1.
Heart Rhythm ; 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38490597

ABSTRACT

BACKGROUND: Many patients with mildly to moderately reduced left ventricular ejection fraction (LVEF) who require permanent pacemaker (PPM) implantation do not have a concurrent indication for implantable cardioverter-defibrillator (ICD) therapy. However, the risk of ventricular tachycardia/ventricular fibrillation (VT/VF) in this population is unknown. OBJECTIVE: The aim of this study was to describe the risk of VT/VF after PPM implantation in patients with mildly to moderately reduced LVEF. METHODS: Retrospective analysis was performed of 243 patients with LVEF between 35% and 49% who underwent PPM placement and did not meet indications for an ICD. The primary end point was occurrence of sustained VT/VF. Competing risks regression was performed to calculate subhazard ratios for the primary end point. RESULTS: Median follow-up was 27 months; 73% of patients were male, average age was 79 ± 10 years, average LVEF was 42% ± 4%, and 70% were New York Heart Association class II or above. Most PPMs were implanted for sick sinus syndrome (34%) or atrioventricular block (50%). Of 243 total patients, 11 (4.5%) met the primary end point of VT/VF. Multivessel coronary artery disease (CAD) was associated with significantly higher rates of VT/VF, with a subhazard ratio of 5.4 (95% CI, 1.5-20.1; P = .01). Of patients with multivessel CAD, 8 of 82 (9.8%) patients met the primary end point for an annualized risk of 4.3% per year. CONCLUSION: Patients with mildly to moderately reduced LVEF and multivessel CAD undergoing PPM implantation are at increased risk for the development of malignant ventricular arrhythmias. Patients in this population may benefit from additional risk stratification for VT/VF and consideration for upfront ICD implantation.

3.
J Interv Card Electrophysiol ; 67(1): 203-210, 2024 Jan.
Article in English | MEDLINE | ID: mdl-36952090

ABSTRACT

OBJECTIVES: We investigated characteristics of left atrial conduction in patients with HCM, paroxysmal AF and normal bipolar voltage. BACKGROUND: Patients with hypertrophic cardiomyopathy (HCM) exhibit abnormal cardiac tissue arrangement. The incidence of atrial fibrillation (AF) is increased fourfold in patients with HCM and confers a fourfold increased risk of death. Catheter ablation is less effective in HCM, with twofold increased risk of AF recurrence. The mechanisms of AF perpetuation in HCM are poorly understood. METHODS: We analyzed 20 patients with HCM and 20 controls presenting for radiofrequency ablation of paroxysmal AF normal left atrial voltage(> 0.5 mV). Intracardiac electrograms were extracted from the CARTO mapping system and analyzed using Matlab/Python code interfacing with Core OpenEP software. Conduction velocity maps were calculated using local activation time gradients. RESULTS: There were no differences in baseline demographics, atrial size, or valvular disease between HCM and control patients. Patients with HCM had significantly reduced atrial conduction velocity compared to controls (0.44 ± 0.17 vs 0.56 ± 0.10 m/s, p = 0.01), despite no significant differences in bipolar voltage amplitude (1.23 ± 0.38 vs 1.20 ± 0.41 mV, p = 0.76). There was a statistically significant reduction in conduction velocity in the posterior left atrium in HCM patients relative to controls (0.43 ± 0.18 vs 0.58 ± 0.10 m/s, p = 0.003), but not in the anterior left atrium (0.46 ± 0.17 vs 0.55 ± 0.10 m/s, p = 0.05). There was a significant association between conduction velocity and interventricular septal thickness (slope = -0.013, R2 = 0.13, p = 0.03). CONCLUSIONS: Atrial conduction velocity is significantly reduced in patients with HCM and paroxysmal AF, possibly contributing to arrhythmia persistence after catheter ablation.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiomyopathy, Hypertrophic , Catheter Ablation , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Heart Atria/diagnostic imaging , Heart Atria/surgery , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/complications , Atrial Appendage/surgery , Catheter Ablation/adverse effects
4.
Phys Rev E ; 108(3-2): 035002, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37849112

