Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Micromachines (Basel) ; 14(12)2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38138396

ABSTRACT

We present in this work new methodologies to produce, refine, and interconnect room-temperature liquid-metal-core thermoplastic elastomer wires that have extreme extendibility (>500%), low production time and cost at scale, and may be integrated into commonly used electrical prototyping connectors like a Japan Solderless Terminal (JST) or Dupont connectors. Rather than focus on the development of a specific device, the aim of this work is to demonstrate strategies and processes necessary to achieve scalable production of liquid-metal-enabled electronics and address several key challenges that have been present in liquid metal systems, including leak-free operation, minimal gallium corrosion of other electrode materials, low liquid metal consumption, and high production rates. The ultimate goal is to create liquid-metal-enabled rapid prototyping technologies, similar to what can be achieved with Arduino projects, where modification and switching of components can be performed in seconds, which enables faster iterations of designs. Our process is focused primarily on fibre-based liquid metal wires contained within thermoplastic elastomers. These fibre form factors can easily be integrated with wearable sensors and actuators as they can be sewn or woven into fabrics, or cast within soft robotic components.

2.
Clin Biomech (Bristol, Avon) ; 107: 106012, 2023 07.
Article in English | MEDLINE | ID: mdl-37295339

ABSTRACT

BACKGROUND: When developing a surrogate model of the human skull, there is a multitude of morphometric and geometric properties to consider when constructing the model. To simplify this approach, it is important to identify only the properties that have a significant influence on the mechanical response of the skull. The objective of this study was to identify which morphometric and geometric properties of the calvarium were significant predictors of mechanical response. METHODS: Calvarium specimens (N = 24) were micro-computed tomography scanned to determine morphometric and geometric properties. The specimens were assumed to be Euler-Bernoulli beams and were subject to 4-point quasi-static bending to determine mechanical response. Univariate linear regressions were performed whereby the morphometric and geometric properties were independent or predictor variables and the mechanical responses were dependent or outcome variables. FINDINGS: Nine significant linear regression models were established (p < 0.05). In the diploë, trabecular bone pattern factor was a significant predictor of force and bending moment at fracture. The inner cortical table had more significant predictors (thickness, tissue mineral density, and porosity) of mechanical response compared to the outer cortical table and diploë. INTERPRETATION: Morphometric and geometric properties had a key influence on the calvarium's biomechanics. Trabecular bone pattern factor and the morphometry and geometry of the cortical tables must be considered when evaluating the mechanical response of the calvarium. These properties can aid the design of surrogate models of the skull that seek to mimic its mechanical response for head impact simulation.


Subject(s)
Cancellous Bone , Skull , Humans , X-Ray Microtomography , Skull/diagnostic imaging , Head , Biomechanical Phenomena , Bone Density
3.
Sci Rep ; 13(1): 3751, 2023 Mar 07.
Article in English | MEDLINE | ID: mdl-36882492

ABSTRACT

Photoacoustic remote sensing has been recently developed as an all-optical imaging modality capable of imaging a variety of endogenous contrast agents label-free. Initially predicted laser pulse-induced refractive index perturbation-based interrogation beam reflectivity modulations have been found to be orders of magnitude smaller than those typically observed experimentally. In this report we utilize a 10 million frames-per-second camera to further investigate these predicted reflectivity modulations, while also exploring other potential mechanisms of laser pulse-induced reflectivity modulations. Laser-induced motion is demonstrated both laterally for gold wires suspended and submerged in air and water, respectively, and carbon fibers submerged in water, and axial motion is observed in gold wires submerged in a depth gradient of intralipid solution. This laser-induced sample motion is anticipated to cause reflectivity modulations local to the interrogation beam profile in microscopy set-ups. Non-motion-based maximum intensity modulations of 3% are also observed in gold wires submerged in water, indicating the presence of the originally predicted reflectivity modulations. Overall, these observations are important as they provide a widefield view of laser-pulse interactions unavailable in previous point scanning-based photoacoustic remote sensing microscopy configurations, where observed mechanisms occur on time-scales orders of magnitude faster than equivalent field of view point scanning capabilities.

