Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 223
Filter
1.
PLoS One ; 18(7): e0288664, 2023.
Article in English | MEDLINE | ID: mdl-37450555

ABSTRACT

The reliability of surface electromyography (sEMG) has not been adequately demonstrated in the equine literature and is an essential consideration as a methodology for application in clinical gait analysis. This observational study investigated within-session, intra-subject (stride-to-stride) and inter-subject reliability, and between-session reliability of normalised sEMG activity profiles, from triceps brachii (triceps), latissimus dorsi (latissimus), longissimus dorsi (longissimus), biceps femoris (biceps), superficial gluteal (gluteal) and semitendinosus muscles in n = 8 clinically non-lame horses during in-hand trot. sEMG sensors were bilaterally located on muscles to collect data during two test sessions (session 1 and 2) with a minimum 24-hour interval. Raw sEMG signals from ten trot strides per horse and session were DC-offset removed, high-pass filtered (40 Hz), full-wave rectified, and low-pass filtered (25 Hz). Signals were normalised to peak amplitude and percent stride before calculating intra- and inter-subject ensemble average sEMG profiles across strides for each muscle and session. sEMG profiles were assessed using waveform similarity statistics: the coefficient of variation (CV) to assess intra- and inter-subject reliability and the adjusted coefficient of multiple correlation (CMC) to evaluate between-session reliability. Across muscles, CV data revealed that intra-horse sEMG profiles within- and between-sessions were comparatively more reliable than inter-horse profiles. Bilateral gluteal, semitendinosus, triceps and longissimus (at T14 and L1) and right biceps showed excellent between-session reliability with group-averaged CMCs > 0.90 (range 0.90-0.97). Bilateral latissimus and left biceps showed good between-session reliability with group-averaged CMCs > 0.75 (range 0.78-0.88). sEMG profiles can reliably describe fundamental muscle activity patterns for selected equine muscles within a test session for individual horses (intra-subject). However, these profiles are more variable across horses (inter-subject) and between sessions (between-session reliability), suggesting that it is reasonable to use sEMG to objectively monitor the intra-individual activity of these muscles across multiple gait evaluation sessions at in-hand trot.


Subject(s)
Muscle, Skeletal , Horses , Animals , Reproducibility of Results , Muscle, Skeletal/physiology , Electromyography/methods
2.
J Small Anim Pract ; 63(7): 542-549, 2022 07.
Article in English | MEDLINE | ID: mdl-35137955

ABSTRACT

OBJECTIVES: To describe the occurrence, management and outcome of proximal metaphyseal curvilinear tibial fractures in skeletally immature dogs. MATERIALS AND METHODS: A multi-centre retrospective review was conducted, searching for skeletally immature dogs presenting with proximal metaphyseal curvilinear tibial fractures between January 2009 and September 2020. Signalment, fracture description and case management data were retrieved. Outcome was assessed by retrospectively evaluating follow-up radiographs, hospital records and an owner questionnaire. RESULTS: Twenty-five dogs met the inclusion criteria. All but one fracture was a result of minimal trauma. Twenty fractures were managed with internal fixation, two with external fixation and three conservatively. All 25 fractures healed. Eight major complications occurred in seven of 25 (28%) dogs. Twelve minor complications occurred in 10 of 25 (40%) dogs. Owner questionnaire data were available for 12 of 25 dogs; 11 of 12 were reported as having full function and one of 12 as having acceptable function at the time of questioning (median 34.5 months following presentation). At final follow-up, either by clinical examination or owner questionnaire, full function was achieved in 22 of 25 patients and acceptable function in three of 25. CLINICAL SIGNIFICANCE: This study reported a series of proximal metaphyseal tibial fractures in skeletally immature dogs. The most common fixation method was internal fixation, which frequently resulted in full limb function at final follow-up. Owners reported outcome as fully functional in all dogs that underwent surgery at first presentation and had owner follow-up available, though positive outcomes may have been affected by participation bias.


