging , Myocardial Infarction/physiopathology , Thrombosis/physiopathology , Adult , Aged , Blood Flow Velocity , Cardiac Catheterization , Diagnosis, Differential , Female , Heart Diseases/diagnostic imaging , Heart Diseases/etiology , Heart Diseases/physiopathology , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Myocardial Infarction/complications , Myocardial Infarction/diagnostic imaging , Odds Ratio , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Thrombosis/diagnostic imaging , Thrombosis/etiology , Ventricular Pressure
18.
Ultrasound Med Biol ; 26(9): 1413-20, 2000 Nov.
Article in English | MEDLINE | ID: mdl-11179615

ABSTRACT

Ultrasonic tissue characterization with integrated backscatter is an objective method to quantitatively define the physical state of the myocardium. To determine if backscatter imaging during inotropic stimulation could be used objectively to determine the myocardial viability and ischemia in patients with ischemic heart disease, the backscatter changes were examined in 23 patients with myocardial infarction during dobutamine stress two-dimensional (2-D) echocardiography. Coronary angiography was performed within 1 to 2 days after the stress test. The results of this study demonstrated that changes in backscatter variability correlated significantly with the wall motion changes in stress echocardiography during dobutamine infusion (p < 0.0001). In addition, it was shown that the backscatter changes were significantly different in various types of myocardial tissue. In 23 healthy control segments, the ultrasonic backscatter variability was preserved and unchanged during inotropic stimulation (p = NS). In 15 viable infarct zones, restoration or an increase in backscatter variability during low-dose dobutamine infusion was noted, this being lost when ischemia developing during high-dose dobutamine infusion (p < 0.01). In 9 nonviable infarct zones, the phase-weighted variation was usually < or = 0 and did not change significantly during inotropic stimulation, regardless of the patency of the infarct-related arteries. In 15 remote ischemic myocardial zones, the backscatter variability was preserved at the baseline level, did not change during low-dose dobutamine infusion, but decreased significantly during high-dose dobutamine stress (p < 0.01). In conclusion, dobutamine stress tissue characterization could offer an objective approach for the detection of myocardial viability and ischemia, and might be a useful adjunct to the conventional stress echocardiography.


Subject(s)
Cardiotonic Agents , Dobutamine , Echocardiography , Myocardial Contraction/drug effects , Myocardial Infarction/diagnostic imaging , Coronary Angiography , Electrocardiography , Female , Humans , Male , Middle Aged , Myocardial Infarction/physiopathology , Reproducibility of Results , Signal Processing, Computer-Assisted , Stimulation, Chemical
19.
Cardiology ; 94(3): 200-7, 2000.
Article in English | MEDLINE | ID: mdl-11279327

ABSTRACT

BACKGROUND AND PURPOSE: Previous studies have shown that left ventricular systolic asynchrony affects both the relaxation and filling phases of diastole. The purpose of this study was to delinate how the anterior wall dyssynergy influenced the intraventricular flow redistribution patterns during the isovolumic relaxation (IVR) period, which delineated the changes in diastolic suction performance and, therefore, determined the significant Doppler flow variables for predicting left ventricular filling pressure. METHODS: Seventy-three patients with anterior wall myocardial infarction and dyssynergy were enrolled. Those who exhibited the whole IVR intraventricular flow redistributing toward the mitral apparatus, which indicated the reverse physiologic intraventricular pressure gradient in early diastole, were classified as group B, otherwise, as group A. The Doppler echocardiographic variables of mitral inflow were correlated with the left ventricular end-diastolic pressures (LVEDP). RESULTS: With lower ejection fraction rate and more apical dyssynergy, the group B patients had much slower mitral flow propagation. For group A patients, the independent determinants for LVEDP were the ratio of mitral flow propagation rate to peak velocity in early diastole, the early mitral flow deceleration time and the IVR time, all occurring in early diastole. In contrast, the only independent determinant for LVEDP in group B patients was the ratio of mitral peak flow velocity in early diastole to that in late diastole. CONCLUSIONS: The intraventricular IVR flow patterns could delineate how the left ventricular systolic dyssynergy influenced the diastolic process, and determine which echocardiographic variables were more useful for predicting LVEDP in patients with anterior wall myocardial infarction.


Subject(s)
Echocardiography, Doppler, Color , Myocardial Infarction/diagnostic imaging , Stroke Volume/physiology , Ventricular Function, Left/physiology , Ventricular Pressure/physiology , Adult , Aged , Blood Flow Velocity/physiology , Cardiac Catheterization , Diastole/physiology , Female , Humans , Male , Middle Aged , Myocardial Infarction/physiopathology
20.
Ultrasound Med Biol ; 25(8): 1185-93, 1999 Oct.
Article in English | MEDLINE | ID: mdl-10576261

ABSTRACT

Alterations of ultrasonic backscatter parameters have been evident in humans with myocardial infarction or ischemia. The backscatter variability could be restored in ischemic or stunned myocardium after reperfusion. The aims of this study were to determinate changes in regional myocardial ultrasonic backscatter during intra-aortic balloon counterpulsation (IABP) support in patients with acute myocardial infarction (AMI), and to evaluate whether backscatter imaging could be a functional guide of IABP support. A total of 9 patients with AMI were investigated during IABP support with a two-dimensional (2-D) ultrasonic backscatter imaging approach for parasternal short-axis view. Coronary angiography was performed in 6 of the 9 patients. A total of 21 vessel territories were studied in different modes of IABP support: 1:1, 1:2 and standby. Restoration of cyclic variation of backscatter after IABP support was demonstrated in 10 vessel territories. Failure of restoration of cyclic variation of backscatter after IABP support was noted in 6 vessel territories with severe coronary lesions (total or nearly total occlusion) or scar tissue. No changes of the ultrasonic backscatter were found in nonischemic vessel territories with patent coronary arteries or TIMI III coronary flow. In addition, the wall motion score did not change significantly with different IABP support. These results suggest that IABP could restore the cyclic variation of backscatter in ischemic myocardium. Myocardial anisotropy may play an influential role in the alterations of ultrasonic backscatter. We propose that ultrasonic backscatter could be a noninvasively functional guide of IABP use in patients with AMI.


Subject(s)
Echocardiography , Intra-Aortic Balloon Pumping , Myocardial Infarction/diagnostic imaging , Aged , Coronary Angiography , Female , Humans , Male , Myocardial Contraction , Myocardial Infarction/therapy , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...