Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Respir Physiol Neurobiol ; 194: 15-22, 2014 Apr 01.
Article in English | MEDLINE | ID: mdl-24468468

ABSTRACT

Validation of respiratory inductive plethysmography (LifeShirt system) (RIPLS) for tidal volume (VT), minute ventilation (V˙E), and respiratory frequency (fB) was performed among people with untreated obesity hypoventilation syndrome (OHS) and controls. Measures were obtained simultaneously from RIPLS and a spirometer during two tests, and compared using Bland Altman analysis. Among 13 OHS participants (162 paired measures), RIPLS-spirometer agreement was unacceptable for VT: mean difference (MD) 3 mL (1%); limits of agreement (LOA) -216 to 220 mL (±36%); V˙E MD 0.1 L min(-1) (2%); LOA -4.1 to 4.3 L min(-1) (±36%); and fB: MD 0.2 br min(-1) (2%); LOA -4.6 to 5.0 br min(-1) (±27%). Among 13 controls (197 paired measures), RIPLS-spirometer agreement was acceptable for fB: MD -0.1 br min(-1) (-1%); LOA -1.2 to 1.1 br min(-1) (±12%), but unacceptable for VT: MD 5 mL (1%); LOA -160 to 169 mL (±20%) and V˙E: MD 0.1 L min(-1) (1%); LOA -1.4 to 1.5 L min(-1) (±20%). RIPLS produces valid measures of fB among controls but not OHS patients, and is not valid for quantifying respiratory volumes among either group.


Subject(s)
Obesity Hypoventilation Syndrome/diagnosis , Plethysmography/instrumentation , Female , Humans , Male , Middle Aged , Obesity Hypoventilation Syndrome/physiopathology , Respiration , Spirometry , Tidal Volume , Waist Circumference
2.
Respir Physiol Neurobiol ; 188(2): 165-71, 2013 Aug 15.
Article in English | MEDLINE | ID: mdl-23732508

ABSTRACT

This prospective study investigated the validity of arterialised-venous blood gases (AVBG) for estimating arterial carbon dioxide P CO2, pH and bicarbonate (HCO3(-)) in people with obesity hypoventilation syndrome (OHS). AVBGs were obtained from an upper limb vein, after heating the skin at 42-46°C. Arterial blood gas (ABG) and AVBG samples were taken simultaneously and compared using Bland Altman analysis. Between-group differences were assessed with independent t-tests or Mann-Whitney U tests. Forty-two viable paired samples were analysed, including 27 paired samples from 15 OHS participants, and 15 paired samples from 16 controls. AVBG-ABG agreement was not different between groups, or between dorsal hand, forearm and antecubital AVBG sampling sites, and was clinically acceptable for P Co2: mean difference (MD) 0.4 mmHg (0.9%), limits of agreement (LOA) -2.7-3.6 mmHg (± 6.6%); pH: MD -0.008 (-0.1%), LOA -0.023-0.008 (± 0.2%); and HCO3(-): MD -0.3 mmol L(-1) (-1.0%), LOA -1.8-1.2 mmol L(-1) (± 5.3%). AVBG provides valid measures of [Formula: see text] , pH, and HCO3(-) in OHS.


Subject(s)
Bicarbonates/blood , Carbon Dioxide/blood , Obesity Hypoventilation Syndrome/blood , Adult , Arteries , Blood Gas Analysis , Female , Humans , Hydrogen-Ion Concentration , Male , Middle Aged , Reproducibility of Results , Statistics, Nonparametric , Veins
SELECTION OF CITATIONS
SEARCH DETAIL
...