Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Nucl Med Commun ; 37(11): 1212-7, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27501436

ABSTRACT

The interest in quantitative single photon emission computer tomography (SPECT) shows potential in a number of clinical applications and now several vendors are providing software and hardware solutions to allow 'SUV-SPECT' to mirror metrics used in PET imaging. This brief technical report assesses the accuracy of activity concentration measurements using a new algorithm 'xSPECT' from Siemens Healthcare. SPECT/CT data were acquired from a uniform cylinder with 5, 10, 15 and 20 s/projection and NEMA image quality phantom with 25 s/projection. The NEMA phantom had hot spheres filled with an 8 : 1 activity concentration relative to the background compartment. Reconstructions were performed using parameters defined by manufacturer presets available with the algorithm. The accuracy of activity concentration measurements was assessed. A dose calibrator-camera cross-calibration factor (CCF) was derived from the uniform phantom data. In uniform phantom images, a positive bias was observed, ranging from ∼6% in the lower count images to ∼4% in the higher-count images. On the basis of the higher-count data, a CCF of 0.96 was derived. As expected, considerable negative bias was measured in the NEMA spheres using region mean values whereas positive bias was measured in the four largest NEMA spheres. Nonmonotonically increasing recovery curves for the hot spheres suggested the presence of Gibbs edge enhancement from resolution modelling. Sufficiently accurate activity concentration measurements can easily be measured on images reconstructed with the xSPECT algorithm without a CCF. However, the use of a CCF is likely to improve accuracy further. A manual conversion of voxel values into SUV should be possible, provided that the patient weight, injected activity and time between injection and imaging are all known accurately.


Subject(s)
Algorithms , Phantoms, Imaging/statistics & numerical data , Tomography, Emission-Computed, Single-Photon/statistics & numerical data , Bias , Gamma Cameras/statistics & numerical data , Humans , Reproducibility of Results , Single Photon Emission Computed Tomography Computed Tomography/instrumentation , Single Photon Emission Computed Tomography Computed Tomography/statistics & numerical data , Tomography, Emission-Computed, Single-Photon/instrumentation
2.
Nucl Med Commun ; 28(6): 451-6, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17460535

ABSTRACT

OBJECTIVE: To assess the utility of the appearances of occipital lobe perfusion on HMPAO SPECT in the diagnosis of dementia with Lewy bodies (DLB) using the 123I-FP-CIT findings as the diagnostic 'gold standard'. METHODS: Eighty-four consecutive patients underwent both HMPAO SPECT and 123I-FP-CIT as part of their routine investigations for suspected DLB. RESULTS: Thirty-nine of the 84 FP-CIT scans were abnormal indicating a prevalence of 44% of patients with DLB in this series. In those patients classified as DLB, 28% of HMPAO SPECT scans demonstrated occipital hypoperfusion. In those patients with a dementia other than DLB 31% of patients demonstrated occipital hypoperfusion (P=0.8). CONCLUSION: Occipital lobe hypoperfusion as demonstrated by HMPAO SPECT in patients with suspected Lewy body dementia does not appear to be able to either rule in, or rule out, the diagnosis of DLB.


Subject(s)
Lewy Body Disease/diagnostic imaging , Occipital Lobe/diagnostic imaging , Tomography, Emission-Computed, Single-Photon/methods , Diagnosis, Differential , Female , Humans , Male , Occipital Lobe/blood supply , Predictive Value of Tests , Retrospective Studies , Sensitivity and Specificity
3.
Nucl Med Commun ; 26(12): 1099-106, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16264357

ABSTRACT

AIM: To assess the role of 99mTc-hexamethylpropyleneamine oxime single-photon emission computed tomography (99mTc-HMPAO SPECT) imaging of the precuneus and medial temporal lobe in the individual patient with mild Alzheimer's disease and dementia with Lewy bodies (DLB) using statistical parametric mapping and visual image interpretation. METHODS: Thirty-four patients with mild late-onset Alzheimer's disease, 20 patients with early-onset Alzheimer's disease, 15 patients with DLB and 31 healthy controls were studied. All patients fulfilled appropriate clinical criteria; the DLB patients also had evidence of dopaminergic presynaptic terminal loss on 123I-N-omega-fluoropropyl-2beta-carbomethoxy-3beta-(4-iodophenyl)-tropane imaging. 99mTc-HMPAO SPECT brain scans were acquired on a multidetector gamma camera and images were assessed separately by visual interpretation and with SPM99. RESULTS: Statistical parametric maps were significantly more accurate than visual image interpretation in all disease categories. In patients with mild late-onset Alzheimer's disease, statistical parametric mapping demonstrated significant hypoperfusion to the precuneus in 59% and to the medial temporal lobe in 53%. Seventy-six per cent of these patients had a defect in either location. No controls had precuneal or medial temporal lobe hypoperfusion (specificity, 100%). Statistical parametric mapping also demonstrated 73% of patients with DLB to have precuneal abnormalities, but only 6% had medial temporal lobe involvement. CONCLUSION: These findings illustrate the capability of statistical parametric mapping to demonstrate reliable abnormalities in the majority, but not all, patients with either mild Alzheimer's disease or DLB. Precuneal hypoperfusion is not specific to Alzheimer's disease and is equally likely to be found in DLB. In this study, medial temporal hypoperfusion was significantly more common in Alzheimer's disease than in DLB. Statistical parametric maps appear to be considerably more reliable than simple visual interpretation of 99mTc-HMPAO images for these regions.


Subject(s)
Alzheimer Disease/pathology , Brain Mapping/methods , Lewy Body Disease/pathology , Technetium Tc 99m Exametazime/pharmacology , Temporal Lobe/anatomy & histology , Tomography, Emission-Computed, Single-Photon/methods , Adult , Aged , Aged, 80 and over , Brain/pathology , Case-Control Studies , Cerebral Cortex/anatomy & histology , Computational Biology , Data Interpretation, Statistical , Female , Humans , Iodine Radioisotopes , Male , Middle Aged , Models, Statistical , Perfusion , Software , Temporal Lobe/pathology , Tropanes
SELECTION OF CITATIONS
SEARCH DETAIL
...