Subject(s)
Dog Diseases , Tibial Fractures , Animals , Dog Diseases/diagnostic imaging , Dog Diseases/surgery , Dogs , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/veterinary , Radiography , Retrospective Studies , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery , Tibial Fractures/veterinary , Treatment Outcome
4.
J Small Anim Pract ; 60(8): 463-470, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31006864

ABSTRACT

OBJECTIVES: To describe the range of motion and clinical stability of the feline shoulder following experimental injury and repair using a prosthetic suture technique. MATERIALS AND METHODS: Eighteen feline cadaveric thoracic limbs were randomly allocated into three groups: medial injury, lateral injury or bilateral injury. Joint range of motion and clinical stability in all directions was recorded before and after specific anatomic structures were sectioned and following surgical repair using a prosthetic suture technique. Results were compared between intact, injured and repaired limbs for each injury type. RESULTS: There was a significant difference in joint range of motion in specific limb directions between intact and injured joints and between injured and repaired joints. There was no difference in joint range of motion between intact and repaired joints. Four of six medially injured joints were deemed clinically stable and five of six laterally injured joints were deemed clinically stable. All bilaterally injured joints were deemed unstable. CLINICAL SIGNIFICANCE: The relative contributions of shoulder stabilisers to joint range of motion and clinical stability provide a reference for clinical cases with suspected shoulder instability. The prosthetic suture repair technique described was effective at returning the shoulder joint to a normal range of motion in this ex vivo model.


Subject(s)
Joint Instability/veterinary , Shoulder , Animals , Biomechanical Phenomena , Cadaver , Cats , Ligaments , Prostheses and Implants , Range of Motion, Articular
5.
J Electromyogr Kinesiol ; 43: 28-40, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30219734

ABSTRACT

High-pass filtering (HPF) is a fundamental signal processing method for the attenuation of low-frequency noise contamination, namely baseline noise and movement artefact noise, in human surface electromyography (sEMG) research. Despite this, HPF is largely overlooked in equine sEMG research, with many studies not applying, or failing to describe, the application of HPF. An optimal HPF cut-off frequency maximally attenuates noise while minimally affecting sEMG signal power, but this has not been investigated for equine sEMG signals. The aim of this study was to determine the optimal cut-off frequency for attenuation of low-frequency noise in sEMG signals from the Triceps Brachii and Biceps Femoris of 20 horses during trot and canter. sEMG signals were HPF with cut-off frequencies ranging from 0 to 80 Hz and were subjected to power spectral analysis and enveloped using RMS to calculate spectral peaks, indicative of motion artefact, and signal loss, respectively. Processed signals consistently revealed a low-frequency peak between 0 and 20 Hz, which was associated with motion artefact. Across all muscles and gaits, a 30-40 Hz cut-off fully attenuated the low-frequency peak with the least amount of signal loss and was therefore considered optimal for attenuating low-frequency noise from the sEMG signals explored in this study.


Subject(s)
Electromyography/methods , Gait/physiology , Horses/physiology , Locomotion/physiology , Muscle, Skeletal/physiology , Animals , Female , Male , Signal Processing, Computer-Assisted
6.
Sci Rep ; 7(1): 15685, 2017 Nov 23.
Article in English | MEDLINE | ID: mdl-29170446

ABSTRACT

Our recent report detailing the health status of cloned sheep concluded that the animals had aged normally. This is in stark contrast to reports on Dolly (first animal cloned from adult cells) whose diagnoses of osteoarthritis (OA) at 5½ years of age led to considerable scientific concern and media debate over the possibility of early-onset age-related diseases in cloned animals. Our study included four 8-year old ewes derived from the cell line that gave rise to Dolly, yet none of our aged sheep showed clinical signs of OA, and they had radiographic evidence of only mild or, in one case, moderate OA. Given that the only formal record of OA in Dolly is a brief mention of a single joint in a conference abstract, this led us to question whether the original concerns about Dolly's OA were justified. As none of the original clinical or radiographic records were preserved, we undertook radiographic examination of the skeletons of Dolly and her contemporary clones. We report a prevalence and distribution of radiographic-OA similar to that observed in naturally conceived sheep, and our healthy aged cloned sheep. We conclude that the original concerns that cloning had caused early-onset OA in Dolly were unfounded.


