1.
Front Surg ; 9: 976944, 2022.
Article in English | MEDLINE | ID: mdl-36176339

ABSTRACT

Objective: We have encountered broken or damaged polypropylene sutures (Prolene®) at the anastomotic sites during aortic reoperations. Because a surgical sealant, bovine serum albumin-glutaraldehyde (BioGlue®), was used in previous aortic surgery in some of these cases, we undertook this in vitro study to evaluate whether the use of BioGlue® was associated with breakage of polypropylene sutures at the aortic anastomosis. Materials and methods: The broken polypropylene sutures, anastomotic sites and aortic tissue at the location of suture breakage were visually inspected and evaluated intraoperatively. Six human cadaveric aortic samples were incised circumferentially and anastomosed proximally to a valved conduit with running 4-0 polypropylene sutures (Prolene®). In the test group (n = 3), BioGlue® was applied directly to the Prolene® sutures at the anastomotic sites, while in the control group (n = 3) the anastomoses were not sealed with any surgical adhesive. The six samples were immersed in Dulbecco's phosphate buffered saline solution and mounted on a M-6 Six Position Heart Valve Durability Testing System and tested up to 120 million cycles for a 2-year period. During and upon completion of the testing, the integrity of Prolene® sutures, the anastomosis and aortic tissues was regularly assessed by visual inspection. Results: Intraoperative findings included a stretched and thin aortic wall (some with thrombus), a small cleft between the aortic tissue and the Dacron vascular graft. An excessive amount of BioGlue® was often found around the anastomosis, with cracking material, but no signs of mechanical damage were observed in these cases. Upon visual inspection during and after in vitro testing, there was no apparent damage to the polypropylene sutures on the interior or exterior of the aortic anastomoses in any of the samples. No difference was observed in the physical integrity of the polypropylene sutures at anastomotic lines, the anastomoses and aortic tissues between the test and control samples. Conclusions: The results of this study suggest that the use of BioGlue® was not associated with breakage of the polypropylene sutures at the anastomotic sites after aortic dissection repair.

2.
J Vasc Surg ; 63(4): 1026-33, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26826055

ABSTRACT

BACKGROUND: In end-stage renal disease patients with central venous obstruction, who have limited vascular access options, the Hemodialysis Reliable Outflow (HeRO) Graft is a new alternative with a lower incidence of complications and longer effective device life compared to tunneled dialysis catheters (TDCs). We undertook an economic analysis of introducing the HeRO Graft in the UK. METHODS: A 1-year cost-consequence decision analytic model was developed comparing management with the HeRO Graft to TDCs from the perspective of the National Health Service in England. The model comprises four 3-month cycles during which the vascular access option either remains functional for hemodialysis or fails, patients can experience access-related infection and device thrombosis, and they can also accrue associated costs. Clinical input data were sourced from published studies and unit cost data from National Health Service 2014-15 Reference Costs. RESULTS: In the base case, a 100-patient cohort managed with the HeRO Graft experienced 6 fewer failed devices, 53 fewer access-related infections, and 67 fewer device thromboses compared to patients managed with TDCs. Although the initial device and placement costs for the HeRO Graft are greater than those for TDCs, savings from the lower incidence of device complications and longer effective device patency reduces these costs. Overall net annual costs are £2600 for each HeRO Graft-managed patient compared to TDC-managed patients. If the National Health Service were to reimburse hemodialysis at a uniform rate regardless of the type of vascular access, net 1-year savings of £1200 per patient are estimated for individuals managed with the HeRO Graft. CONCLUSIONS: The base case results showed a marginal net positive cost associated with vascular access with the HeRO Graft compared with TDCs for the incremental clinical benefit of reductions in patency failures, device-related thrombosis, and access-related infection events in a patient population with limited options for dialysis vascular access.


Subject(s)
Blood Vessel Prosthesis Implantation/economics , Blood Vessel Prosthesis/economics , Catheterization, Central Venous/economics , Catheters, Indwelling/economics , Central Venous Catheters , Health Care Costs , Kidney Failure, Chronic/economics , Kidney Failure, Chronic/therapy , Renal Dialysis/economics , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Catheter Obstruction/economics , Catheter Obstruction/etiology , Catheter-Related Infections/economics , Catheter-Related Infections/microbiology , Catheter-Related Infections/therapy , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/instrumentation , Catheters, Indwelling/adverse effects , Cost-Benefit Analysis , Decision Support Techniques , England , Graft Occlusion, Vascular/economics , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/therapy , Humans , Kidney Failure, Chronic/diagnosis , Models, Economic , Prosthesis Design , Prosthesis Failure , Prosthesis-Related Infections/economics , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/therapy , State Medicine/economics , Thrombosis/economics , Thrombosis/etiology , Thrombosis/therapy , Time Factors , Treatment Outcome , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL
...