Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Ned Tijdschr Tandheelkd ; 129(10): 449-453, 2022 Oct.
Article in Dutch | MEDLINE | ID: mdl-36222449

ABSTRACT

Portable intraoral X-ray devices are marketed as an alternative for conventional wall mounted devices. On the basis of a recent clinical trial the diagnostic quality of portables appears to measure up to the conventional devices. When CE-certified portable devices are used with rectangular collimation and a backshatter radiation shield with adapted technique resulting in a beam parallel to the ground, operator exposure stays well within dose limits. However, the dose to the operator is higher than when using conventional devices. Therefore, in the Netherlands, guidelines restrict the use of portable devices to ambulant use outside the dental clinic while deploying additional radiation protection measures. If presumed advantages of increased control over the exposure due to proximity to the patient would be substantiated by research, this restricted use could be reconsidered. Dentists should be aware of online availability of non-CE-certified portable intra-oral X-ray devices that are potentially unsafe.


Subject(s)
Radiation Protection , Radiography, Dental , Humans , Netherlands , Radiation Dosage , Radiography, Dental/methods , X-Rays
2.
Ned Tijdschr Tandheelkd ; 129(7-8): 323-326, 2022 Jul.
Article in Dutch | MEDLINE | ID: mdl-35833280

ABSTRACT

During intraoral radiography of the upper anterior teeth, the dose the patient is exposed to can be reduced by shielding the thyroid area by using a thyroid shield or collar. However, the dose to the patient is already low and it is questionable whether efforts to reduce this even further are sensible. A cost-utility analysis demonstrated that thyroid shielding is utile when it is used at least 24 times per year for upper anterior exposures in children.


Subject(s)
Radiation Protection , Thyroid Gland , Child , Cost-Benefit Analysis , Humans , Radiation Dosage
3.
Neth Heart J ; 30(1): 47-57, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34259995

ABSTRACT

Cardiovascular disease (CVD) is a major cause of morbidity and mortality worldwide. For many years guidelines have listed optimal preventive therapy. More recently, novel therapeutic options have broadened the options for state-of-the-art CV risk management (CVRM). In the majority of patients with CVD, risk lowering can be achieved by utilising standard preventive medication combined with lifestyle modifications. In a minority of patients, add-on therapies should be considered to further reduce the large residual CV risk. However, the choice of which drug combination to prescribe and in which patients has become increasingly complicated, and is dependent on both the absolute CV risk and the reason for the high risk. In this review, we discuss therapeutic decisions in CVRM, focusing on (1) the absolute CV risk of the patient and (2) the pros and cons of novel treatment options.

4.
Rev Sci Instrum ; 92(3): 033103, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33820098

ABSTRACT

In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TESs) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes, however, pose a limit on the accuracy of the effective filter resonance frequencies. Off-resonance bias carriers could be used to suppress the impact of intermodulation distortions, which, nonetheless, would significantly affect the effective bias circuit and the detector spectral performance. In this paper, we present a frequency shift algorithm (FSA) to allow off-resonance readout of TESs, while preserving the on-resonance bias circuit and spectral performance, demonstrating its application to the FDM readout of an x-ray TES microcalorimeter array. We discuss the benefits in terms of mitigation of the impact of intermodulation distortions at the cost of increased bias voltage and the scalability of the algorithm to multi-pixel FDM readout. We show that with FSA, in the multi-pixel and frequencies shifted on-grid, the line noises due to intermodulation distortion are placed away from the sensitive region in the TES response and the x-ray performance is consistent with the single-pixel, on-resonance level.

5.
Ned Tijdschr Geneeskd ; 1642020 10 22.
Article in Dutch | MEDLINE | ID: mdl-33201620

ABSTRACT

Atherosclerosis is a lipid-driven inflammatory disease, in which both lipids and inflammation can be considered treatment targets. The CANTOS-trial, using the IL-1ß monoclonal antibody canakinumab, has proven the concept of targeting inflammation to reduce cardiovascular risk. In contrast, the anti-inflammatory drug methotrexate failed to show cardiovascular benefit. Colchicine is a drug used in gout patients, acting as a non-selective inflammasome inhibitor. The COLCOT-trial uncovered a significant reduction in ischemic cardiovascular events in subjects following an acute myocardial infarction, which was recently confirmed in the larger LoDoCo2-trial in stable coronary heart disease. Guideline committees will have to decide whether the trials have supplied sufficient evidence to implement the routine use of colchicine in the guidelines for cardiovascular risk management. These convincing endpoint trials have paved the way for tailored treatment regimens, comprising anti-inflammatory agents besides currently established treatment modalities in CVRM.


Subject(s)
Anti-Inflammatory Agents/therapeutic use , Cardiovascular Diseases/drug therapy , Myocardial Infarction/drug therapy , Practice Guidelines as Topic , Translational Research, Biomedical/trends , Antibodies, Monoclonal, Humanized/therapeutic use , Colchicine/therapeutic use , Humans , Inflammation , Methotrexate/therapeutic use , Randomized Controlled Trials as Topic
6.
Surg Radiol Anat ; 42(9): 1063-1071, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32653942

ABSTRACT

PURPOSE: Determination of intra-oral surface areas might contribute to our understanding of the physiology of the oral cavity and oral diseases. In previous studies, the intra-oral surface area was determined using a laborious and technically challenging method. Our aim was to develop an easy and non-invasive method to determine the intra-oral surface areas. METHODS: In this study, we used cone-beam computed tomography (CBCT) and digital analysis in 20 human cadavers to determine various intra-oral surface areas, based on digital segmentation. Next, we explored whether there was a relationship between various intra-oral surface areas and anthropometric measurements of the head using Pearson correlation coefficient. RESULTS: Using CBCT and digital analysis, it was possible to determine various intra-oral surface areas. On average, the total intra-oral surface area was 173 ± 19 cm2. Moderate, statistical significant correlations were observed between (1) the length of the head and the palatal surface area, as well as (2) the depth of the head and the surface area of the tongue. These correlations suggest the feasibility of estimating intra-oral surface areas without relying on CBCT imaging. CONCLUSIONS: This study presents a technique for measuring the intra-oral surface areas by CBCT imaging in combination with digital analysis. The results of this study suggest that anthropometric measurements of the head might be used to estimate the surface areas of the palate and tongue.


