Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc Diabetol ; 19(1): 165, 2020 10 02.
Article in English | MEDLINE | ID: mdl-33008407

ABSTRACT

BACKGROUND: Several studies compared everolimus-eluting bioresorbable scaffolds (EE-BRS) with everolimus-eluting stents (EES), but only few assessed these devices in patients with diabetes mellitus. AIM: To evaluate the safety and efficacy outcomes of all-comer patients with diabetes mellitus up to 2 years after treatment with EE-BRS or EES. METHODS: We performed a post hoc pooled analysis of patient-level data in diabetic patients who were treated with EE-BRS or EES in 3 prospective clinical trials: The ABSORB DM Benelux Study (NTR5447), TWENTE (NTR1256/NCT01066650) and DUTCH PEERS (NTR2413/NCT01331707). Primary endpoint of the analysis was target lesion failure (TLF): a composite of cardiac death, target vessel myocardial infarction or clinically driven target lesion revascularization. Secondary endpoints included major adverse cardiac events (MACE): a composite of all-cause death, any myocardial infarction or clinically driven target vessel revascularization, as well as definite or probable device thrombosis (ST). RESULTS: A total of 499 diabetic patients were assessed, of whom 150 received EE-BRS and 249 received EES. Total available follow-up was 222.6 patient years (PY) in the EE-BRS and 464.9 PY in the EES group. The adverse events rates were similar in both treatment groups for TLF (7.2 vs. 5.2 events per 100 PY, p = 0.39; adjusted hazard ratio (HR) = 1.48 (95% confidence interval (CI): 0.77-2.87), p = 0.24), MACE (9.1 vs. 8.3 per 100 PY, p = 0.83; adjusted HR = 1.23 (95% CI: 0.70-2.17), p = 0.47), and ST (0.9 vs. 0.6 per 100 PY, p > 0.99). CONCLUSION: In this patient-level pooled analysis of patients with diabetes mellitus from 3 clinical trials, EE-BRS showed clinical outcomes that were quite similar to EES.


Subject(s)
Absorbable Implants , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Diabetes Mellitus , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Aged , Cardiovascular Agents/adverse effects , Clinical Trials as Topic , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Diabetes Mellitus/diagnosis , Diabetes Mellitus/mortality , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
2.
Neth Heart J ; 27(11): 541-549, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31197750

ABSTRACT

BACKGROUND: Diabetes mellitus (DM) patients show higher rates of repeat revascularisation even in the era of modern drug-eluting stents (DES). The concept of bioresorbable scaffolds is becoming captivating, as it might allow for repeat interventions, prolonging the time span during which patients can be treated by percutaneous coronary intervention (PCI). AIMS: We intend to evaluate the short- and long-term safety and efficacy of Absorb bioresorbable vascular scaffolds (Absorb BVS) in the treatment of coronary artery disease (CAD) in DM patients for any indication. METHODS: The ABSORB DM Benelux is an international prospective study in DM patients who have undergone PCI with ≥1 Absorb BVS. Major adverse cardiac events (MACE) at 1 year was the primary endpoint, defined as a composite of all-cause death, any myocardial infarction (MI) and ischaemia-driven target vessel revascularisation (TVR). Secondary endpoints were target lesion failure (TLF) and definite or probable scaffold thrombosis (ScT). RESULTS: Between April 2015 and March 2017, 150 DM patients and 188 non-complex lesions were treated. Device implantation was successful in 100%. MACE occurred in 14 (9.5%) patients, with all-cause death occurring in 4 (2.7%), any MI in 6 (4.1%) and ischaemia-driven TVR in 7 (4.8%) respectively. TLF was reported in 11 (7.5%). Definite and probable ScT was observed in 2 (1.4%). CONCLUSION: Absorb BVS for treatment of anatomically low-risk patients with DM show acceptable safety and efficacy outcomes at 1 year. If these promising results are confirmed after a longer follow-up period, new-generation bioresorbable scaffolds combined with refinement of implantation techniques might open new horizons for CAD treatment in DM patients.

3.
Cardiovasc Diabetol ; 18(1): 25, 2019 03 09.
Article in English | MEDLINE | ID: mdl-30851731

ABSTRACT

BACKGROUND: Percutaneous coronary intervention (PCI) in patients with diabetes mellitus (DM) remains challenging even with modern drug-eluting stents (DES) due to high rates of repeat revascularization. Everolimus-eluting bioresorbable scaffolds (EE-BRS) might allow for repeat intervention prolonging the time interval of percutaneous treatment options. METHODS: The ABSORB DM Benelux Study is a dedicated prospective, international study to evaluate the midterm safety and efficacy of EE-BRS in DM patients. All DM patients that received ≥ 1 EE-BRS for any indication were enrolled and prospectively followed. Study endpoints were major adverse cardiac events (MACE): a composite of all-cause death, any myocardial infarction (MI) and ischemic-driven target vessel revascularization (TVR); target lesion failure (TLF): a composite of cardiac death (CD), target vessel MI, and ischemic-driven target lesion revascularization (TLR), as well as definite or probable scaffold thrombosis (ScT). RESULTS: Between April 2015 till March 2017, 150 DM patients and 188 lesions were treated and followed up to 3 years. Device implantation success was 100%. MACE occurred in 15.2% (event rate of 8.8 per 100 PY). TLF was reported in 11.7% (7.0 events per 100 PY). CD, target vessel MI, ischemic-driven TLR occurred in 3.4%, 3.6% and 5.5% respectively, while ScT was observed in 1.4%. There were no occurrences of late or very late ScT. CONCLUSION: EE-BRS treatment in DM patients shows comparable midterm safety and efficacy outcomes when historically compared with modern DES. New-generation EE-BRS might offer an attractive alternative to metallic DES in treatment of fast progressing atherosclerosis population as in DM patients. Trial registration NTR5447. Registered 05 October 2015, retrospectively registered.


Subject(s)
Absorbable Implants , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Artery Disease/surgery , Diabetes Mellitus/epidemiology , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Aged , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/epidemiology , Diabetes Mellitus/diagnosis , Diabetes Mellitus/mortality , Europe/epidemiology , Everolimus/adverse effects , Female , Follow-Up Studies , Humans , Male , Middle Aged , Myocardial Infarction/epidemiology , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prospective Studies , Prosthesis Design , Registries , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...