4.
J Mech Behav Biomed Mater ; 123: 104779, 2021 11.
Article in English | MEDLINE | ID: mdl-34425349

ABSTRACT

The coefficient of thermal expansion (CTE) in biological tissues is an integral parameter behind the application of electromagnetic energy to biomedical technologies; however, its behavior is far from being fully characterized. In this study, we apply digital image correlation (DIC) to non-invasively measure the microscale thermal expansions of recently excised embryonic E18 rodent brain tissue slices. Although the CTE has been measured previously in soft tissues, the literature surrounding the expansion of brain tissue remains sparse. Previous work in measuring the thermal expansion behavior of soft tissue often simplifies the results into a single measurement of a linear CTE parameter and fails to convey the temperature-dependent nonlinearity that exists. In this work, we demonstrate that: (1) the coefficient of brain tissue is more similar to fat than blood, and (2) there exists a significant nonlinear increase in CTE at physiologically-relevant temperatures. This suggests some limitations with the interpretation of previously reported values of the CTE, which are often measured at room temperature.


Subject(s)
Brain , Temperature
5.
Micromachines (Basel) ; 12(7)2021 Jun 30.
Article in English | MEDLINE | ID: mdl-34208985

ABSTRACT

Protective textiles used for military applications must fulfill a variety of functional requirements, including durability, resistance to environmental conditions and ballistic threats, all while being comfortable and lightweight. In addition, these textiles must provide camouflage and concealment under various environmental conditions and, thus, a range of wavelengths on the electromagnetic spectrum. Similar requirements may exist for other applications, for instance hunting. With improvements in infrared sensing technology, the focus of protective textile research and development has shifted solely from providing visible camouflage to providing camouflage in the infrared (IR) region. Smart textiles, which can monitor and react to the textile wearer or environmental stimuli, have been applied to protective textiles to improve camouflage in the IR spectral range. This study presents a review of current smart textile technologies for visible and IR signature control of protective textiles, including coloration techniques, chromic materials, conductive polymers, and phase change materials. We propose novel fabrication technology combinations using various microfabrication techniques (e.g., three-dimensional (3D) printing; microfluidics; machine learning) to improve the visible and IR signature management of protective textiles and discuss possible challenges in terms of compatibility with the different textile performance requirements.

6.
Bone ; 148: 115931, 2021 07.
Article in English | MEDLINE | ID: mdl-33766803

ABSTRACT

There is currently a gap in the literature that quantitatively describes the complex bone microarchitecture within the diploë (trabecular bone) and cortical layers of the human calvarium. The purpose of this study was to determine the morphometric properties of the diploë and cortical tables of the human calvarium in which key interacting factors of sex, location on the calvarium, and layers of the sandwich structure were considered. Micro-computed tomography (micro-CT) was utilized to capture images at 18 µm resolution of male (n = 26) and female (n = 24) embalmed calvarium specimens in the frontal and parietal regions (N = 50). All images were post-processed and analyzed using vendor bundled CT-Analyzer software to determine the morphometric properties of the diploë and cortical layers. A two-way mixed (repeated measures) analysis of variance (ANOVA) was used to determine diploë morphometric properties accounting for factors of sex and location. A three-way mixed ANOVA was performed to determine cortical morphometric properties accounting for factors of cortical layer (inner and outer table), sex, and location. The study revealed no two-way interaction effects between sex and location on the diploë morphometry except for fractal dimension. Trabecular thickness and separation in the diploë were significantly greater in the male specimens; however, females showed a greater number of trabeculae and fractal dimension on average. Parietal specimens revealed a greater porosity, trabecular separation, and deviation from an ideal plate structure, but a lesser number of trabeculae and connectivity compared to the frontal location. Additionally, the study observed a lower density and greater porosity in the inner cortical layer than the outer which may be due to clear distinctions between each layer's physiological environment. The study provides valuable insight into the quantitative morphometry of the calvarium in which finite element modelers of the skull can refer to when designing detailed heterogenous or subject-specific skull models to effectively predict injury. Furthermore, this study contributes towards the recent developments on physical surrogate models of the skull which require approximate measures of calvarium bone architecture in order to effectively fabricate a model and then accurately simulate a traumatic head impact event.


