Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
EJNMMI Phys ; 8(1): 69, 2021 Oct 16.
Article in English | MEDLINE | ID: mdl-34655369

ABSTRACT

PURPOSE: Ventilation-perfusion single-photon emission computed tomography (VP SPECT) plays an important role in pulmonary embolism diagnosis. Rapid results may be obtained using same-day ventilation followed by perfusion imaging, but generally requires careful attention to achieving an optimal count rate ratio (P/V ratio) of ≥ 3:1. This study investigated whether the ratio of counts simultaneously acquired in adjacent primary and Compton scatter energy windows (Eratio) on V SPECT was predictive of final normalised perfusion count rate (PCRnorm) on P SPECT using [99mTc]Tc-macroaggregated albumin (MAA), thus allowing for optimisation of P/V ratios. METHODS: Same-day VP SPECT studies acquired using standard protocols in adult patients during a 2-year period (training dataset) were assessed. Studies were included provided they were acquired with correct imaging parameters, and injection site imaging and laboratory records were available for quality control and normalised count rate corrections. Extraction of DICOM information, and linear regression were performed using custom Python and R scripts. A predictive tool was developed in Microsoft Excel. This tool was then validated using a second (validation) dataset of same-day studies acquired over a subsequent 7-month period. Accuracy of the prediction tool was assessed by calculating the mean absolute percentage error (MAPE). RESULTS: Of 643 studies performed, the scans of 342 participants (median age 30.4 years, 318 female) were included in the training dataset, the analysis of which yielded a significant regression equation (F(1,340) = 1057.3, p < 0.0001), with an adjusted R2 of 0.756 and MSE of 0.001089. A prediction tool designed for routine clinical use was developed for predicting final P/V ratio. Of an additional 285 studies, 198 were included in the second (validation) dataset (median age 29.7 years, 188 female). The Excel-based tool was shown to be 91% accurate (MAPE: 9%) in predicting P/V ratio. CONCLUSION: The relationship between the ratio of simultaneously acquired counts in adjacent energy windows on V SPECT and perfusion count rate after administration of a known activity of [99mTc]Tc-MAA can be linearly approximated. A predictive tool based on this work may assist in optimising the dose and timing of [99mTc]Tc-MAA administration in same-day studies to the benefit of patients and workflows.

2.
Ocul Immunol Inflamm ; 29(3): 530-536, 2021 Apr 03.
Article in English | MEDLINE | ID: mdl-31743044

ABSTRACT

Purpose: To determine the utility of fluorine-18 fluorodeoxyglucose Positron Emission Tomography Computed Tomography (FDG PET/CT) in patients with suspected ocular sarcoidosis (OS) or intraocular tuberculosis (IOTB) in a resource-constrained, TB endemic area.Methods: Independent review of the FDG PET/CTs, Computed Tomography (CT) scans and chest radiographs (CXRs) of patients with suspected OS or IOTB and inconclusive conventional workup.Results: Twenty-nine PET/CTs and CXRs were reviewed, with 38% of PET/CTs and CTs demonstrating evidence of TB or sarcoidosis, compared to 21% of CXRs. The sensitivity, specificity, positive and negative predictive values for PET/CT and CT were similar - 85.7%, 95.5%, 85.7% and 95.5% for OS, and 33.3%, 100%, 100% and 68% for IOTB respectively and for CXR, 57.1%, 100%, 100% and 88% for OS, and 16.7%, 100%, 100% and 63% for IOTB.Conclusion: PET/CT added no significant additional benefit over Chest CT in patients with suspected OS or IOTB.


Subject(s)
Eye Diseases/diagnostic imaging , Fluorodeoxyglucose F18/administration & dosage , Positron Emission Tomography Computed Tomography , Radiopharmaceuticals/administration & dosage , Sarcoidosis/diagnostic imaging , Tuberculosis, Pulmonary/diagnostic imaging , Adult , Aged , False Positive Reactions , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Radiography, Thoracic , Retrospective Studies , Sensitivity and Specificity , Tuberculin Test , Young Adult
3.
S Afr Med J ; 110(3): 229-234, 2020 Feb 26.
Article in English | MEDLINE | ID: mdl-32657701

