Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
Maxillofac Plast Reconstr Surg ; 42(1): 31, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32995343

ABSTRACT

BACKGROUND: Fibrous dysplasia (FD) is a rare, sporadic, and benign congenital condition in which normal cancellous bone is replaced by fibro-osseous tissue with immature osteogenesis. FD localized in the cranial and facial bones is called craniofacial fibrous dysplasia (CFD). Cystic degeneration in CFD cases is rare; cystic degeneration appearing in both the maxilla and the mandible FD lesion is even rarer. The aim of this article was to report a case of fibrous dysplasia of the mandible and maxilla complicated by nonspecific cystic degeneration. CASE PRESENTATION: A 30-year-old woman presented with a rare case of non-specific cystic degeneration in a mandible and maxilla FD lesion that occurred 11 years after surgery. She was diagnosed with polyostotic CFD and underwent maxillary and mandibular bone contouring. Cyst enucleation under general anesthesia was performed in the mandibular region due to pain and discomfort. CONCLUSIONS: In cases involving non-aggressive and non-invasive FD cystic degeneration in focal areas, conservative treatment is recommended. However, if cystic degeneration of FD develops rapidly and causes discomfort, pain, or dysfunction, surgical treatment should be considered.

2.
Article in English | MEDLINE | ID: mdl-31508357

ABSTRACT

[This corrects the article on p. 51 in vol. 45, PMID: 31106133.].

3.
J Korean Assoc Oral Maxillofac Surg ; 45(2): 51-67, 2019 Apr.
Article in English | MEDLINE | ID: mdl-31106133

ABSTRACT

As dental implant surgery and bone grafts were widely operated in Korean dentist, many bone substitutes are commercially available, currently. For commercially used in Korea, all bone substitutes are firstly evaluated by the Ministry of Health and Welfare (MOHW) for safety and efficacy of the product. After being priced, classified, and registration by the Health Insurance Review and Assessment Service (HIRA), the post-application management is obligatory for the manufacturer (or representative importer) to receive a certificate of Good Manufacturing Practice by Ministry of Food and Drug Safety. Currently, bone substitutes are broadly classified into C group (bone union and fracture fixation), T group (human tissue), L group (general and dental material) and non-insurance material group in MOHW notification No. 2018-248. Among them, bone substitutes classified as dental materials (L7) are divided as xenograft and alloplastic bone graft. The purpose of this paper is to analyze alloplastic bone substitutes of 37 products in MOHW notification No. 2018-248 and to evaluate the reference level based on the ISI Web of Knowledge, PubMed, EMBASE (1980-2019), Cochrane Database, and Google Scholar using the criteria of registered or trademarked product name.

4.
Maxillofac Plast Reconstr Surg ; 41(1): 19, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31106163

ABSTRACT

BACKGROUND: The submucous cleft palate (SMCP) is a type of cleft palate that may result in velopharyngeal insufficiency (VPI). Palate muscles completely separate oral and nasal cavities by closing off the velopharynx during functional processes such as speech or swallow. Also, hypernasality may arise from anatomical or neurological abnormalities in these functions. Treatments of this issue involve a combination of surgical intervention, speech aid, and speech therapy. This case report demonstrates successfully treated VPI resulted from SMCP without any surgical intervention but solely with speech aid appliance and speech therapy. CASE PRESENTATION: A 13-year-old female patient with a speech disorder from velopharyngeal insufficiency that was caused by a submucous cleft palate visited to our OMFS clinic. In the intraoral examination, the patient had a short soft palate and bifid uvula. And the muscles in the palate did not contract properly during oral speech. She had no surgical history such as primary palatoplasty or pharyngoplasty except for tonsillectomy. And there were no other medical histories. Objective speech assessment using nasometer was performed. We diagnosed that the patient had a SMCP. The patient has shown a decrease in speech intelligibility, which resulted from hypernasality. We decided to treat the patient with speech aid (palatal lift) along with speech therapy. During the 7-month treatment, hypernasality measured by a nasometer decreased and speech intelligibility became normal. CONCLUSIONS: Surgery remains the first treatment option for patients with velopharyngeal insufficiencies from submucous cleft palates. However, there were few reports about objective speech evaluation pre- or post-operation. Moreover, there has been no report of non-surgical treatment in the recent studies. From this perspective, this report of objective improvement of speech intelligibility of VPI patient with SMCP by non-surgical treatment has a significant meaning. Speech aid can be considered as one of treatment options for management of SMCP.

5.
Rev Sci Instrum ; 87(2): 02A728, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931946

ABSTRACT

The injector for the main driver linear accelerator of the Rare Isotope Science Project in Korea, has been developed to allow heavy ions up to uranium to be delivered to the inflight fragmentation system. The critical components of the injector are the superconducting electron cyclotron resonance (ECR) ion sources, the radio frequency quadrupole (RFQ), and matching systems for low and medium energy beams. We have built superconducting magnets for the ECR ion source, and a prototype with one segment of the RFQ structure, with the aim of developing a design that can satisfy our specifications, demonstrate stable operation, and prove results to compare the design simulation.

