Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Rev Esp Cir Ortop Traumatol ; 68(3): T181-T189, 2024.
Article in English, Spanish | MEDLINE | ID: mdl-38232935

ABSTRACT

INTRODUCTION: The treatment of rhizarthrosis using trapeziometacarpal prostheses (TMP) is increasing. Complications may lead to loss of the implant and result in salvage surgery. Our aim was to assess major complications with the use of some TMP models and their rescue. MATERIAL AND METHOD: Retrospective study on TMP implanted between 2006 and 2021. Models studied: Arpe®, Elektra®, Ivory®, Maïa®, Isis® and Touch®. Demographic data were assessed, implant placement by radiographic study, technical data, complications, salvage surgeries and final survival. RESULTS: Review of 224 TMP, 45 Arpe® (95.5% survival, rate follow-up [R] 6-16 years), 5 Elektra® (80% survival, R 13-14), 14 Ivory® (92.8% survival, R 9-11), 7 Maïa® (100% survival, R 8-9), 115 Isis® (99.1% survival, R 1-8), 38 Touch® (100% survival, R 1-4). The medial angle of the dome with the proximal articular surface of the trapezium in the lateral plane, was: Arpe®: 8.85°, Elektra®: not assessable, Ivory®: 6.6°, Maïa®: 14.4°, Isis®: 3.8°, and Touch®: 5.95°. The Isis® was placed 100% with scopic guidance presenting a significantly lower angle respect to the medial angle of the dome with the proximal articular surface of the trapezium. As main complications, we observed 3.5% of dislocations and 4% of mobilisations, with the Elektra® being responsible for 47% of these. Nineteen salvage surgeries were performed, with 3% of the implants being lost. CONCLUSIONS: Dislocation and mobilisation are the most observed complications, the Elektra® responsible for almost half of them. Correct placement and implant design appear to be crucial to avoid them in the short and long term.

2.
Article in English, Spanish | MEDLINE | ID: mdl-37918688

ABSTRACT

INTRODUCTION: The treatment of rhizarthrosis using trapeziometacarpal prostheses (TMP) is increasing. Complications may lead to loss of the implant and result in salvage surgery. Our aim was to assess major complications with the use of some TMP models and their rescue. MATERIAL AND METHOD: Retrospective study on TMP implanted between 2006 and 2021. Models studied: Arpe®, Elektra®, Ivory®, Maïa®, Isis® and Touch®. Demographic data were assessed, implant placement by radiographic study, technical data, complications, salvage surgeries and final survival. RESULTS: Review of 224 TMP, 45 Arpe® (95.5% survival, rate follow-up [R] 6-16 years), 5 Elektra® (80% survival, R 13-14), 14 Ivory® (92.8% survival, R 9-11), 7 Maïa® (100% survival, R 8-9), 115 Isis® (99.1% survival, R 1-8), 38 Touch® (100% survival, R 1-4). The medial angle of the dome with the proximal articular surface of the trapezium in the lateral plane, was: Arpe®: 8.85°, Elektra®: not assessable, Ivory®: 6.6°, Maïa®: 14.4°, Isis®: 3.8°, and Touch®: 5.95°. The Isis® was placed 100% with scopic guidance presenting a significantly lower angle respect to the medial angle of the dome with the proximal articular surface of the trapezium. As main complications, we observed 3.5% of dislocations and 4% of mobilisations, with the Elektra® being responsible for 47% of these. Nineteen salvage surgeries were performed, with 3% of the implants being lost. CONCLUSIONS: Dislocation and mobilisation are the most observed complications, the Elektra® responsible for almost half of them. Correct placement and implant design appear to be crucial to avoid them in the short and long term.

SELECTION OF CITATIONS
SEARCH DETAIL
...