Subject(s)
Cloning, Organism/adverse effects , Osteoarthritis/epidemiology , Age Factors , Age of Onset , Animals , Body Remains/diagnostic imaging , Cell Line , Cloning, Organism/methods , Female , Osteoarthritis/diagnostic imaging , Osteoarthritis/genetics , Prevalence , Sheep , Skeleton/diagnostic imaging
7.
Vet J ; 227: 49-57, 2017 Sep.
Article in English | MEDLINE | ID: mdl-29031331

ABSTRACT

The development of safety and quality standards for equestrian surfaces needs to be based on objective, repeatable measurements which allow comparisons between surfaces. These measurements should incorporate the assessment of surface performance by riders. This study provides data from objective and subjective assessment of functional properties of high-level show jumping competition and warm-up arenas. Twenty-five arenas in nine international show jumping events were evaluated by mechanical in-situ testing with a surface tester, rider assessments using visual analogue scales (198 riders provided 749 arena evaluations), descriptions of arena constructions and by laboratory tests of surface material. Mixed models were used to present subjective evaluation of rider perception of the functional properties for each arena while controlling for rider and event. The association between objective and subjective assessments were also explored creating mixed models, controlling for rider and event. Mechanical measurements of impact firmness, and to a lesser extent cushioning and grip, had a significant positive association with the riders' perception. Responsiveness as assessed by the Orono biomechanical surface tester (OBST) was negatively associated with the riders' perceptions, which suggests riders and the OBST had different concepts of this functional property and that further developments of the OBST might be necessary. Objectively measured uniformity showed no useful association with riders' perception. Even though arena assessments were made by top level riders, a substantial inter-rider variation was demonstrated.


Subject(s)
Animal Welfare , Horses , Sports , Animal Welfare/standards , Animals , Biomechanical Phenomena , Humans , Surveys and Questionnaires
8.
Vet J ; 221: 30-33, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28283077

ABSTRACT

In this study, sagittal plane ground reaction forces (GRFs) in ridden elite dressage horses performing 'collected trot' and in 'passage' over ground were determined. In-ground force plates captured GRF data from four Dutch Warmblood and four Lusitano horses ridden by their trainers. At least three stance phases were analysed for forelimbs and hind limbs per horse. The variables extracted were vertical and longitudinal (braking, propulsive) force maxima, their times of occurrence and the respective impulses for forelimbs and hind limbs. Lusitanos had lower vertical impulses than Dutch Warmbloods in collected trot. Across all horses, passage had larger vertical impulses than collected trot in the forelimbs and hind limbs. Propulsive impulse increased in the hind limbs in passage. Prolonged stance durations in passage contributed to higher vertical impulses that are needed to increase the vertical excursions of the centre of mass.


Subject(s)
Horses/physiology , Locomotion/physiology , Animals , Biomechanical Phenomena , Forelimb/physiology , Gait , Hindlimb/physiology
9.
Equine Vet J ; 49(5): 688-691, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28117488

ABSTRACT

BACKGROUND: Previous studies have validated methods for determining kinematic gait events using threshold-based techniques. However, a simple method that can be successfully applied to walk, trot and canter is yet to be identified. OBJECTIVES: To develop a simple kinematic method to identify the timing of hoof contact (hoof-on), peak vertical force and lift off (hoof-off), which can be applied in walk, trot and canter. STUDY DESIGN: In vivo method authentication study. METHODS: Horses (n = 3) were ridden in walk, trot and canter down a runway on which four force plates were arranged linearly. Three-dimensional forces were recorded at a sampling rate of 960 Hz and were synchronised with a 10-camera motion analysis system sampling at 120 Hz. Events identified from vertical ground reaction force (GRFz) data were hoof-on (GRFz>50N), peak vertical force (GRFzpeak ) and hoof-off (GRFz<50N). Kinematic identification of hoof-on and hoof-off events was based on sagittal planar angles of the fore- and hindlimbs. Peak metacarpophalangeal (MCP)/metatarsophalangeal (MTP) joint extension was used to assess the time of GRFzpeak . The accuracy (mean) and precision (s.d.) of time differences between kinetic and kinematic events were calculated for fore- and hindlimbs at each gait. RESULTS: Hoof-off was determined with better accuracy (range: -3.94 to 8.33 ms) and precision (range: 5.43-11.39 ms) than hoof-on across all gaits. Peak MCP angle (range: 5.83-19.65 ms) was a more precise representation of GRFzpeak than peak MTP angle (range: 11.49-67.75 ms). MAIN LIMITATIONS: The sample size was small and therefore further validation is required. The proposed method was tested on a single surface. CONCLUSIONS: This study proposes a simple kinematic method of detecting hoof-on, hoof-off and GRFzpeak at walk, trot and canter. Further work should focus on validating the methodology in a larger number of horses and should extend the method for use on surfaces with varying levels of compliance.


