Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Inflamm Bowel Dis ; 26(10): 1588-1596, 2020 09 18.
Article in English | MEDLINE | ID: mdl-32725166

ABSTRACT

BACKGROUND: Inflammatory bowel disease (IBD) can manifest both macroscopically and microscopically in the oral cavity; however, little is known about salivary changes in IBD. Therefore, this study aimed to assess salivary and circulatory inflammatory profiles in IBD and to compare their potential to reflect the presence and activity of IBD. METHODS: We measured 92 known inflammatory proteins in serum and in unstimulated and stimulated whole saliva samples from patients with IBD with active intestinal inflammation (n = 21) and matched control patients (n = 22) by proximity extension assay. Fifteen of the patients with IBD returned 10 to 12 weeks after treatment escalation for resampling. RESULTS: Sixty-seven of the proteins were detected in all 3 sample fluids but formed distinct clusters in serum and saliva. Twenty-one inflammatory proteins were significantly increased and 4 were significantly decreased in the serum of patients with IBD compared with that of the control patients. Two of the increased serum proteins, IL-6 and MMP-10, were also significantly increased in stimulated saliva of patients with IBD and correlated positively to their expressions in serum. None of the investigated proteins in serum or saliva were significantly altered by IBD treatment at follow-up. Overall, inflammatory proteins in serum correlated to biochemical status, and salivary proteins correlated positively to clinical parameters reflecting disease activity. CONCLUSIONS: Saliva and serum inflammatory profiles in IBD share a similar composition but reflect different aspects of disease activity. The oral cavity reflects IBD through elevated IL-6 and MMP-10 in stimulated saliva.


Subject(s)
Inflammation Mediators/metabolism , Inflammatory Bowel Diseases/metabolism , Saliva/chemistry , Serum/chemistry , Severity of Illness Index , Adult , Case-Control Studies , Female , Humans , Interleukin-6/metabolism , Male , Matrix Metalloproteinase 10/metabolism , Middle Aged
2.
Scand J Gastroenterol ; 49(9): 1084-90, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24853318

ABSTRACT

OBJECTIVE: Capsule endoscopy (CE) is a sensitive method for detecting inflammatory lesions in the small bowel. Such lesions may be due to Crohn's disease but also to other causes and a histological diagnosis may be difficult to achieve in the small bowel. The aim of the study was to find a possible correlation between capsule endoscopic findings, biochemical parameters, and symptoms in patients with suspected or known small-bowel Crohn´s disease. MATERIALS AND METHODS: Thirty patients with inflammatory lesions in the small bowel diagnosed by CE were included. CE findings of inflammation were graded using the Lewis score. C-reactive protein (CRP) and fecal calprotectin were used as biochemical parameters. Symptoms were graded using the Harvey-Bradshaw index. The patients were followed up after 9 months with a second CE, CRP, fecal calprotectin, and Harvey-Bradshaw index. RESULTS: There was a significant persistent correlation between endoscopic inflammation and fecal calprotectin (p = 0.003 at inclusion and p < 0.001 at follow-up). CRP was correlated to endoscopic inflammation at inclusion (p = 0.006), but not at follow-up. Symptoms were not correlated with endoscopic inflammation. CONCLUSION: Inflammatory lesions in the small bowel diagnosed by CE in patients with suspected Crohn´s disease are correlated to fecal calprotectin and CRP, but not to symptoms.


Subject(s)
C-Reactive Protein/metabolism , Crohn Disease/pathology , Feces/chemistry , Ileitis/pathology , Leukocyte L1 Antigen Complex/analysis , Adult , Aged , Biomarkers/analysis , Biomarkers/blood , Capsule Endoscopy , Crohn Disease/blood , Female , Humans , Ileitis/blood , Male , Middle Aged , Prospective Studies , Severity of Illness Index , Young Adult
3.
Gastroenterol Res Pract ; 2012: 518718, 2012.
Article in English | MEDLINE | ID: mdl-21969823

ABSTRACT

UNLABELLED: Aim. To evaluate capsule endoscopy in terms of incomplete examinations and capsule retentions and to find risk factors for these events. Material and Methods. This retrospective and consecutive study includes data from 2300 capsule enteroscopy examinations, performed at four different hospitals in Stockholm, Sweden from 2003 to 2009. Results. The frequency of incomplete examinations was 20%. Older age, male gender, suspected, and known Crohn's disease were risk factors for an incomplete examination. The PillCam capsule had the highest rate of completed examinations. Capsule retention occurred in 1.3% (n = 31). Risk factors for capsule retention were known Crohn's disease and suspected tumor. Complications of capsule retention were acute obstructive symptoms in six patients and one death related to complications after acute surgical capsule retrieval. CONCLUSION: Capsule endoscopy is considered a safe procedure, although obstructive symptoms and serious complications due to capsule retention can be found in a large series of patients.