ABSTRACT

Thin sheets respond to confinement by smoothly wrinkling or by focusing stress into small, sharp regions. From engineering to biology, geology, textiles, and art, thin sheets are packed and confined in a wide variety of ways, and yet fundamental questions remain about how stresses focus and patterns form in these structures. Using experiments and molecular dynamics simulations, we probe the confinement response of circular sheets, flattened in their central region and quasistatically drawn through a ring. Wrinkles develop in the outer, free region, then are replaced by a truncated cone, which forms in an abrupt transition to stress focusing. We explore how the force associated with this event, and the number of wrinkles, depend on geometry. Additional cones sequentially pattern the sheet until axisymmetry is recovered in most geometries. The cone size is sensitive to in-plane geometry. We uncover a coarse-grained description of this geometric dependence, which diverges depending on the proximity to the asymptotic d-cone limit, where the clamp size approaches zero. This paper contributes to the characterization of general confinement of thin sheets, while broadening the understanding of the d cone, a fundamental element of stress focusing, as it appears in realistic settings.

5.
Heart Rhythm O2 ; 4(7): 440-447, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37520016

ABSTRACT

Background: High-power, short-duration (HPSD) radiofrequency ablation (RFA) reduces procedure time; however, safety and efficacy thresholds vary with catheter design. Objective: The study sought to determine optimal HPSD ablation conditions with a novel flexible-tipped, contact force-sensing RFA catheter. Methods: RFA lesions were created in thigh muscle (16 swine) over a range of conditions (51-82 W, 2-40 g, 8-40 mL/min irrigation). An intracardiac study was performed (12 swine) to characterize steam pop thresholds. Lesions were created in a second intracardiac study (14 swine, n = 290 pulmonary vein isolation [PVI] lesions) with combinations of radiofrequency power, duration, and contact force. PVI was tested, animals were sacrificed, and lesions were measured. Results: The likelihood of coagulation formation in the thigh model was <20% when power was ≤79 W, when contact force was ≤40 g, when duration was ≤11 seconds, and when irrigation rates were 8 to 40 mL/min. The impact of contact force on lesion safety and efficacy was more pronounced using HPSD (60 W/8 seconds) compared with conventional ablation (30 W/45 seconds) (P = .038). During PVI, focal atrial lesions ranged in width from 4.2 to 12.5 mm and were transmural 80.8% of the time. PVI was achieved in 13 of 14 veins. Logistic regression identified that the optimal parameters for radiofrequency application were 60 to 70 W with a duration <8 seconds and <15 g contact force. Conclusions: Optimal HPSD lesions with this this flexible-tipped, force-sensing RFA catheter were created at 60 to 70 W for <8 seconds with <15 g contact force. Chronic studies are ongoing to assess radiofrequency parameter refinements and long-term lesion durability using these conditions.

6.
Phys Rev Lett ; 130(14): 148201, 2023 Apr 07.
Article in English | MEDLINE | ID: mdl-37084420

ABSTRACT

A collection of thin structures buckle, bend, and bump into each other when confined. This contact can lead to the formation of patterns: hair will self-organize in curls; DNA strands will layer into cell nuclei; paper, when crumpled, will fold in on itself, forming a maze of interleaved sheets. This pattern formation changes how densely the structures can pack, as well as the mechanical properties of the system. How and when these patterns form, as well as the force required to pack these structures is not currently understood. Here we study the emergence of order in a canonical example of packing in slender structures, i.e., a system of parallel confined elastic beams. Using tabletop experiments, simulations, and standard theory from statistical mechanics, we predict the amount of confinement (growth or compression) of the beams that will guarantee a global system order, which depends only on the initial geometry of the system. Furthermore, we find that the compressive stiffness and stored bending energy of this metamaterial are directly proportional to the number of beams that are geometrically frustrated at any given point. We expect these results to elucidate the mechanisms leading to pattern formation in these kinds of systems and to provide a new mechanical metamaterial, with a tunable resistance to compressive force.