Subject(s)
Gait/physiology , Horses/physiology , Animals , Biomechanical Phenomena , Forelimb , Hindlimb , Hoof and Claw/physiology , Walking
10.
J Small Anim Pract ; 57(9): 472-8, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27467281

ABSTRACT

OBJECTIVE: To describe the clinical findings and management of tibial fractures in cats in which osteosynthesis failed due to plate bending. METHODS: Case records and radiographs of cat tibial fracture repairs from five referral centres were reviewed for signalment and to assess incidence of plate failure by bending. Cats that sustained plate bending following plate or plate-rod fixation were reviewed for fracture configuration, repair method, initial postoperative and postfailure tibial alignment, revision treatment and outcome. RESULTS: The incidence of plate bending in cat fractures managed with plate and plate-rod fixation in the four referral centres where the overall number could be established was 13% (8/60). In the 10 cats in which plates bent, initial fractures were generally oblique or spiral with mild comminution and located in the middle or distal third of the tibia. Mean time to implant failure was 24 days (range 2 to 56 days). Mean tibial valgus angle increased from 12·9° to 30·9° following bending of the plate. Short-term outcome following revision surgery using orthogonal plating or stacked medial plates was favourable with improvement in tibial valgus in all five fractures with follow-up data. CLINICAL SIGNIFICANCE: Plate bending following tibial fracture stabilisation in these 10 cats resulted in tibial valgus deformation. Consideration of plate and/or intramedullary rod selection and application should be given to avoid a plate strain environment that exceeds the yield point of the plate.


Subject(s)
Bone Plates/veterinary , Cats/injuries , Tibial Fractures/veterinary , Animals , Cats/surgery , Female , Fracture Fixation, Intramedullary/veterinary , Male , Prosthesis Failure , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery
12.
Vet Comp Orthop Traumatol ; 28(6): 401-8, 2015.
Article in English | MEDLINE | ID: mdl-26382666

ABSTRACT

OBJECTIVE: To determine whether a lateral suture placed with bone anchors between quasi-isometric points in a cat is superior to a standard fabella-tibial suture for the stabilization of cranial cruciate ligament (CrCL) rupture compared to an intact stifle joint. STUDY DESIGN: Biomechanical cadaveric study. METHODS: Six stifle joints with intact cruciate ligaments from three skeletally mature cats were placed in a loading mounting set and tested with axial loads of 20N and 60N at three different joint angles (75°,130° and 160°). The procedure was repeated with a transected CrCL; a stabilized stifle joint after a combination of three lateral suture techniques (fabella-tibial suture technique [SFT]; femoro-tibial suture technique 1 [FTS-1] and femoro-tibial suture technique 2 [FTS-2]). Radiographic examination of the relative position of the tibia to the fixed femur was compared. RESULTS: Stabilization of the stifle joint with lateral sutures had comparable stability to the intact specimens in the cranio-caudal direction (p = 0.2) but not in the proximo-distal direction for the SFT (p = 0.04) and FTS-2 technique (p = 0.03). There was no significant difference between the three stabilization techniques (p >0.05). CLINICAL SIGNIFICANCE: Lateral sutures placed with bone anchors at quasi-isometric points performed better than SFT and FTS-2 in stabilizing the feline stifle after CrCL rupture in the proximo-distal plane. Biomechanical stability in the cranio-caudal plane after placement of a lateral suture across the feline stifle was similar to the intact CrCL.