4.
BMC Gastroenterol ; 10: 113, 2010 Sep 28.
Article in English | MEDLINE | ID: mdl-20920209

ABSTRACT

BACKGROUND: Angioectasias in the gastrointestinal tract can be found in up to 3% of the population. They are typically asymptomatic but may sometimes result in severe bleeding. The reasons for why some patients bleed from their angioectasias are not fully understood but it has been reported that it may be explained by an acquired von Willebrand syndrome (AVWS). This condition has similar laboratory findings to congenital von Willebrand disease with selective loss of large von Willebrand multimers. The aim of this study was to find out if AVWS or any other bleeding disorder was more common in patients with bleeding from angioectasias than in a control group. METHODS: We compared bleeding tests and coagulation parameters, including von Willebrand multimers, from a group of 23 patients with anemia caused by bleeding from angioectasias, with the results from a control group lacking angioectasias. RESULTS: No significant differences between the two groups were found in coagulation parameters, bleeding time or von Willebrand multimer levels. CONCLUSION: These results do not support a need for routine bleeding tests in cases of bleeding from angioectasias and do not show an overall increased risk of AVWS among these patients.


Subject(s)
Angiodysplasia/complications , Blood Coagulation Disorders/diagnosis , Blood Coagulation Factors/metabolism , Gastrointestinal Hemorrhage/etiology , Gastrointestinal Tract/blood supply , Adult , Aged , Aged, 80 and over , Angiodysplasia/blood , Angiodysplasia/diagnosis , Bleeding Time , Capsule Endoscopy/methods , Diagnosis, Differential , Female , Gastrointestinal Hemorrhage/blood , Gastrointestinal Hemorrhage/diagnosis , Humans , Male , Middle Aged , Retrospective Studies
5.
Anticancer Res ; 29(5): 1539-45, 2009 May.
Article in English | MEDLINE | ID: mdl-19443363

ABSTRACT

BACKGROUND: The size of colorectal neoplastic polyps is important for their clinical management. MATERIALS AND METHODS: The size of 12 polyp phantoms was assessed in tandem colonoscopies carried out by 7 endoscopists differing in years of clinical endoscopical experience. The endoscopists measured, with (n=5) or without (n=2) the aid of open forceps, the largest diameter of 12 polyp phantoms. Measurements in two independent trials were compared with the gold standard-size assessed at The Department of Production Engineering, The Royal Institute of Technology. RESULTS: In tandem trials, 99.4% (167/168) of the measurements underscored the gold standard size. In the 1st trial, the size in all 84 measurements was underestimated by -40% (range -34% to -45%) and in the 2nd trial the size in 83 of the 84 measurements was underestimated by -34% (range -24% to -42%). Neither the age of the participant, nor the years of experience with clinical endoscopy improved the results obtained. The participants significantly underestimated larger devices (>or=20 mm) whereas the smallest "polyps" were also underestimated, but with a lower degree of inaccuracy. The absolute difference between the golden standard size and the mean of all measurements performed on each polyp in 167 out of 168 measurements followed a regular downward trend. The volume of the devices was one of the confounding factors in size assessment. When compared to the gold standard size, the larger the "polyp" size, the higher the degree of underestimation. This may be crucial considering that the risk for colorectal adenomas to shelter an invasive growth is 46%, for adenomas measuring >or=2 cm, a limit accepted as a guideline worldwide for the management of patients with large colorectal polyps. CONCLUSION: Considering the clinical implications of the results obtained, the possibility of developing a method that would allow the assessment of the true size of polyps in clinical colonoscopy, is being explored.


Subject(s)
Colonic Polyps/pathology , Colonoscopy/methods , Phantoms, Imaging , Humans
6.
BMC Gastroenterol ; 7: 29, 2007 Jul 18.
Article in English | MEDLINE | ID: mdl-17640373

ABSTRACT

BACKGROUND: Capsule endoscopy (CE) is a unique tool to visualize the mucosa of the small intestine. Chronic intestinal dysmotility (CID) is a group of rare disorders of gastrointestinal motility that often are complicated by bacterial overgrowth. The aim of this study was to determine the prevalence of small bowel mucosal abnormalities in patients with CID. We also studied the usefulness of CE in the diagnosis of intestinal dysmotility. METHODS: We conducted a prospective study using CE in 18 patients; six with myopathic, 11 with neuropathic and one with indeterminate CID. A control group was used for comparison of small bowel transit. RESULTS: Mucosal breaks (erosions and ulcerations) were found in 16/18 (89%) patients. The capsule reached the caecum in 11/18 (61%) patients with a median transit time of 346 minutes. In the control group the capsule reached the caecum in 29/36 (81%) cases with a median transit time of 241 minutes. The difference in transit time was not significant (p = 0.061) in this material. The capsule was retained in the stomach in 3/18 patients. None of the patients developed symptoms or signs of mechanical obstruction. CONCLUSION: A high frequency of mucosal breaks and signs of motility disturbances were seen in CID patients. CE is feasible for the examination of small bowel mucosa in patients with CID. The relevance of observed mucosal abnormalities in CID remains uncertain.


Subject(s)
Capsule Endoscopy , Ileus/diagnosis , Ulcer/diagnosis , Adult , Aged , Aged, 80 and over , Case-Control Studies , Female , Humans , Ileus/epidemiology , Intestinal Mucosa , Intestine, Small , Male , Middle Aged , Prevalence , Prospective Studies , Ulcer/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...