Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Sports Med ; 52(6): 1505-1513, 2024 May.
Article in English | MEDLINE | ID: mdl-38551132

ABSTRACT

BACKGROUND: There is little evidence of the biomechanical performance of medial collateral ligament (MCL) reconstructions for restoring stability to the MCL-deficient knee regarding valgus, external rotation (ER), and anteromedial rotatory instability (AMRI). HYPOTHESIS: A short isometric reconstruction will better restore stability than a longer superficial MCL (sMCL) reconstruction, and an additional deep MCL (dMCL) graft will better control ER and AMRI than single-strand reconstructions. STUDY DESIGN: Controlled laboratory study. METHODS: Nine cadaveric human knees were tested in a kinematics rig that allowed tibial loading while the knee was flexed-extended 0° to 100°. Optical markers were placed on the femur and tibia and displacements were measured using a stereo camera system. The knee was tested intact, and then after MCL (sMCL + dMCL) transection, and loaded in anterior tibial translation (ATT), ER, varus-valgus, and combined ATT + ER (AMRI loading). Five different isometric MCL reconstructions were tested: isolated long sMCL, a short construct, each with and without dMCL addition, and isolated dMCL reconstruction, using an 8 mm-wide synthetic graft. RESULTS: MCL deficiency caused an increase in ER of 4° at 0° of flexion (P = .271) up to 14° at 100° of flexion (P = .002), and valgus laxity increased by 5° to 8° between 0° and 100° of flexion (P < .024 at 0°-90°). ATT did not increase significantly in isolated MCL deficiency (P > .999). All 5 reconstructions restored native stability across the arc of flexion apart from the isolated long sMCL, which demonstrated residual ER instability (P≤ .047 vs other reconstructions). CONCLUSION: All tested techniques apart from the isolated long sMCL graft are satisfactory in the context of restoring the valgus, ER, and AMRI stability to the MCL-deficient knee in a cadaveric model. CLINICAL RELEVANCE: Contemporary MCL reconstruction techniques fail to control ER and therefore AMRI as they use a long sMCL graft and do not address the dMCL. This study compares 5 MCL reconstruction techniques. Both long and short isometric constructs other than the long sMCL achieved native stability in valgus and ER/AMRI. Double-strand reconstructions (sMCL + dMCL) tended to provide more stability. This study shows which reconstructions demonstrate the best biomechanical performance, informs surgical reconstruction techniques for AMRI, and questions the efficacy of current popular techniques.


Subject(s)
Cadaver , Joint Instability , Medial Collateral Ligament, Knee , Humans , Biomechanical Phenomena , Medial Collateral Ligament, Knee/surgery , Joint Instability/surgery , Joint Instability/physiopathology , Male , Aged , Middle Aged , Plastic Surgery Procedures/methods , Female , Knee Joint/surgery , Knee Joint/physiology , Rotation
2.
Am J Sports Med ; 51(5): 1136-1145, 2023 04.
Article in English | MEDLINE | ID: mdl-36917838

