1.
AJR Am J Roentgenol ; 211(6): 1283-1290, 2018 12.
Article in English | MEDLINE | ID: mdl-30354270

ABSTRACT

OBJECTIVE: The purpose of this study was to develop a road map for rapid construction of anthropomorphic phantoms from computational human phantoms for use in diagnostic imaging dosimetry studies. These phantoms are ideal for performing pregnant-patient dosimetry because the phantoms imitate the size and attenuation properties of an average-sized pregnant woman for multiple gestational periods. MATERIALS AND METHODS: The method was derived from methods and materials previously described but adapted for 3D printing technology. A 3D printer was used to transform computational models into a physical duplicate with small losses in spatial accuracy and to generate tissue-equivalent materials characterized for diagnostic energy x-rays. A series of pregnant abdomens were selected as prototypes because of their large size and complex modeling. The process involved the following steps: segmentation of anatomy used for modeling; transformation of the computational model into a printing file format; preparation, characterization, and introduction of phantom materials; and model removal and phantom assembly. RESULTS: The density of the homogenized soft tissue-equivalent substitute was optimized by combining 9.0% by weight of urethane filler powder and 91.0% urethane polymer, which resulted in a mean density of 1.041 g/cm3 measured over 20 samples. Density varied among all of the samples by 0.0026 g/cm3. The total variation in density was 0.00261 g/cm3. The half-value layer of the bone material was measured to be 1.7 mm of bone material at 120 kVp and when simulated by use of the density of the bone tissue-equivalent substitute (1.60 g/cm3) was determined to be 1.61 mm of bone tissue. For dosimetry purposes the phantom provided excellent results for evaluating a site's protocol based on scan range. CONCLUSION: The 3D printing technology is applicable to the fabrication of phantoms used for performing dosimetry. The tissue-equivalent materials used to substitute for the soft tissue were developed to be highly adaptable for optimization based on the dosimetry application. Use of this method resulted in more automated phantom construction with decreased construction time and increased out-of-slice spatial resolution of the phantoms.


Subject(s)
Anthropometry , Computer Simulation , Pelvis/diagnostic imaging , Phantoms, Imaging , Printing, Three-Dimensional , Radiometry , Female , Humans , Pregnancy
2.
Med Phys ; 42(3): 1268-79, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25735282

ABSTRACT

PURPOSE: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. METHODS: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 µm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 µm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm(3) Radcal(®) thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm(3) calibrated ionization chamber to measure the reference air kerma. RESULTS: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. CONCLUSIONS: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.


Subject(s)
Optical Fibers , Scintillation Counting/instrumentation , Tomography, X-Ray Computed/instrumentation , Electrons , Monte Carlo Method , Phantoms, Imaging , Photons
3.
Med Phys ; 40(1): 013901, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23298124

ABSTRACT

PURPOSE: To validate the accuracy of a Monte Carlo source model of the Siemens SOMATOM Sensation 16 CT scanner using organ doses measured in physical anthropomorphic phantoms. METHODS: The x-ray output of the Siemens SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code, MCNPX version 2.6. The resulting source model was able to perform various simulated axial and helical computed tomographic (CT) scans of varying scan parameters, including beam energy, filtration, pitch, and beam collimation. Two custom-built anthropomorphic phantoms were used to take dose measurements on the CT scanner: an adult male and a 9-month-old. The adult male is a physical replica of the University of Florida reference adult male hybrid computational phantom, while the 9-month-old is a replica of the University of Florida Series B 9-month-old voxel computational phantom. Each phantom underwent a series of axial and helical CT scans, during which organ doses were measured using fiber-optic coupled plastic scintillator dosimeters developed at the University of Florida. The physical setup was reproduced and simulated in MCNPX using the CT source model and the computational phantoms upon which the anthropomorphic phantoms were constructed. Average organ doses were then calculated based upon these MCNPX results. RESULTS: For all CT scans, good agreement was seen between measured and simulated organ doses. For the adult male, the percent differences were within 16% for axial scans, and within 18% for helical scans. For the 9-month-old, the percent differences were all within 15% for both the axial and helical scans. These results are comparable to previously published validation studies using GE scanners and commercially available anthropomorphic phantoms. CONCLUSIONS: Overall results of this study show that the Monte Carlo source model can be used to accurately and reliably calculate organ doses for patients undergoing a variety of axial or helical CT examinations on the Siemens SOMATOM Sensation 16 scanner.


Subject(s)
Monte Carlo Method , Phantoms, Imaging , Radiation Dosage , Tomography, X-Ray Computed/instrumentation , Adult , Humans , Infant , Male