7.
Heart Rhythm ; 20(6): 808-814, 2023 06.
Article in English | MEDLINE | ID: mdl-36863636

ABSTRACT

BACKGROUND: Established electroanatomic mapping techniques for substrate mapping for ventricular tachycardia (VT) ablation includes voltage mapping, isochronal late activation mapping (ILAM), and fractionation mapping. Omnipolar mapping (Abbott Medical, Inc.) is a novel optimized bipolar electrogram creation technique with integrated local conduction velocity annotation. The relative utilities of these mapping techniques are unknown. OBJECTIVE: The purpose of this study was to evaluate the relative utility of various substrate mapping techniques for the identification of critical sites for VT ablation. METHODS: Electroanatomic substrate maps were created and retrospectively analyzed in 27 patients in whom 33 VT critical sites were identified. RESULTS: Both abnormal bipolar voltage and omnipolar voltage encompassed all critical sites and were observed over a median of 66 cm2 (interquartile range [IQR] 41.3-86 cm2) and 52 cm2 (IQR 37.7-65.5 cm2), respectively. ILAM deceleration zones were observed over a median of 9 cm2 (IQR 5.0-11.1 cm2) and encompassed 22 critical sites (67%), while abnormal omnipolar conduction velocity (CV <1 mm/ms) was observed over 10 cm2 (IQR 5.3-16.6 cm2) and identified 22 critical sites (67%), and fractionation mapping was observed over a median of 4 cm2 (IQR 1.5-7.6 cm2) and encompassed 20 critical sites (61%). The mapping yield was the highest for fractionation + CV (2.1 critical sites/cm2) and least for bipolar voltage mapping (0.5 critical sites/cm2). CV identified 100% of critical sites in areas with a local point density of >50 points/cm2. CONCLUSION: ILAM, fractionation, and CV mapping each identified distinct critical sites and provided a smaller area of interest than did voltage mapping alone. The sensitivity of novel mapping modalities improved with greater local point density.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Retrospective Studies , Electrophysiologic Techniques, Cardiac/methods , Catheter Ablation/methods
8.
J Cardiovasc Electrophysiol ; 34(4): 942-946, 2023 04.
Article in English | MEDLINE | ID: mdl-36738141

ABSTRACT

INTRODUCTION: Radiofrequency ablation (RFA) slow pathway modification for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is traditionally performed using a 4-mm nonirrigated (NI) RF ablation catheter. Slow pathway modification using irrigated, contact-force sensing (ICFS) RFA catheters has been described in case reports, but the outcomes have not been systematically evaluated. METHODS: Acute procedural outcomes of 200 consecutive patients undergoing slow pathway modification for AVNRT were analyzed. A 3.5-mm ICFS RFA catheter (ThermoCool SmartTouch STSF, Biosense Webster, Inc.) was utilized in 134 patients, and a 4-mm NI RFA catheter (EZ Steer, Biosense Webster, Inc.) was utilized in 66 patients. Electroanatomic maps were retrospectively analyzed in a blinded fashion to determine the proximity of ablation lesions to the His region. RESULTS: The baseline characteristics of patients in both groups were similar. Total RF time was significantly lower in the ICFS group compared to the NI group (5.53 ± 4.6 vs. 6.24 ± 4.9 min, p = 0.03). Median procedure time was similar in both groups (ICFS, 108.0 (87.5-131.5) min vs. NI, 100.0 (85.0-125.0) min; p = 0.2). Ablation was required in closer proximity to the His region in the NI group compared to the ICFS group (14.4 ± 5.9 vs. 16.7 ± 6.4 mm, respectively, p = 0.01). AVNRT was rendered noninducible in all patients, and there was no arrhythmia recurrence during follow-up in both groups. Catheter ablation was complicated by AV block in one patient in the NI group. CONCLUSION: Slow pathway modification for catheter ablation of AVNRT using an ICFS RFA catheter is feasible, safe, and may facilitate shorter duration ablation while avoiding ablation in close proximity to the His region.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Tachycardia, Atrioventricular Nodal Reentry , Humans , Retrospective Studies , Catheters
9.
J Cardiovasc Electrophysiol ; 34(4): 800-807, 2023 04.
Article in English | MEDLINE | ID: mdl-36738147

ABSTRACT

INTRODUCTION: Radiofrequency ablation technology for treating atrial fibrillation (AF) has evolved rapidly over the past decade. We investigated the impact of technological and procedural advances on procedure times and ablation outcomes at a major academic medical center over a 10-year period. METHODS: Clinical data was collected from patients who presented to NYU Langone Health between 2011 and 2021 for a first-time AF ablation. Time to redo AF ablation or direct current cardioversion (DCCV) for recurrent AF during a 3-year follow-up period was determined and correlated with ablation technology and practices, antiarrhythmic medications, and patient comorbid conditions. RESULTS: From 2011 to 2021, the cardiac electrophysiology lab adopted irrigated-contact force ablation catheters, high-power short duration ablation lesions, steady-pacing, jet ventilation, and eliminated stepwise linear ablation for AF ablation. During this time the number of first time AF ablations increased from 403 to 1074, the percentage of patients requiring repeat AF-related intervention within 3-years of the index procedure dropped from 22% to 14%, mean procedure time decreased from 271 ± 65 to 135 ± 36 min, and mean annual major adverse event rate remained constant at 1.1 ± 0.5%. Patient comorbid conditions increased during this time period and antiarrhythmic use was unchanged. CONCLUSION: Rates of redo-AF ablation or DCCV following an initial AF ablation at a single center decreased 36% over a 10-year period. Procedural and technological changes likely contributed to this improvement, despite increased AF related comorbidities.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Time Factors , Catheter Ablation/methods
10.
Gen Dent ; 71(2): 59-63, 2023.
Article in English | MEDLINE | ID: mdl-36825975