6.
Rev Sci Instrum ; 87(2): 02A734, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931952

ABSTRACT

RAON, a 28 GHz electron cyclotron resonance ion source (ECR IS), was designed and tested as a Rare Isotope Science Project. It is expected that RAON would provide not only rare-isotope beams but also stable heavy ions ranging from protons to uranium. In order to obtain the steady heavy-ion beam required for ECR IS, we must use a 28 GHz microwave source as well as a high magnetic field. A superconducting magnet using a NbTi wire was designed and manufactured for producing the ECR IS and a test was conducted. In this paper, the design and fabrication of the superconducting magnet for the ECR IS are presented. Experimental results show that the quench current increases whenever quenching occurs, but it has not yet reached the designed current. The experiment is expected to reveal the ideal conditions required to reach the designed current.


Subject(s)
Cyclotrons , Electrons , Niobium , Superconductivity , Titanium , Ions
7.
Rev Sci Instrum ; 87(2): 02A735, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931953

ABSTRACT

A 28 GHz electron cyclotron resonance (ECR) ion source is being developed for use as an injector for the superconducting linear accelerator of the Rare Isotope Science Project. Beam extraction from the ECR ion source has been simulated using the KOBRA3-INP software. The simulation software can calculate charged particle trajectories in three dimensional complex magnetic field structures, which in this case are formed by the arrangement of five superconducting magnets. In this study, the beam emittance is simulated to understand the effects of plasma potential, mass-to-charge ratio, and spatial distribution. The results of these simulations and their comparison to experimental results are presented in this paper.

8.
Rev Sci Instrum ; 87(2): 02B911, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26932083

ABSTRACT

RAON (Rare isotope Accelerator Of Newness) heavy ion accelerator of the rare isotope science project in Daejeon, Korea, has been designed to accelerate multiple-charge-state beams to be used for various science programs. In the RAON accelerator, the rare isotope beams which are generated by an isotope separation on-line system with a wide range of nuclei and charges will be transported through the post Low Energy Beam Transport (LEBT) section to the Radio Frequency Quadrupole (RFQ). In order to transport many kinds of rare isotope beams stably to the RFQ, the post LEBT should be devised to satisfy the requirement of the RFQ at the end of post LEBT, simultaneously with the twiss parameters small. We will present the recent lattice design of the post LEBT in the RAON accelerator and the results of the beam dynamics simulations from it. In addition, the error analysis and correction in the post LEBT will be also described.

9.
Rev Sci Instrum ; 87(2): 02B916, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26932088

ABSTRACT

A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

10.
J Nanosci Nanotechnol ; 12(2): 966-70, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22629880

ABSTRACT

We investigated the critical conditions to realize reliable and nano-engineered templates for surface-plasmon enhanced Raman scattering (SERS). Ultra-sensitive SERSs of thymine oligonucleotides were successfully realized on the template of Au nanoparticle arrays which were prepared by the combination of electron-beam lithography and post-chemical modification techniques. Drastic enhancement of Raman signal from the thymine oligonucleotides was only observed on the optimized templates, where the tuning of the plasmon resonance condition and the formation of the hot spots were both critical. Our results suggest that the artificial generation of reproducible and controlled hot spots can be achieved by our approach.

11.
Rev Sci Instrum ; 83(2): 02B914, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380346

ABSTRACT

A 2.45 GHz microwave ion source for ion implanters has many good properties for industrial application, such as easy maintenance and long lifetime, and it should be compact for budget and space. But, it has a dc current supply for the solenoid and a rf generator for plasma generation. Usually, they are located on high voltage platform because they are electrically connected with beam extraction power supply. Using permanent magnet solenoid and multi-layer dc break, high voltage deck and high voltage isolation transformer can be eliminated, and the dose rate on targets can be controlled by pulse duty control with semiconductor high voltage switch. Because the beam optics does not change, beam transfer components, such as focusing elements and beam shutter, can be eliminated. It has shown the good performances in budget and space for industrial applications of ion beams.

13.
Rev Sci Instrum ; 79(2 Pt 2): 02C704, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18315257

ABSTRACT

A fast timing system has been developed to control transistor transistor logic (TTL) trigger signals which are used to extract the pulsed proton beam from an ion source with the precision of less than submicro seconds. The system has been designed to set a delay and duty of the pulses, respectively, and prohibit the beam pulse by an external interlock signal. The system is based on VME which is composed of VME CPU and fast I/O boards with fan-out modules. The software of the system has been developed by the record/device supports and channel access in the core of the EPICS environments. In the paper, we describe software configurations and hardware drivers.

14.
Rev Sci Instrum ; 79(2 Pt 2): 02C718, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18315271

ABSTRACT

A proton beam irradiation system for the application of the MeV class proton beam, such as an implantation for a power semiconductor device and a smart-cut technology for a semiconductor production process, has been developed. This system consists of a negative ion source, an Einzel lens for a low energy beam transport, accelerating tubes, a gas stripper, a Cockroft-Walton high voltage power supply with 1 MV, a vacuum pumping system, and a high pressure insulating gas system. The negative hydrogen ion source is based on TRIUMF's design. Following the tandem accelerator, a pair of magnets is installed for raster scanning of the MeV proton beam to obtain a uniform irradiation pattern on the target. The system is 7 m long from the ion source to the target and is optimized for the proton beam irradiation. The details of the system development will be described.

SELECTION OF CITATIONS
SEARCH DETAIL
...