Subject(s)
Models, Theoretical , Skull , Bone Density , Female , Humans , Male , Porosity , Skull/diagnostic imaging , X-Ray Microtomography
7.
J Fish Biol ; 96(2): 456-468, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31814124

ABSTRACT

We assessed the prevalence of life history variation across four of the five native amphidromous Hawai'ian gobioids to determine whether some or all exhibit evidence of partial migration. Analysis of otolith Sr.: Ca concentrations affirmed that all are amphidromous and revealed evidence of partial migration in three of the four species. We found that 25% of Lentipes concolor (n = 8), 40% of Eleotris sandwicensis (n = 20) and 29% of Stenogobius hawaiiensis (n = 24) did not exhibit a migratory life-history. In contrast, all individuals of Sicyopterus stimpsoni (n = 55) included in the study went to sea as larvae. Lentipes concolor exhibited the shortest mean larval duration (LD) at 87 days, successively followed by E. sandwicensis (mean LD = 102 days), S. hawaiiensis (mean LD = 114 days) and S. stimpsoni (mean LD = 120 days). These findings offer a fresh perspective on migratory life histories that can help improve efforts to conserve and protect all of these and other at-risk amphidromous species that are subject to escalating anthropogenic pressures in both freshwater and marine environments.


Subject(s)
Animal Migration/physiology , Fishes/physiology , Otolithic Membrane/physiology , Animals , Fresh Water , Hawaii , Larva , Seawater
8.
PLoS One ; 10(6): e0131617, 2015.
Article in English | MEDLINE | ID: mdl-26111004

ABSTRACT

Although a number of cytoskeletal derangements have been described in the setting of traumatic axonal injury (TAI), little is known of early structural changes that may serve to initiate a cascade of further axonal degeneration. Recent work by the authors has examined conformational changes in cytoskeletal constituents of neuronal axons undergoing traumatic axonal injury (TAI) following focal compression through confocal imaging data taken in vitro and in situ. The present study uses electron microscopy to understand and quantify in vitro alterations in the ultrastructural composition of microtubules and neurofilaments within neuronal axons of rats following focal compression. Standard transmission electron microscopy processing methods are used to identify microtubules, while neurofilament identification is performed using antibody labeling through gold nanoparticles. The number, density, and spacing of microtubules and neurofilaments are quantified for specimens in sham Control and Crushed groups with fixation at <1 min following load. Our results indicate that the axon caliber dependency known to exist for microtubule and neurofilament metrics extends to axons undergoing TAI, with the exception of neurofilament spacing, which appears to remain constant across all Crushed axon diameters. Confidence interval comparisons between Control and Crushed cytoskeletal measures suggests early changes in the neurofilament spatial distributions within axons undergoing TAI may precede microtubule changes in response to applied loads. This may serve as a trigger for further secondary damage to the axon, representing a key insight into the temporal aspects of cytoskeletal degeneration at the component level, and suggests the rapid removal of neurofilament sidearms as one possible mechanism.


Subject(s)
Diffuse Axonal Injury/pathology , Hippocampus/cytology , Intermediate Filaments/pathology , Microtubules/pathology , Spinal Cord Injuries/pathology , Animals , Axons/physiology , Cells, Cultured , Cytoskeleton/physiology , Intermediate Filaments/ultrastructure , Microscopy, Electron , Microtubules/ultrastructure , Nerve Degeneration/pathology , Primary Cell Culture , Rats , Rats, Sprague-Dawley , Stress, Physiological
SELECTION OF CITATIONS
SEARCH DETAIL
...