Subject(s)
Anterior Cruciate Ligament/pathology , Cats , Femur/surgery , Suture Techniques/veterinary , Tibia/surgery , Animals , Biomechanical Phenomena , Cadaver , Stifle/surgery
13.
Res Sports Med ; 23(3): 289-301, 2015.
Article in English | MEDLINE | ID: mdl-26053415

ABSTRACT

Plyometric training is used by athletes to promote strength and explosive power. However plyometric activities such as depth jumping are associated with a high incidence of injuries. This study examined the influence of minimalist and conventional footwear on the loads experienced by the patellofemoral joint and Achilles tendon. Patellofemoral and Achilles tendon forces were obtained from ten male participants using an eight-camera 3D motion capture system and force platform data as they completed depth jumps in both footwear conditions. Differences between footwear were calculated using paired t-tests. The results show that the minimalist footwear were associated with significantly lower patellofemoral contact force/pressure and also knee abduction moment. It is therefore recommended, based on these observations, that those who are susceptible to knee pain should consider minimalist footwear when performing plyometric training.


Subject(s)
Achilles Tendon/physiology , Patellofemoral Joint/physiology , Plyometric Exercise , Shoes , Adolescent , Adult , Humans , Imaging, Three-Dimensional , Male , Pressure , Video Recording , Weight-Bearing/physiology , Young Adult
14.
J Small Anim Pract ; 56(12): 707-13, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26735776

ABSTRACT

OBJECTIVES: To evaluate inter- and intraobserver reliability of the assessment of computed tomography features commonly used in the identification and classification of medial coronoid process disease and to assess inter- and intraobserver variability in the identification of the percentage ulna sclerosis from single transverse computed tomography images. METHODS: Eight observers, on two occasions, reviewed 84 standardised single transverse computed tomography images acquired at the level of the apex of the medial coronoid process. Observers assessed: medial coronoid process disease, coronoid process fragmentation, osteophytes, sclerosis grade and sclerosis delineation with normal bone defined using a sclerometer. Cohen's kappa and intraclass correlation coefficient were calculated. RESULTS: Inter-observer agreement was fair to moderate for identification of computed tomography changes consistent with medial coronoid process disease, moderate to almost perfect for fragmentation, and moderate for osteophyte detection. Agreement was poor for sclerosis grading. Percentage sclerosis measured with a sclerometer had moderate to almost perfect inter- and intraobserver agreement. CLINICAL SIGNIFICANCE: These findings suggest that subjective assessment of computed tomography images is less repeatable than more quantitative methods.


Subject(s)
Dog Diseases/diagnostic imaging , Elbow Joint/diagnostic imaging , Joint Diseases/veterinary , Animals , Dogs , Female , Forelimb/diagnostic imaging , Joint Diseases/diagnostic imaging , Lameness, Animal/diagnostic imaging , Male , Observer Variation , Sensitivity and Specificity , Tomography, X-Ray Computed/veterinary
16.
Oncogene ; 34(1): 15-26, 2015 Jan 02.
Article in English | MEDLINE | ID: mdl-24292678

ABSTRACT

The HSP90 molecular chaperone plays a key role in the maturation, stability and activation of its clients, including many oncogenic proteins. Kinases are a substantial and important subset of clients requiring the key cochaperone CDC37. We sought an improved understanding of protein kinase chaperoning by CDC37 in cancer cells. CDC37 overexpression in human colon cancer cells increased CDK4 protein levels, which was negated upon CDC37 knockdown. Overexpressing CDC37 increased CDK4 protein half-life and enhanced binding of HSP90 to CDK4, consistent with CDC37 promoting kinase loading onto chaperone complexes. Against expectation, expression of C-terminus-truncated CDC37 (ΔC-CDC37) that lacks HSP90 binding capacity did not affect kinase client expression or activity; moreover, as with wild-type CDC37 overexpression, it augmented CDK4-HSP90 complex formation. However, although truncation blocked binding to HSP90 in cells, ΔC-CDC37 also showed diminished client protein binding and was relatively unstable. CDC37 mutants with single and double point mutations at residues M164 and L205 showed greatly reduced binding to HSP90, but retained association with client kinases. Surprisingly, these mutants phenocopied wild-type CDC37 overexpression by increasing CDK4-HSP90 association and CDK4 protein levels in cells. Furthermore, expression of the mutants was sufficient to protect kinase clients CDK4, CDK6, CRAF and ERBB2 from depletion induced by silencing endogenous CDC37, indicating that CDC37's client stabilising function cannot be inactivated by substantially reducing its direct interaction with HSP90. However, CDC37 could not compensate for loss of HSP90 function, showing that CDC37 and HSP90 have their own distinct and non-redundant roles in maintaining kinase clients. Our data substantiate the important function of CDC37 in chaperoning protein kinases. Furthermore, we demonstrate that CDC37 can stabilise kinase clients by a mechanism that is not dependent on a substantial direct interaction between CDC37 and HSP90, but nevertheless requires HSP90 activity. These results have significant implications for therapeutic targeting of CDC37.