ABSTRACT

BACKGROUND: Injuries to the anterior cruciate ligament (ACL), Kaplan fibers (KFs), anterolateral capsule/ligament (C/ALL), and lateral meniscus posterior root (LMPR) have been separately linked to anterolateral instability. PURPOSE: To investigate the contributions of the ACL, KFs, C/ALL, and LMPR to knee stability and to measure instabilities resulting from their injury. STUDY DESIGN: Controlled laboratory study. METHODS: Ten fresh-frozen human knees were tested robotically to determine restraints of knee laxity at 0° to 90° of flexion. An 88-N anterior-posterior force (anterior and posterior tibial translation), 5-N·m internal-external rotation, and 8-N·m valgus-varus torque were imposed and intact kinematics recorded. The kinematics were replayed after sequentially cutting the structures (order varied) to calculate their contributions to stability. Another 10 knees were tested in a kinematics rig with optical tracking to measure instabilities after sequentially cutting the structures across 0° to 100° of flexion. One- and 2-way repeated-measures analyses of variance with Bonferroni correction were used to find significance (P < .05) for the robotic and kinematics tests. RESULTS: The ACL was the primary restraint for anterior tibial translation; other structures were insignificant (<10% contribution). The KFs and C/ALL resisted internal rotation, reaching 44% ± 23% (mean ± SD; P < .01) and 14% ± 13% (P < .05) at 90°. The LMPR resisted valgus but not internal rotation. Anterior tibial translation increased after ACL transection (P < .001) and after cutting the lateral structures from 70° to 100° (P < .05). Pivot-shift loading increased anterolateral rotational instability after ACL transection from 0° to 40° (P < .05) and further after cutting the lateral structures from 0° to 100° (P < .01). CONCLUSION: The anterolateral complex acts as a functional unit to provide rotatory stability. The ACL is the primary stabilizer for anterior tibial translation. The KFs are the most important internal rotation restraint >30° of flexion. Combined KFs + C/ALL injury substantially increased anterolateral rotational instability while isolated injury of either did not. LMPR deficiency did not cause significant instability with the ACL intact. CLINICAL RELEVANCE: This study is a comprehensive biomechanical sectioning investigation of the knee stability contributions of the ACL, anterolateral complex, and LMPR and the instability after their transection. The ACL is significant in controlling internal rotation only in extension. In flexion, the KFs are dominant, synergistic with the C/ALL. LMPR tear has an insignificant effect with the ACL intact.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Joint Instability , Humans , Anterior Cruciate Ligament/surgery , Menisci, Tibial , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/methods , Knee Joint/surgery , Range of Motion, Articular , Joint Instability/surgery , Biomechanical Phenomena , Cadaver
3.
Front Med Technol ; 4: 1004976, 2022.
Article in English | MEDLINE | ID: mdl-36530549

ABSTRACT

Treating open fractures in long bones can be challenging and if not performed properly can lead to poor outcomes such as mal/non-union, deformity, and amputation. One of the most common methods of treating these fracture types is temporary external fixation followed by definitive fixation. The shortage of high-quality affordable external fixators is a long-recognised need, particularly in Low- and Middle-Income Countries (LMICs). This research aimed to develop a low-cost device that can be manufactured locally to international standards. This can provide surge capacity for conflict zones or in response to unpredictable incidents and situations. The fixator presented here and developed by us, the Imperial external fixator, was tested on femur and tibia specimens under 100 cycles of 100 N compression-tension and the results were compared with those of the Stryker Hoffmann 3 frame. The Imperial device was stiffer than the Stryker Hoffmann 3 with a lower median interfragmentary motion (of 0.94 vs. 1.48 mm). The low-cost, easy to use, relatively lightweight, and easy to manufacture (since minimum skillset and basic workshop equipment and materials are needed) device can address a critical shortage and need in LMICs particularly in conflict-affected regions with unpredictable demand and supply. The device is currently being piloted in three countries for road traffic accidents, gunshot wounds and other conflict trauma-including blast cohorts.