ABSTRACT

BACKGROUND: The Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations are two commonly used formulae to estimate glomerular filtration rate (GFR) in adults. The CKD-EPI equation is recommended in current international and local guidelines for the diagnosis and management of chronic kidney disease (CKD), unless an alternative equation has been shown to have superior accuracy. Validation and comparison of the equations in local populations are therefore required. Previous studies have reported on the accuracy of these prediction equations in black South Africans and those of Indian ancestry. OBJECTIVES: To evaluate the MDRD and CKD-EPI equations in South African (SA) adults of mixed ancestry. METHODS: In all participants, GFR was measured (mGFR) from plasma clearance of 99mTc-diethylenetetraaminepenta-acetic acid (99mTc-DTPA), using a standardised technique. Serum creatinine assays were isotope dilution mass spectrometry traceable. GFR was estimated (eGFR) using the MDRD and CKD-EPI equations, with and without the black ethnicity factor. The agreement, bias, precision and accuracy of each equation was determined. RESULTS: Eighty adults were included (30 male, median age 39 years, median GFR 59 mL/min/1.73 m2). Sixty-eight had a diagnosis of CKD, 10 were potential kidney donors, and 2 were healthy volunteers. Both equations, without the black ethnicity factor, had good agreement with measured GFR. The equations tended to overestimate GFR, with bias of 1.6 and 7.9 mL/min/1.73 m2 for the MDRD and CKD-EPI equations, respectively. The interquartile ranges of the differences were 15.9 and 20.2 mL/min/1.73 m2, and as a measure of accuracy, the percentages of estimates that fell within 30% of the mGFR (P30) were 80% and 72.5% (p=0.18). For identification of individuals with a GFR <60 mL/min/1.73 m2, the sensitivity of MDRD eGFR was 97.3% and that of CKD-EPI eGFR was 97.1%. CONCLUSIONS: The MDRD and CKD-EPI equations have shown satisfactory and comparable performance in this SA mixed-ancestry adult population, with the MDRD equation marginally less biased than the CKD-EPI.


Subject(s)
Glomerular Filtration Rate , Adolescent , Adult , Aged , Black People , Female , Humans , Male , Middle Aged , Renal Insufficiency, Chronic/epidemiology , South Africa , Young Adult
4.
S Afr J Surg ; 57(3): 44-49, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31392864

ABSTRACT

BACKGROUND: Accurate pre-operative staging and correct surgical selection of patients with malignant melanoma reduces unnecessary morbidity and mortality, improves distant control and may improve survival. 18F-fluorodeoxyglucose Positron Emission Tomography Computed Tomography (18F-FDG PET-CT) has been shown to be useful in exclusion of metastatic sites and aids in surgical planning in stage III and potentially resectable stage IV disease. The primary objective of the study was to determine whether the use of PET-CT alters the initial staging and management of patients with advanced and recurrent melanoma. METHOD: Retrospective analysis of clinical records of patients with malignant melanoma referred for staging PET-CT over a three-year period at our institution was performed. Pre- and post-PET-CT stage was recorded and a descriptive analysis was done to determine whether PET-CT resulted in a change in stage grouping and whether this change effected a change in clinical management. RESULTS: A change in stage grouping occurred in 21/39 (53.8%) of patients, 76.2% of which were up-staged and 23.8% down staged. On analysis of stage III/IV and recurrent melanoma, a change in stage occurred in 90% of stage III, 50% of stage IV and 50% of recurrent melanoma patients. This effected a change in management in 86.7% of patients with stage III, IV and recurrent melanoma collectively. CONCLUSION: PET-CT is a useful tool in the staging and subsequent management of melanoma. Its utility is pronounced in advanced and recurrent melanoma.


Subject(s)
Melanoma/diagnostic imaging , Melanoma/secondary , Neoplasm Recurrence, Local/diagnostic imaging , Positron Emission Tomography Computed Tomography , Skin Neoplasms/diagnostic imaging , Skin Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Female , Fluorodeoxyglucose F18 , Humans , Male , Melanoma/therapy , Middle Aged , Neoplasm Staging , Radiopharmaceuticals , Retrospective Studies , Skin Neoplasms/therapy , Young Adult
5.
Sci Justice ; 45(2): 93-6, 2005.
Article in English | MEDLINE | ID: mdl-16080322

ABSTRACT

Four sets of acrylic fibre samples were obtained from a company that dyes fabrics for the fashion industry. Between seven and ten different batches of fibres constituted each set. Comparison microscopy, visible and UV range microspectrophotometry and thin layer chromatography (TLC) were used to compare the dyes on each batch of fibres within the sets. Only one of the four sets exhibited variation within the batches. The differences were seen when both microscopical and analytical techniques were used. In addition, two further sets of samples had been obtained from a company that produces carpets for the car industry. The first set consisted of 26 batches of acid dyed orange nylon fibres. The second consisted of 21 batches of acid dyed mustard coloured nylon and direct dyed brown viscose fibres blended together. When the first set was viewed under UV light one batch had more pale orange fibres present and they fluoresced more brightly than the other fibres. This could be due to the blending with a different dye batch of fibre or due to poor dye uptake--the latter being more likely. When tested using visible and UV range microspectrophotometry and TLC, further dye batch variation was not detected. The second set was examined after separating the nylon and viscose fibres from each other. The nylon fibres were indistinguishable when a range of microscopical and analytical techniques were employed; however, the viscose fibres showed dye batch variation when TLC was used.

SELECTION OF CITATIONS
SEARCH DETAIL
...