Subject(s)
Cell Cycle Proteins/metabolism , Chaperonins/metabolism , Colonic Neoplasms/metabolism , HSP90 Heat-Shock Proteins/metabolism , Cell Line, Tumor , Cyclin-Dependent Kinase 4/metabolism , Cyclin-Dependent Kinase 6/metabolism , Gene Expression Regulation, Neoplastic , HCT116 Cells , Humans , Mutation , Point Mutation , Protein Binding , Proto-Oncogene Proteins c-raf/metabolism , RNA, Small Interfering/metabolism , Receptor, ErbB-2/metabolism
17.
J Sports Sci ; 32(20): 1914-1923, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25333601

ABSTRACT

Abstract The current investigation aimed to determine whether there are differences in ball velocity and 3D kinematics when performing maximal kicks with the dominant and non-dominant limbs. Seventeen male academy soccer players performed maximal speed place kicks with their dominant and the non-dominant limbs. The 3D kinematics of the lower extremities were obtained using a 10-camera motion capture system operating at 500 Hz. Hip, knee and ankle joint kinematics were quantified in the sagittal, coronal and transverse planes and then contrasted using paired t-tests. Significantly higher ball velocities were obtained with the dominant limb. Foot linear velocity and knee extension velocity at ball contact were also found to be significantly greater in the dominant limb. That reduced ball velocities were observed between kicking limbs highlights the potential performance detriments that may occur when kicking with the non-dominant limb; thus, it is recommended that additional bilateral training be undertaken in order to attenuate this and improve overall kicking performance.

18.
Vet Rec ; 175(15): 370, 2014 Oct 18.
Article in English | MEDLINE | ID: mdl-25053269

ABSTRACT

The medical records of dogs receiving surgery for unilateral patellar ligament rupture between 1999 and 2012 at 12 multidisciplinary referral centres were reviewed. Forty-three cases were identified; 26 were traumatic in origin; almost one-third were iatrogenic, of which over three-quarters occurred as a complication following surgical stabilisation of patellar luxation. Treatment involved primary reapposition of the ligament (36 cases). The repair was protected by circumpatellar and/or transpatellar loop(s) of orthopaedic wire, nylon, polypropylene or polydioxanone suture (34 cases). Wire loops were more likely to require surgical removal compared with loops of other materials (P=0.0014). The stifle joint was immobilised postoperatively by the applications of a transarticular external skeletal fixator (taESF) in 17 cases and by external coaptation (EC) in 8 cases; in 18 cases, no postoperative joint immobilisation was provided. Complications specific to the method of immobilisation occurred in seven of the cases with taESF and six of the cases with EC. Revision surgery to address failure of repair was required in five cases. Outcome was classified as acceptable or good in over three-quarters of the cases (31/40) and poor in less than a quarter (9/40). These data highlight patellar ligament rupture as a complication of surgical stabilisation of patellar luxation.