ABSTRACT

The purpose of this study was to compare the performances of 5 different instruments in measuring the irradiance of light-curing units (LCUs). A novel spectrometer-trained radiometer (CheckUp), 2 conventional chairside radiometers (Bluephase Meter I and Bluephase Meter II), and 2 devices considered to be gold standards for measuring irradiance (an integrating sphere spectrometer and a thermopile sensor) were used to evaluate 7 LCUs. The irradiance of each LCU was measured 10 times with each meter. Data were analyzed using linear regression analysis and a 1-way analysis of variance with Tukey post hoc test (α = 0.05). The mean irradiance values of the LCUs differed significantly depending on which meter was used for measurement (P < 0.05). Bivariate regression analysis demonstrated that the highest correlations in the irradiance values were found between the CheckUp meter and both the integrating sphere (r2 = 0.980) and the thermopile (r2 = 0.933). The absolute mean (SD) percentage deviation between irradiance measured by the CheckUp instrument and irradiance measured by the other meters was 7.2% (2.0%) for the integrating sphere, 7.0% (3.6%) for the thermopile, 21.5% (16.1%) for Bluephase Meter I, and 13.1% (7.1%) for Bluephase Meter II. Compared with the 2 conventional chairside radiometers, the CheckUp meter provided the highest correlation with and lowest absolute percentage deviation from the irradiance measured by the gold standard spectrometers.


Subject(s)
Curing Lights, Dental , Light-Curing of Dental Adhesives , Humans , Radiometry , Composite Resins , Materials Testing
11.
J Cardiovasc Electrophysiol ; 34(3): 575-582, 2023 03.
Article in English | MEDLINE | ID: mdl-36511474

ABSTRACT

INTRODUCTION: Patients with HIV infection have increased risk of atrial fibrillation, but the pathophysiologic mechanisms and the utility of catheter ablation in this population are not well-studied. We aimed to characterize outcomes of atrial fibrillation ablation and left atrial substrate in patients with HIV. METHODS: The study was a retrospective propensity score-matched analysis of patients with and without HIV undergoing atrial fibrillation ablation. A search was performed in the electronic medical record for all patients with HIV who received initial atrial fibrillation ablation from 2011 to 2020. After calculating propensity scores for HIV, matching was performed with patients without HIV by using nearest-neighbor matching without replacement in a 1:2 ratio. The primary outcome was freedom from atrial arrhythmia and secondary outcomes were freedom from atrial fibrillation, freedom from atrial tachycardia, and freedom from repeat ablation, compared by log-rank analysis. The procedures of patients with HIV who underwent repeat ablation at our institution were further analyzed for etiology of recurrence. To further characterize the left atrial substrate, a subsequent case-control analysis was then performed for a set of randomly chosen 10 patients with HIV matched with 10 without HIV to compare minimum and maximum voltage at nine pre-specified regions of the left atrium. RESULTS: Twenty-seven patients with HIV were identified. All were prescribed antiretroviral therapy at time of ablation. These patients were matched with 54 patients without HIV by propensity score. 86.4% of patients with HIV and 76.9% of controls were free of atrial fibrillation or atrial tachycardia at 1 year (p = .509). Log-rank analysis showed no difference in freedom from atrial arrhythmia (p value .971), atrial fibrillation (p-value .346), atrial tachycardia (p value .306), or repeat ablation (p value .401) after initial atrial fibrillation ablation in patients with HIV compared to patients without HIV. In patients with HIV with recurrent atrial fibrillation, the majority had pulmonary vein reconnection (67%). There were no significant differences in minimum or maximum voltage at any of the nine left atrial regions between the matched patients with and without HIV. CONCLUSIONS: Ablation to treat atrial fibrillation in patients with HIV, but without overt AIDS is frequently successful therapy. The majority of patients with recurrence of atrial fibrillation had pulmonary vein reconnection, suggesting infrequent nonpulmonary vein substrate. In this population, the left atrial voltage in patients with HIV is similar to that of patients without HIV. These findings suggest that the pulmonary veins remain a critical component to the initiation and maintenance of atrial fibrillation in patients with HIV.