4.
Am J Sports Med ; 50(7): 1832-1842, 2022 06.
Article in English | MEDLINE | ID: mdl-35503457

ABSTRACT

BACKGROUND: There are many descriptions of medial collateral ligament (MCL) reconstruction, but they may not reproduce the anatomic structures and there is little evidence of their biomechanical performance. PURPOSE: To investigate the ability of "anatomic" MCL reconstruction to restore native stability after grade III MCL plus posteromedial capsule/posterior oblique ligament injuries in vitro. STUDY DESIGN: Controlled laboratory study. METHODS: Twelve cadaveric knees were mounted in a kinematic testing rig to impose tibial displacing loads while the knee was flexed-extended: 88-N anteroposterior translation, 5-N·m internal-external rotation, 8-N·m valgus-varus, and combined anterior translation plus external rotation (anteromedial rotatory instability). Joint motion was measured via optical trackers with the knee intact; after superficial MCL (sMCL), deep MCL (dMCL), and posterior oblique ligament transection; and then after MCL double- and triple-strand reconstructions. Double strands reproduced the sMCL and posterior oblique ligament and triple-strands the sMCL, dMCL, and posterior oblique ligament. The sMCL was placed 5 mm posterior to the epicondyle in the double-strand technique and at the epicondyle in the triple-strand technique. Kinematic changes were examined by repeated measures 2-way analysis of variance with posttesting. RESULTS: Transection of the sMCL, dMCL, and posterior oblique ligament increased valgus rotation (5° mean) and external rotation (9° mean). The double-strand reconstruction controlled valgus in extension but allowed 5° excess valgus in flexion and did not restore external rotation (7° excess). The triple-strand reconstruction restored both external rotation and valgus throughout flexion. CONCLUSION: In a cadaveric model, a triple-strand reconstruction including a dMCL graft restored native external rotation, while a double-strand reconstruction without a dMCL graft did not. A reconstruction with the sMCL graft placed isometrically on the medial epicondyle restored valgus rotation across the arc of knee flexion, whereas a reconstruction with a more posteriorly placed sMCL graft slackened with knee flexion. CLINICAL RELEVANCE: An MCL injury may rupture the anteromedial capsule and dMCL, causing anteromedial rotatory instability. Persistent MCL instability increases the likelihood of ACL graft failure after combined injury. A reconstruction with an anteromedial dMCL graft restored native external rotation, which may help to unload/protect an ACL graft. It is important to locate the sMCL graft isometrically at the femoral epicondyle to restore valgus across flexion.


Subject(s)
Joint Instability , Medial Collateral Ligament, Knee , Biomechanical Phenomena , Cadaver , Humans , Joint Instability/surgery , Knee Joint/surgery , Ligaments, Articular/surgery , Medial Collateral Ligament, Knee/surgery , Range of Motion, Articular
5.
Am J Sports Med ; 50(7): 1823-1831, 2022 06.
Article in English | MEDLINE | ID: mdl-35511430

ABSTRACT

BACKGROUND: Although a medial collateral ligament (MCL) injury is associated with anteromedial rotatory instability (AMRI) and often with an anterior cruciate ligament (ACL) injury, there has been little work to develop anteromedial (AM) reconstruction to address this laxity. PURPOSE: To measure the ability of a novel "anatomic" AM reconstruction technique to restore native knee laxity for isolated AM insufficiency and combined AM plus posteromedial insufficiency. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 12 cadaveric knees were mounted in a kinematic testing rig that allowed the tibia to be loaded while the knee flexed-extended 0° to 100° with 88-N anteroposterior translation, 5-N·m internal rotation-external rotation (ER), 8-N·m valgus, and combined anterior translation plus ER to simulate AMRI. Joint motion was measured using optical trackers with the knee intact, after superficial MCL (sMCL) and deep MCL (dMCL) transection, and after AM reconstruction of the sMCL and dMCL with semitendinosus autografts. The posteromedial capsule (PMC)/posterior oblique ligament (POL) was then transected to induce a grade 3 medial injury, and kinematic measurements were repeated afterward and again after removing the grafts. Laxity changes were examined using repeated-measures analysis of variance and post-testing. RESULTS: sMCL and dMCL deficiency increased valgus, ER, and AMRI laxities. These laxities did not differ from native values after AM reconstruction. Additional PMC/POL deficiency did not increase these laxities significantly but did increase internal rotation laxity near knee extension; this was not controlled by AM reconstruction. CONCLUSION: AM reconstruction eliminated AMRI after transection of the dMCL and sMCL, and also eliminated AMRI after additional PMC/POL transection. CLINICAL RELEVANCE: Many MCL injuries occur in combination with ACL injuries, causing AMRI. These injuries may rupture the AM capsule and dMCL. Unaddressed MCL deficiency leads to an increased ACL reconstruction failure rate. A dMCL construct oriented anterodistally across the medial joint line, along with an sMCL graft, can restore native knee ER laxity. PMC/POL lesions did not contribute to AMRI.


Subject(s)
Anterior Cruciate Ligament Injuries , Collateral Ligaments , Joint Instability , Medial Collateral Ligament, Knee , Anterior Cruciate Ligament Injuries/surgery , Biomechanical Phenomena , Cadaver , Humans , Joint Instability/etiology , Joint Instability/surgery , Knee Joint/surgery , Medial Collateral Ligament, Knee/surgery , Range of Motion, Articular , Torque
SELECTION OF CITATIONS
SEARCH DETAIL
...