Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Cardiol Heart Vasc ; 47: 101222, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37252196

ABSTRACT

Background: The automated NavX Ensite Precision latency-map (LM) algorithm aims to identify atrial tachycardia (AT) mechanisms. However, data on a direct comparison of this algorithm with conventional mapping are scarce. Methods: Patients scheduled for AT ablation were randomized to mapping with the LM- algorithm (LM group) or to conventional mapping (conventional only group: ConvO), using entrainment and local activation mapping techniques. Several outcomes were exploratively analyzed. Primary endpoint was intraprocedural AT Termination. If AT termination with only automated 3D-Mapping failed, additional conventional methods were applied (conversion). Results: A total of 63 patients (mean 67 years, 34 % female) were enrolled. In the LM group (n = 31), the correct AT mechanism was identified in 14 patients (45 %) using the algorithm alone compared to 30 patients (94 %) with conventional methods. Time to termination of the first AT was not different between groups (LM group 34 ± 20 vs. ConvO 43.1 ± 28.3 min; p = 0.2). However, when AT termination did not occur with LM algorithm, time to termination prolonged significantly (65 ± 35 min; p = 0.01). After applying conventional methods (conversion), procedural termination rates did not differ between LM group (90 %) vs. ConvO (94 %) (p = 0.3). During a follow-up time of 20 ± 9 months, no differences were observed in clinical outcomes. Conclusion: In this small prospective, randomized study, the use of the LM algorithm alone may lead to AT termination, but less accurate than conventional methods.

2.
J Interv Card Electrophysiol ; 64(2): 417-426, 2022 Aug.
Article in English | MEDLINE | ID: mdl-34373981

ABSTRACT

BACKGROUND: Complex ablation for persistent atrial fibrillation (AF) aims to modify the arrhythmogenic substrates to become incapable to perpetuate the arrhythmia. Ablation-associated determinants of atrial tachycardia (AT) rather than AF recurrences are unknown. The aim of the study was to evaluate the association between the type of arrhythmia recurrence and electrophysiological findings during redo procedures. METHODS: A total number of 384 consecutive patients with persistent AF underwent complex ablation consisting of PV isolation (PVI), biatrial electrogram-guided ablation, and linear ablation with the desired procedural endpoint of AF termination. Electrophysiological findings during redo procedures and its relation to AR type are the subject of this study. RESULTS: Overall, 177 (46%) patients underwent a second procedure. Patients with AT recurrences had significantly more often persistent PVI (47 vs. 25%; P = 0.002). Moreover, a higher number of recovered PVs were associated with AF recurrence (3 PVs recovered, AF = 16.1% vs. AT = 5.2%; P = 0.02; 4 PVs recovered, AF = 18.5% vs. AT = 6.3%; P = 0.01), regardless of the extent of substrate ablation during the first procedure. CONCLUSIONS: Durable PV isolation but not the extent of atrial substrate ablation determines the type of arrhythmia recurrence. Thus, the PVs may represent dominant perpetuators (and not only triggers) of persistent AF even in the presence of a significantly modified atrial substrate.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Tachycardia, Supraventricular , Atrial Fibrillation/surgery , Catheter Ablation/methods , Humans , Pulmonary Veins/surgery , Recurrence , Tachycardia, Supraventricular/surgery , Treatment Outcome
3.
J Cardiovasc Electrophysiol ; 29(4): 537-547, 2018 04.
Article in English | MEDLINE | ID: mdl-29377448

ABSTRACT

AIMS: To evaluate the incidence of newly diagnosed intracardiac thrombi (ICT) in respect to the mode of OAC in patients undergoing cardioversion (CV). METHODS AND RESULTS: We prospectively assessed transesophageal echocardiography (TEE) and OAC therapy prior to CV in AF patients with ≥48-hour duration scheduled for CV. A total of 60 first-time ICT (4.7%) were diagnosed in 1,286 TEE, with highest rate in patients without OAC (9.6% vs. OAC 4.1%, P  =  0.009) and an apparently lower rate in nonvitamin K antagonist anticoagulants (NOAC) therapy compared to vitamin K antagonist (VKA) (2.5% vs. 5.3%, P  =  0.02). VKA therapy control 4 weeks prior to CV was overall average (time in therapeutic range 60%) and patients showed more frequently clinical characteristics and TEE parameters associated with risk for ICT. Even among patients with effective OAC therapy (uninterrupted NOAC and VKA therapy with international normalized ratio (INR) ≥2.0 for 3 weeks), ICT occurred in 2.7%, but with no difference between both groups (P  =  0.22). There was no difference between different types of NOAC. Independent predictors for ICT were history of embolism, hypertension, BMI, absence of OAC, renal function, reduced atrial appendage flow, and presence of spontaneous echo contrast. CONCLUSION: NOAC therapy seems favorable in the overall prevention of ICT, although this is likely to be caused by suboptimal VKA therapy control and differences in the overall health status between VKA and NOAC patients. ICT occurred even with effective OAC therapy suggesting individual TEE-guided cardioversion in patients at risk.


Subject(s)
Anticoagulants/administration & dosage , Atrial Fibrillation/therapy , Thrombosis/prevention & control , Administration, Oral , Aged , Anticoagulants/adverse effects , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Echocardiography, Doppler, Pulsed , Echocardiography, Transesophageal , Electric Countershock , Electrocardiography , Female , Health Status , Humans , Incidence , International Normalized Ratio , Male , Middle Aged , Prospective Studies , Risk Factors , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Time Factors , Treatment Outcome