Subject(s)
Atrial Fibrillation , Catheter Ablation , HIV Infections , Pulmonary Veins , Tachycardia, Supraventricular , Humans , Atrial Fibrillation/surgery , Retrospective Studies , HIV Infections/complications , HIV Infections/surgery , Treatment Outcome , Heart Atria , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Recurrence
12.
Soft Matter ; 18(43): 8262-8270, 2022 Nov 09.
Article in English | MEDLINE | ID: mdl-36278291

ABSTRACT

String and grains can be combined to create structures capable of bearing significant loads. In this work, we prepare columns and beams through a layer-by-layer deposition of granular matter and loops of fiber strings, and characterize their mechanical properties. The loops cause the grains to jam, and the inter-grain contact leads to a Hertzian-like constitutive response. Initially, one force chain that propagates vertically through the column bears most of the compressive load. As the magnitude of the load is increased, more force chains form in the column, which act in parallel to increase its stiffness, akin to a "super-Hertzian" regime. Applying a compressive prestress enables the structures to withstand shear, enabling the fabrication of cantilevered beams. This work provides a mechanical framework to use elastogranular jamming to create rapid, reusable infrastructure components, such as columns, beams, and arches from inexpensive, commonplace materials, such as rocks and string.

13.
Leadersh Health Serv (Bradf Engl) ; ahead-of-print(ahead-of-print)2022 09 23.
Article in English | MEDLINE | ID: mdl-36129260

ABSTRACT

PURPOSE: This study aims to demonstrate how service providers, service users and their families should be able to share the co-leadership, co-auspicing, co-ownership, and co-governance, of a the mental health-care ecosystem, at every level, as it develops upwards and wider, in a process of inclusivity, conviviality and polyphonic discourse, via the overlapping phases of co-creativity, codesign, co-production, co-delivery, co-evaluation, co-research and co-replication, to achieve outcomes of co-communal or organisational well-being. DESIGN/METHODOLOGY/APPROACH: "Co-design" is shorthand code for encouraging multiple pathways and trajectories toward forming and sustaining a sparkling web or vibrant network of inclusive opportunities for stakeholder participation and a collaborative partnership in organizational development, in these circumstances, for more effective mental health services (MHSs). FINDINGS: In a co-design framework, all partners should be entitled to expect and "to have and to hold" an ongoing equal stake, voice and power in the discourse from start to finish, in a bottom-up process which is fostered by an interdisciplinary leadership group, providing the strong foundation or nutrient-rich and well-watered soil and support from which a shared endeavor can grow, blossom and generate the desired fruit in ample quality and quantity. ORIGINALITY/VALUE: The authors should be working toward co-design and co-production of contemporary MHSs in a mental health-care ecosystem.


Subject(s)
Leadership , Mental Health Services , Ecosystem , Humans , Mental Health , Soil
15.
Heart Rhythm ; 19(5): 759-767, 2022 05.
Article in English | MEDLINE | ID: mdl-35038570

ABSTRACT

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is the most prevalent inherited cardiomyopathy. The implantable cardioverter-defibrillator (ICD) is important for prevention of sudden cardiac death (SCD) in patients at high risk. In recent years, the subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as a viable alternative to the transvenous implantable cardioverter-defibrillator (TV-ICD). The S-ICD does not require intravascular access; however, it cannot provide antitachycardia pacing (ATP) therapy. OBJECTIVE: The purpose of this study was to assess the real-world incidence of ICD therapy in patients with HCM implanted with TV-ICD vs S-ICD. METHODS: We compared the incidence of ATP and shock therapies among all HCM patients with S-ICD and TV-ICD enrolled in the Boston Scientific ALTITUDE database. Cumulative Kaplan-Meier incidence was used to compare therapy-free survival, and Cox proportional hazard ratios were calculated. We performed unmatched as well as propensity match analyses. RESULTS: We included 2047 patients with TV-ICD and 626 patients with S-ICD, followed for an average of 1650.5 ± 1038.5 days and 933.4 ± 550.6 days, respectively. Patients with HCM and TV-ICD had a significantly higher rate of device therapy compared to those with S-ICD (32.7 vs 14.5 therapies per 100 patient-years, respectively; P <.001), driven by a high incidence of ATP therapy in the TV-ICD group, which accounted for >67% of therapies delivered. Shock incidence was similar between groups, both in the general and the matched cohorts. CONCLUSION: Patients with HCM and S-ICD had a significantly lower therapy rate than patients with TV-ICD without difference in shock therapy, suggesting potentially unnecessary ATP therapy. Empirical ATP programming in patients with HCM may be unbeneficial.


