Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Sens Actuators B Chem ; 173: 817-823, 2012 Oct 01.
Article in English | MEDLINE | ID: mdl-23175599

ABSTRACT

We report a novel method for wafer level, high throughput optical chemical sensor patterning, with precise control of the sensor volume and capability of producing arbitrary microscale patterns. Monomeric oxygen (O(2)) and pH optical probes were polymerized with 2-hydroxyethyl methacrylate (HEMA) and acrylamide (AM) to form spin-coatable and further crosslinkable polymers. A micro-patterning method based on micro-fabrication techniques (photolithography, wet chemical process and reactive ion etch) was developed to miniaturize the sensor film onto glass substrates in arbitrary sizes and shapes. The sensitivity of fabricated micro-patterns was characterized under various oxygen concentrations and pH values. The process for spatially integration of two sensors (Oxygen and pH) on the same substrate surface was also developed, and preliminary fabrication and characterization results were presented. To the best of our knowledge, it is the first time that poly (2-hydroxylethyl methacrylate)-co-poly (acrylamide) (PHEMA-co-PAM)-based sensors had been patterned and integrated at the wafer level with micron scale precision control using microfabrication techniques. The developed methods can provide a feasible way to miniaturize and integrate the optical chemical sensor system and can be applied to any lab-on-a-chip system, especially the biological micro-systems requiring optical sensing of single or multiple analytes.

2.
J Biomed Opt ; 17(3): 037008, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22502580

ABSTRACT

Intercellular heterogeneity is a key factor in a variety of core cellular processes including proliferation, stimulus response, carcinogenesis, and drug resistance. However, cell-to-cell variability studies at the single-cell level have been hampered by the lack of enabling experimental techniques. We present a measurement platform that features the capability to quantify oxygen consumption rates of individual, non-interacting and interacting cells under normoxic and hypoxic conditions. It is based on real-time concentration measurements of metabolites of interest by means of extracellular optical sensors in cell-isolating microwells of subnanoliter volume. We present the results of a series of measurements of oxygen consumption rates (OCRs) of individual non-interacting and interacting human epithelial cells. We measured the effects of cell-to-cell interactions by using the system's capability to isolate two and three cells in a single well. The major advantages of the approach are: 1. ratiometric, intensity-based characterization of the metabolic phenotype at the single-cell level, 2. minimal invasiveness due to the distant positioning of sensors, and 3. ability to study the effects of cell-cell interactions on cellular respiration rates.


Subject(s)
Cell Communication/physiology , Oxygen Consumption/physiology , Phenotype , Single-Cell Analysis/instrumentation , Single-Cell Analysis/methods , Cell Culture Techniques/instrumentation , Cell Line, Transformed , Cell Respiration/physiology , Humans , Linear Models , Microfluidic Analytical Techniques/instrumentation , Microscopy/instrumentation , Microscopy/methods
3.
J Mater Chem ; 2011(48): 19293-192301, 2011 Jan 01.
Article in English | MEDLINE | ID: mdl-23125483

ABSTRACT

Photosynthetic algae and cyanobacteria have been proposed for producing biofuels through a direct photoconversion process. To accelerate the efforts of discovering and screening microbes for biofuel production, sensitive and high throughput methods to measure photosynthetic activity need to be developed. Here we report the development of new ratiometric optical oxygen and pH dual sensors with three emission colors for measuring photosynthetic activities directly. The dual sensor system can measure oxygen (O(2)) generation and pH increase resulted from carbon dioxide (CO(2)) consumption simultaneously. The sensor was prepared by a copolymerization of three monomeric probes, an intra-reference probe (IRP) which does not respond to pH or O(2), a probe for pH sensing (pHS), and an O(2) probe for O(2) sensing (OS) with 2-hydroxyethyl methacrylate (HEMA) and acrylamide (AM). After polymerization, the three probes were chemically immobilized in an ion and O(2) permeable poly(2-hydroxyethyl methacrylate)-co-polyacrylamide (PHEMA-co-PAM) matrix. The resulted sensing films (membranes) exhibited three emission colors with well separated emission spectra, covering blue, green, and red emission windows, under 380 nm light excitation. Responses of the sensors to pH and dissolved O(2) were investigated in buffers and cyanobacterial cell cultures (Synechocystis sp. PCC 6803). In spite of the strong autofluorescence from cyanobacteria, the sensors were able to determine the pH values and dissolved O(2) concentrations accurately and reproducibly. The measured results using the optical sensors were well in accordance with measurements using electrodes with minimal experimental variations. The sensors were further applied for evaluation of photosynthetic activities of Synechocystis sp. PCC 6803 at the exponential and stationary phases. The results were consistent with biological observation that the photosynthetic activity in the exponential phase was higher than that in the stationary phase.

