Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Publication year range
1.
Water Res ; 178: 115816, 2020 Jul 01.
Article in English | MEDLINE | ID: mdl-32353612

ABSTRACT

Universalising actions aimed at water supply in rural communities and indigenous populations must focus on simple and low-cost technologies adapted to the local context. In this setting, this research studied the dynamic gravel filter (DGF) as a pre-treatment to household slow-sand filters (HSSFs), which is the first description of a household multistage filtration scale to treat drinking water. DGFs (with and without a non-woven blanket on top of the gravel layer) followed by HSSFs were tested. DGFs operated with a filtration rate of 3.21 m3 m-2.d-1 and HSSFs with 1.52 m3 m-2.d-1. Influent water contained kaolinite, humic acid and suspension of coliforms and protozoa. Physical-chemical parameters were evaluated, as well as Escherichia coli, Giardia spp. cysts and Cryptosporidium spp. oocyst reductions. Removal was low (up to 6.6%) concerning true colour, total organic carbon and absorbance (λ = 254 nm). Nevertheless, HMSFs showed turbidity decrease above 60%, E. coli reduction up to 1.78 log, Giardia cysts and Cryptosporidium oocysts reductions up to 3.15 log and 2.24 log, respectively. The non-woven blanket was shown as an important physical barrier to remove solids, E. coli and protozoa.


Subject(s)
Cryptosporidiosis , Cryptosporidium , Drinking Water , Water Purification , Animals , Escherichia coli , Filtration , Water Supply
2.
Angiology ; 48(11): 1001-5, 1997 Nov.
Article in English | MEDLINE | ID: mdl-9373054

ABSTRACT

Idiopathic or congenital coronary artery ectasias and aneurysms are uncommon forms of coronary artery disease. The prognosis and optimal management of such patients remains unknown. The authors describe the case of an otherwise healthy 30-year-old man with concomitant severe right coronary artery ectasia and left main coronary artery aneurysm who sustained a mild anterior myocardial infarction. There was no obstructive coronary artery disease, and no cause for the lesions could be identified. Chronic anticoagulation and antiplatelet therapy were initiated with resolution of symptoms.


Subject(s)
Coronary Aneurysm/complications , Coronary Vessel Anomalies/complications , Myocardial Infarction/complications , Adult , Coronary Aneurysm/pathology , Coronary Vessel Anomalies/pathology , Humans , Male , Myocardial Infarction/pathology
3.
Cathet Cardiovasc Diagn ; 42(2): 173-9, 1997 Oct.
Article in English | MEDLINE | ID: mdl-9328702

ABSTRACT

Emergent percutaneous transluminal coronary angioplasty (PTCA) is an effective treatment for acute myocardial infarction. However, occasionally results of angioplasty are suboptimal due to coronary dissection or elastic recoil, leading to a high chance of recurrent ischemia. Coronary stents are occasionally employed in such settings, but a high incidence of stent thrombosis was noted by early investigators when stents were placed into areas of active thrombus formation. Since coronary thrombosis and stent thrombosis are both initiated by platelets, the potent antiplatelet agent abciximab might be useful in preventing stent thrombosis. Little information is available concerning early outcome or 6-month clinical event rate when coronary artery stents are placed for suboptimal angioplasty results for acute myocardial infarction in patients given abciximab. We deployed 75 stents as part of angioplasty for acute myocardial infarction in 40 patients given abciximab. All patients had suboptimal angioplasty results leading to stent deployment. Each obtained normal flow angiographically and no stent thrombosis or acute closure was observed. Early mortality occurred in 1 patient. All patients were followed at least 6 months, and no patient died after hospital discharge. Three patients experienced recurrent ischemic events within the first 6 months. Two of these events were due to infarct vessel restenosis. We conclude the combined use of coronary artery stents and abciximab for suboptimal PTCA results during acute myocardial infarction is associated with a low incidence of culprit vessel recurrent ischemic events within 6 months of intervention.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Antibodies, Monoclonal/administration & dosage , Immunoglobulin Fab Fragments/administration & dosage , Myocardial Infarction/therapy , Platelet Aggregation Inhibitors/administration & dosage , Stents , Abciximab , Adult , Aged , Aged, 80 and over , Combined Modality Therapy , Coronary Angiography , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/mortality , Coronary Thrombosis/prevention & control , Female , Follow-Up Studies , Humans , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/mortality , Recurrence , Survival Analysis , Treatment Outcome
4.
Cathet Cardiovasc Diagn ; 41(4): 440-1, 1997 Aug.
Article in English | MEDLINE | ID: mdl-9258494

ABSTRACT

Current prepping of the Johnson & Johnson stent deployment balloon can be suboptimal. This simple technique allows for an improved preparation of the stent delivery balloon prior to deployment, resulting in less air in the balloon during inflation.


Subject(s)
Catheterization/methods , Coronary Vessels , Stents , Catheterization/instrumentation , Equipment Design , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...