Subject(s)
Cardiomyopathy, Hypertrophic , Defibrillators, Implantable , Adenosine Triphosphate , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Humans , Treatment Outcome
16.
Eur Phys J E Soft Matter ; 45(1): 3, 2022 Jan 13.
Article in English | MEDLINE | ID: mdl-35024982

ABSTRACT

In bistable actuators and other engineered devices, a homogeneous stimulus (e.g., mechanical, chemical, thermal, or magnetic) is often applied to an entire shell to initiate a snap-through instability. In this work, we demonstrate that restricting the active area to the shell boundary allows for a large reduction in its size, thereby decreasing the energy input required to actuate the shell. To do so, we combine theory with 1D finite element simulations of spherical caps with a non-homogeneous distribution of stimulus-responsive material. We rely on the effective curvature stimulus, i.e., the natural curvature induced by the non-mechanical stimulus, which ensures that our results are entirely stimulus-agnostic. To validate our numerics and demonstrate this generality, we also perform two sets of experiments, wherein we use residual swelling of bilayer silicone elastomers-a process that mimics differential growth-as well as a magneto-elastomer to induce curvatures that cause snap-through. Our results elucidate the underlying mechanics, offering an intuitive route to optimal design for efficient snap-through.


Subject(s)
Elastomers
17.
J Interv Card Electrophysiol ; 63(1): 97-101, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33543350

ABSTRACT

PURPOSE: Catheter ablation procedures for atrial fibrillation (AF) were significantly curtailed during the peak of coronavirus disease 2019 (COVID-19) pandemic to conserve healthcare resources and limit exposure. There is little data regarding peri-procedural outcomes of medical procedures during the COVID-19 pandemic. We enacted protocols to safely reboot AF ablation while limiting healthcare resource utilization. We aimed to evaluate acute and subacute outcomes of protocols instituted for reboot of AF ablation during the COVID-19 pandemic. METHODS: Perioperative healthcare utilization and acute procedural outcomes were analyzed for consecutive patients undergoing AF ablation under COVID-19 protocols (2020 cohort; n=111) and compared to those of patients who underwent AF ablation during the same time period in 2019 (2019 cohort; n=200). Newly implemented practices included preoperative COVID-19 testing, selective transesophageal echocardiography (TEE), utilization of venous closure, and same-day discharge when clinically appropriate. RESULTS: Pre-ablation COVID-19 testing was positive in 1 of 111 patients. There were 0 cases ablation-related COVID-19 transmission and 0 major complications in either cohort. Pre-procedure TEE was performed in significantly fewer 2020 cohort patients compared to the 2019 cohort patients (68.4% vs. 97.5%, p <0.001, respectively) despite greater prevalence of persistent arrhythmia in the 2020 cohort. Same-day discharge was achieved in 68% of patients in the 2020 cohort, compared to 0% of patients in the 2019 cohort. CONCLUSIONS: Our findings demonstrate the feasibility of safe resumption of complex electrophysiology procedures during the COVID-19 pandemic, reducing healthcare utilization and maintaining quality of care. Protocols instituted may be generalizable to other types of procedures and settings.


Subject(s)
Atrial Fibrillation , COVID-19 , Catheter Ablation , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , COVID-19 Testing , Humans , Pandemics , SARS-CoV-2 , Treatment Outcome
18.
J Cardiovasc Electrophysiol ; 33(2): 209-217, 2022 02.
Article in English | MEDLINE | ID: mdl-34911157