4.
Sens Actuators B Chem ; 150(2): 579-587, 2010 Oct 28.
Article in English | MEDLINE | ID: mdl-21076638

ABSTRACT

Oxygen sensing films were synthesized by a chemical conjugation of functional platinum porphyrin probes in silica gel, polystyrene (PS), and poly(2-hydroxyethyl methacrylate) (PHEMA) matrices. Responses of the sensing films to gaseous oxygen and dissolved oxygen were studied and the influence of the matrices on the sensing behaviors was investigated. Silica gel films had the highest fluorescence intensity ratio from deoxygenated to oxygenated environments and the fastest response time to oxygen. PHEMA films had no response to gaseous oxygen, but had greater sensitivity and a faster response time for dissolved oxygen than those of PS films. The influence of matrices on oxygen response, sensitivity and response time was discussed. The influence is most likely attributed to the oxygen diffusion abilities of the matrices. Since the probes were chemically immobilized in the matrices, no leaching of the probes was observed from the sensing films when applied in aqueous environment. One sensing film made from the PHEMA matrix was used to preliminarily monitor the oxygen consumption of Escherichia coli (E. coli) bacteria. E. coli cell density and antibiotics ampicillin concentration dependent oxygen consumption was observed, indicating the potential application of the oxygen sensing film for biological application.

5.
Biomaterials ; 31(29): 7411-22, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20619451

ABSTRACT

A series of new naphthalimide derivatives were synthesized and studied. Three of the materials (SM1, SM2, and SM3) possess methacrylate(s) moieties as pH sensor monomers, enabling these compounds to be polymerized with other monomers for thin film preparation for extracellular pH sensing. Herein, poly(2-hydroxyethyl methacrylate)-co-poly(acrylamide) (PHEMA-co-PAM) was chosen as the polymer matrix. Structure influences on pH responses and pK(a) values were studied. The film P3 composed of the sensing moiety SM3 has a pK(a) close to the usual biological environmental pH of approximately 7. It was used as an extracellular pH sensor to monitor pH change during the metabolism of prokaryotic Escherichia coli (E. coil). On the other hand, the three sensor monomers are new intracellular biomarkers to sense lysosomes of eukaryotic cells since (1) their pK(a) values are in a range of 5.9-6.8; (2) their emission intensities at acidic conditions (such as at pH 5) are much stronger than those at a neutral condition of pH 7; (3) lysosomes range in size from 0.1 to 1.2 mum in diameter with pH ranging from 4.5 to 5.0, which is much more acidic than the pH value of the cytoplasm (usually with a pH value of approximately 7.2); and (4) the acidity of lysosomes enables a protonation of the amino groups of the pH probes making the sensors emit brightly in acidic organelles by inhibiting the photo-induced electron transfer from the amino groups to the fluorophores. Lysosome sensing was demonstrated using live human brain glioblastoma U87MG cell line, human cervical cancer HeLa cell line, and human esophagus premalignant CP-A and CP-D cell lines by observations of small acidic spherical organelles (lysosomes) and significant colocalizations (82-95%) of the sensors with a commercially available lysosome-selective staining probe LysoTracker Red under confocal fluorescence microscopy.


