J Chromatogr Sci ; 51(4): 297-301, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23377654

ABSTRACT

A rapid, accurate and sensitive liquid chromatography-tandem mass spectrometry method has been developed for the determination of a quaternary nitrogen muscle relaxant, rocuronium, in human blood. The procedure involves protein precipitation with chloroform and trichloroacetic acid, and purification using methanol. The chromatography was performed using a phenyl-hexyl column (150 × 2.0 mm i.d., 3 µm; Phenomenex) with a mobile phase consisting of 5 mM ammonium formate (pH 3.0) and acetonitrile. Multiple reaction monitoring was used for quantification. The assay was linear over a concentration range of 4-500 ng/mL for rocuronium with R(2) ≥ 0.998. The recoveries for this compound ranged from 96.0 to 109.1%. The intra-day and inter-day precision was less than 10.5% and the accuracy ranged from 106.6 to 114.9%. The validated method was applied to quantify the content of rocuronium in blood and a variety of tissues of a victim suspected of overdose. In conclusion, the method was successfully applied for the analysis of rocuronium in biological samples for forensic toxicology.


Subject(s)
Androstanols/analysis , Androstanols/blood , Chromatography, High Pressure Liquid/methods , Tandem Mass Spectrometry/methods , Adult , Androstanols/pharmacokinetics , Female , Humans , Limit of Detection , Reproducibility of Results , Rocuronium , Spectrometry, Mass, Electrospray Ionization/methods , Tissue Distribution
2.
Forensic Sci Int ; 217(1-3): 76-80, 2012 Apr 10.
Article in English | MEDLINE | ID: mdl-22019394

ABSTRACT

A sensitive analytical method was developed for the quantitative determination of tetrodotoxin (TTX), a powerful sodium channel blocker, in human postmortem whole blood. The sample mixture was cleaned up using cation exchange SPE catridge after protein precipitation by methanol and then separated on a PC-HILIC (phosphorylcholine hydrophilic interaction liquid chromatography) column (150 mm × 2.0mm i.d., 5 µm) using a isocratic elution of 1% acetic acid and acetonitrile. The identification of TTX was performed on tandem mass spectrometry with electrospray ionization interface in positive ion mode. The retention time of voglibose (internal standard) and TTX was 5.1 and 6.0 min, respectively. TTX and internal standard (voglibose) were monitored and quantitated using the ion transitions: the respective precursor to product ion combinations, m/z 320/302 for TTX and m/z 268/92 for voglibose in the multiple reaction monitoring (MRM) mode. The recovery of TTX and voglibose was 61.4% and 62.8%, respectively and the good accuracy (97.7-103.9%), linearity (2-1200 ng/mL) and reproducibility were shown in this method. The limit of detection and limit of quantification were 0.32 ng/mL and 1.08 ng/mL, respectively. This method was applied in the case of three fishermen who were poisoned (including one death) by unknown fish on their boat in October 2010. In this case, the levels of TTX were 27.2, 30.0 and 29.7 ng/mL in heart blood, peripheral blood and serum of a victim, were 3.1 and 12.1 ng/mL in peripheral blood and 3.9 and 12.8 ng/mL in serum of two survivors, respectively.


Subject(s)
Chromatography, Liquid/methods , Poisons/blood , Spectrometry, Mass, Electrospray Ionization/methods , Tetrodotoxin/blood , Animals , Fishes, Poisonous , Forensic Toxicology , Humans , Limit of Detection , Reproducibility of Results , Tandem Mass Spectrometry/methods