ABSTRACT

INTRODUCTION: Prior studies have shown that addition of posterior wall isolation (PWI) may reduce atrial fibrillation recurrence in patients with persistent atrial fibrillation. No data on PWI in paroxysmal AF (pAF) patients with normal left atrial voltage is available, to date. OBJECTIVE: This study sought to evaluate the efficacy of PWI in addition to pulmonary vein isolation (PVI) in patients presenting with pAF and normal left atrial voltage. METHODS: Consecutive patient registry analysis was performed on all patients with pAF and normal left atrial voltage undergoing initial radiofrequency ablation from November 1, 2018 to November 15, 2019. Primary endpoint was recurrence of atrial arrhythmia including AF, atrial tachycardia (AT), or atrial flutter (AFL). RESULTS: A total of 321 patients were studied, 214 in the PVI group and 107 in the PWI + PVI group. Recurrence of any atrial arrhythmia occurred in 18.2% of patients in the PVI group and 16.8% in the PVI + PWI cohort (p = 0.58). At 1 year, recurrence was 14.0% in the PVI group and 15.0% in the PWI + PVI group (p = 0.96). There was a lower AT/AFL recurrence in the PVI + PWI group, not reaching significance (3.7% in the PWI + PVI group vs. 7.9% in PVI group, p = 0.31). Need for carina lesions predicted recurrence in the PVI-only group. CONCLUSIONS: Addition of PWI to PVI in pAF patients undergoing their first ablation did not reduce the frequency of atrial arrhythmia recurrence. This warrants further study in a prospective trial.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
19.
J Atr Fibrillation ; 14(1): 20200485, 2021.
Article in English | MEDLINE | ID: mdl-34950364

ABSTRACT

PURPOSE: Incident atrial fibrillation (AF) is common after cavotricuspid isthmus (CTI) dependent atrial flutter (AFL) ablation. Risk factors for the development of AF post ablation are not well understood. The purpose of this study was to identify patients undergoing CTI ablation for AFL most likely to develop AF. METHODS: Retrospective chart review identified 114 consecutive patients without a history of AF or prior cardiac surgery who underwent typical CTI dependent AFL ablation between December 2013 to November 2018, who also had a complete preoperative transthoracic echocardiogram, and at least 1 year of follow-up at our medical center. We evaluated baseline characteristics, electrophysiology study (EPS) data and echocardiographic data for incidence of AF within 3 years. RESULTS: Incident AF was identified in 46 patients (40%) during 600 + 405 days follow-up. Left atrial volume index (LAVI) was significantly greater in patients who developed AF compared to those that did not (37 ± 12.2 ml/m2 vs 30 ± 13.4 ml/m2, p=.004), with an area under the receiver operator characteristic curve based on the LAVI of 0.7 (p = 0.004). Kaplan-Meier estimated incidence of AF was significantly greater in patients with LAVI ≥ 30 ml/m2 than LAVI < 30 ml/m2 (66% vs 27%, p=0.004). Risk of incident AF in patients with LAVI > 40 mL/m2 was similar to that of LAVI 30-40 ml/m2 (67% vs 63%, respectively, p=0.97). In multivariable analysis LAVI remained the sole independent predictor of incidence AF after CTI AFL ablation. CONCLUSIONS: LAVI ≥ 30 ml/m2 is associated with significantly increased risk of incident AF following CTI ablation for typical AFL. HATCH <2 was notably not an independent predictor of AF after AFL ablation.

20.
Int J Cardiol Heart Vasc ; 37: 100908, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34765721

ABSTRACT

BACKGROUND: There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes. METHODS: Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method. Incidence was compared by device indication, diagnosis type and device type. Cox-regression analysis was used to identify predictors of appropriate shock and device complication. RESULTS: 123 patients with a mean follow up of 6.4 ± 4.8 years were included. The incidence of first appropriate shock was 56.52% vs 24.44%, p < 0.05 for cardiomyopathy and channelopathy patients, despite similar ejection fraction (61% vs 60%, p = 0.6). The incidence of first inappropriate shock was 13.46% vs 56.25%, p < 0.01 for single vs. multi-lead devices. The incidence of first lead complication was higher for multi-lead vs. single lead devices, 43.75% vs. 17.31%, p = 0.04. Patients with an ICD for secondary prevention were more likely to receive an appropriate shock than those with primary prevention indication (HR 2.21, CI 1.07-4.56, p = 0.03). Multi-lead devices were associated with higher risk of inappropriate shock (HR 3.99, CI 1.27-12.52, p = 0.02), with similar appropriate shock risk compared to single lead devices. In 26.5% of patients with dual chamber devices, atrial sensing or pacing was not utilized. CONCLUSION: The rate of appropriate therapies and ICD complications in patients with inherited arrhythmia is high, particularly in cardiomyopathies with multi-lead devices. Risk-benefit ratio should be carefully considered when assessing the indication and type of device in this population.