Subject(s)
Naphthalimides/chemistry , Optical Devices , Cell Line, Tumor , HeLa Cells , Humans , Hydrogen-Ion Concentration , Models, Theoretical
6.
Adv Biosci Biotechnol ; 5(5): 398-408, 2010 Dec 01.
Article in English | MEDLINE | ID: mdl-21546993

ABSTRACT

Oxygen consumption is a fundamental component of metabolic networks, mitochondrial function, and global carbon cycling. To date there is no method available that allows for replicate measurements on attached and unattached biological samples without compensation for extraneous oxygen leaking into the system. Here we present the Respiratory Detection System, which is compatible with virtually any biological sample. The RDS can be used to measure oxygen uptake in microliter-scale volumes with a reversibly sealed sample chamber, which contains a porphyrin-based oxygen sensor. With the RDS, one can maintain a diffusional seal for up to three hours, allowing for the direct measurement of respiratory function of samples with fast or slow metabolic rates. The ability to easily measure oxygen uptake in small volumes with small populations or dilute samples has implications in cell biology, environmental biology, and clinical diagnostics.

7.
IEEE Trans Autom Sci Eng ; 5(1): 32-42, 2008 Jan 01.
Article in English | MEDLINE | ID: mdl-21057593

ABSTRACT

A novel system that has enabled the measurement of single-cell oxygen consumption rates is presented. The experimental apparatus includes a temperature controlled environmental chamber, an array of microwells etched in glass, and a lid actuator used to seal cells in the microwells. Each microwell contains an oxygen sensitive platinum phosphor sensor used to monitor the cellular metabolic rates. Custom automation software controls the digital image data collection for oxygen sensor measurements, which are analyzed using an image-processing program to yield the oxygen concentration within each microwell versus time. Two proof-of-concept experiments produced oxygen consumption rate measurements for A549 human epithelial lung cancer cells of 5.39 and 5.27 fmol/min/cell, closely matching published oxygen consumption rates for bulk A549 populations.

8.
Opt Express ; 15(17): 10681-9, 2007 Aug 20.
Article in English | MEDLINE | ID: mdl-19547422

ABSTRACT

A digital light modulation microscope (DLMM) that utilizes a digital micromirror device (DMD) on an epifluorescence microscope has been developed to modulate excitation light in spatial and temporal domains for phosphorescence lifetime detection. Local O2 concentration can be inferred through the detected lifetime around an O2-quenching phosphorescent porphyrin microsensor. Combined with microsensor arrays, the DLMM can sequentially address light to each microsensor element to construct a discrete lifetime image or O2 distribution. In contrast to conventional phosphorescence lifetime imaging, the new method eliminates the need for a pulsed light source and a time-gated camera. To demonstrate O2 sensing with lab-on-a-chip devices, an array of 150-mum-diameter micro-wells coated with phosphorescent porphyrin were observed. The locations of the sensor elements were automatically identified though image analysis. The goal of this platform is to measure the O2 consumption of individual cells trapped in the microwells.

9.
Sens Actuators A Phys ; 138(1): 179-186, 2007 Jul 20.
Article in English | MEDLINE | ID: mdl-19551159

ABSTRACT

A common micromixer design strategy is to generate interleaved flow topologies to enhance diffusion. However, problems with these designs include complicated structures and dead volumes within the flow fields. We present an active micromixer using a resonating piezoceramic/silicon composite diaphragm to generate acoustic streaming flow topologies. Circulation patterns are observed experimentally and correlate to the resonant mode shapes of the diaphragm. The dead volumes in the flow field are eliminated by rapidly switching from one discrete resonant mode to another (i.e., resonant mode-hop). Mixer performance is characterized by mixing buffer with a fluorescence tracer containing fluorescein. Movies of the mixing process are analyzed by converting fluorescent images to two-dimensional fluorescein concentration distributions. The results demonstrate that mode-hopping operation rapidly homogenized chamber contents, circumventing diffusion-isolated zones.

SELECTION OF CITATIONS
SEARCH DETAIL
...