J Clin Anesth ; 15(5): 334-8, 2003 Aug.
Article in English | MEDLINE | ID: mdl-14507557

ABSTRACT

STUDY OBJECTIVE: To determine whether tracheoscopy is an accurate and quick method for verifying correct placement of the tracheal tube after intubation. DESIGN: Prospective, randomized study. SETTING: Operating rooms of a teaching hospital. PATIENTS: 26 patients scheduled for surgery and general anesthesia. INTERVENTIONS: 8.0-mm tracheal tubes were inserted into both the trachea and the esophagus. Tracheoscopy was performed consecutively through both tracheal tubes by a variety of clinicians. MEASUREMENTS: The times taken to correctly identify the trachea and the esophagus were recorded. MAIN RESULTS: Correct identification of either the esophagus or the trachea occurred with a 100% sensitivity and a 96% specificity. The mean time to recognize either the trachea or the esophagus was 22.0 seconds. CONCLUSIONS: Tracheoscopy is a reliable method for quickly verifying proper endotracheal placement of a tracheal tube.


Subject(s)
Bronchoscopes , Bronchoscopy/methods , Intubation, Intratracheal , Trachea/anatomy & histology , Anesthesia, General , Double-Blind Method , Esophagus/physiology , Humans