Subject(s)
Patellar Ligament/injuries , Patellar Ligament/surgery , Plastic Surgery Procedures/veterinary , Animals , Dogs , Female , Ireland , Male , Plastic Surgery Procedures/methods , Records , Retrospective Studies , Rupture/surgery , Rupture/veterinary , Treatment Outcome , United Kingdom , Veterinary Medicine
19.
Vet Comp Orthop Traumatol ; 26(6): 445-52, 2013.
Article in English | MEDLINE | ID: mdl-24008374

ABSTRACT

OBJECTIVE: To compare complication rates and the outcomes of these complications after lateral plate fixation with figure-of-eight tension-band-wire and pin or lag screw fixation for arthrodesis of the calcaneoquartal joint, following non-traumatic disruption of the plantar tarsal ligament in dogs. METHODS: Data were collected retrospectively from five UK referral centres. Diplomate specialists and their residents performed all procedures. Referring veterinarians were contacted for long-term follow-up. RESULTS: Seventy-four procedures were undertaken in 61 dogs. There were 58 arthrodeses in the lateral plate group (Plate), nine in the pin and tension-band-wire group (Pin), and seven in the lag screw and tension-band wire-group (Screw). Compared to Plate (17%), further surgical intervention was required more frequently following Pin (56%, OR = 3.2) or Screw (43%, OR = 2.5) fixation. Clinical failure of arthrodesis occurred less frequently with Plate (5%) compared with Screw (43%, OR = 8.6) and Pin fixation (22%, OR = 4.4). Cases managed with external coaptation postoperatively were more likely to suffer from postoperative complications (OR = 2.2). CLINICAL SIGNIFICANCE: Lateral plating was associated with fewer postoperative complications than pin and tension-band-wire fixation for arthrodesis of the calcaneoquartal joint in dogs with non-traumatic disruption of the plantar tarsal ligament.


Subject(s)
Arthrodesis/veterinary , Bone Plates/veterinary , Bone Screws/veterinary , Bone Wires/veterinary , Dog Diseases/surgery , Animals , Arthrodesis/instrumentation , Arthrodesis/methods , Dogs , Female , Joint Dislocations/etiology , Joint Dislocations/surgery , Joint Dislocations/veterinary , Ligaments/pathology , Male , Postoperative Complications/veterinary , Retrospective Studies , Rupture/complications , Rupture/veterinary , Tarsal Joints/pathology , Tarsal Joints/surgery
20.
Biotechnol Bioeng ; 110(6): 1583-94, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23280255

ABSTRACT

A microalgae biomass growth model was developed for screening novel strains for their potential to exhibit high biomass productivities under nutrient-replete conditions in photobioreactors or outdoor ponds. Growth is modeled by first estimating the light attenuation by biomass according to Beer-Lambert's Law, and then calculating the specific growth rate in discretized culture volume slices that receive declining light intensities due to attenuation. The model uses only two physical and two species-specific biological input parameters, all of which are relatively easy to determine: incident light intensity, culture depth, as well as the biomass light absorption coefficient and the specific growth rate as a function of light intensity. Roux bottle culture experiments were performed with Nannochloropsis salina at constant temperature (23°C) at six different incident light intensities (10, 25, 50, 100, 250, and 850 µmol/m(2) s) to determine both the specific growth rate under non-shading conditions and the biomass light absorption coefficient as a function of light intensity. The model was successful in predicting the biomass growth rate in these Roux bottle batch cultures during the light-limited linear phase at different incident light intensities. Model predictions were moderately sensitive to minor variations in the values of input parameters. The model was also successful in predicting the growth performance of Chlorella sp. cultured in LED-lighted 800 L raceway ponds operated in batch mode at constant temperature (30°C) and constant light intensity (1,650 µmol/m(2) s). Measurements of oxygen concentrations as a function of time demonstrated that following exposure to darkness, it takes at least 5 s for cells to initiate dark respiration. As a result, biomass loss due to dark respiration in the aphotic zone of a culture is unlikely to occur in highly mixed small-scale photobioreactors where cells move rapidly in and out of the light. By contrast, as supported also by the growth model, biomass loss due to dark respiration occurs in the dark zones of the relatively less well-mixed pond cultures. In addition to screening novel microalgae strains for high biomass productivities, the model can also be used for optimizing the pond design and operation. Additional research is needed to validate the biomass growth model for other microalgae species and for the more realistic case of fluctuating temperatures and light intensities observed in outdoor pond cultures.


Subject(s)
Biomass , Microalgae/growth & development , Models, Biological , Photobioreactors , Ponds , Absorption , Biofuels , Chlorella/growth & development , Chlorella/physiology , Light , Microalgae/physiology , Reproducibility of Results , Stramenopiles/growth & development , Stramenopiles/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...