Subject(s)
Cephalometry , Cone-Beam Computed Tomography , Imaging, Three-Dimensional , Mouth/anatomy & histology , Cadaver , Humans , Mouth/diagnostic imaging
7.
J Thromb Haemost ; 16(10): 1964-1972, 2018 10.
Article in English | MEDLINE | ID: mdl-30007116

ABSTRACT

Essentials Inflammatory and cardiac diseases are associated with increased venous thromboembolism (VTE) risk. Our prospective study assessed rise in inflammatory or cardiac biomarkers and VTE risk. A greater 6-year rise in N-terminal natriuretic peptide is associated with increased VTE incidence. Volume overload or impending cardiac disease may contribute to VTE occurrence. SUMMARY: Background We previously showed that participants in the population-based Atherosclerosis Risk in Communities (ARIC) cohort with elevated levels of blood biomarkers of inflammation or cardiac disease were at increased risk of venous thromboembolism (VTE). Objective We hypothesized that ARIC participants with larger 6-year increases in the levels of three biomarkers - C-reactive protein (CRP), N-terminal pro-B-type natriuretic peptide (NT-proBNP), and troponin T - would also have an increased subsequent risk of VTE. Methods We measured changes in the levels of these biomarkers in 9844 participants from 1990-1992 to 1996-1998, and then identified VTEs through 2015. Results A greater 6-year rise in the level of NT-proBNP, but not in that of CRP or troponin T, was significantly associated with increased VTE incidence over a median of 17.6 years of follow-up. After adjustment for other VTE risk factors, those whose NT-proBNP level rose from < 100 pg mL-1 to ≥ 100 pg mL-1 had a hazard ratio for VTE of 1.44 (95% confidence interval [CI] 1.15-1.80), as compared with the reference group with an NT-proBNP level of < 100 pg mL-1 at both times. This hazard ratio was slightly higher (1.66, 95% CI 1.19-2.31) during the first 10 years of follow-up, but was attenuated (1.24, 95% CI 0.99-1.56) after adjustment for prevalent and incident coronary heart disease, heart failure, and atrial fibrillation. Conclusions The two most likely explanations for our results are that: (i) an increasing NT-proBNP level reflects increasing subclinical volume overload and potentially increased venous stasis or subclinical PE that had gone unrecognized over time; or (ii) an increasing NT-proBNP level is a risk marker for impending cardiac disease that places patients at risk of VTE.


Subject(s)
Cardiovascular Diseases/epidemiology , Inflammation Mediators/blood , Inflammation/epidemiology , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Venous Thromboembolism/epidemiology , Biomarkers/blood , C-Reactive Protein/metabolism , Cardiovascular Diseases/blood , Cardiovascular Diseases/diagnosis , Female , Humans , Incidence , Inflammation/blood , Inflammation/diagnosis , Longitudinal Studies , Male , Middle Aged , Prognosis , Prospective Studies , Risk Assessment , Risk Factors , Time Factors , Troponin T/blood , United States/epidemiology , Up-Regulation , Venous Thromboembolism/blood , Venous Thromboembolism/diagnosis
8.
Neth J Med ; 74(2): 89-92, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26951355

ABSTRACT

In the Netherlands dapsone is used for the treatment of dermatitis herpetiformis, leprosy and Pneumocystis jiroveci pneumonia and prophylaxis in case of cotrimoxazole allergy. An idiosyncratic drug reaction, known as the dapsone hypersensitivity syndrome (DHS), appears in about 0.5-3.6% of persons treated with dapsone. DHS can be associated with fever, rash and systemic involvement. We present a 35-year-old woman who developed severe DHS seven weeks after starting dapsone. Six weeks after being discharged in a good clinical condition she died from fulminant myocarditis, 11 weeks after the first DHS symptoms and the discontinuation of dapsone.


Subject(s)
Dapsone/adverse effects , Drug Hypersensitivity/etiology , Heart/drug effects , Myocardium/pathology , Adult , Dapsone/therapeutic use , Drug Hypersensitivity/diagnosis , Fatal Outcome , Female , Humans , Leprostatic Agents/adverse effects , Leprostatic Agents/therapeutic use , Leprosy/drug therapy , Syndrome
9.
Diabet Med ; 33(7): 968-75, 2016 07.
Article in English | MEDLINE | ID: mdl-26433129

ABSTRACT

AIM: To investigate the genetic influence of circulating lactate level, a marker of oxidative capacity associated with diabetes. METHODS: We conducted a genome-wide association study of log-transformed plasma lactate levels in 6901 European-American participants in the Atherosclerosis Risk in Communities study. For regions that achieved genome-wide significance in European-American participants, we conducted candidate region analysis in African-American subjects and tested for interaction between metformin use and the index single nucleotide polymorphisms for plasma lactate in European-American subjects. RESULTS: The genome-wide association study in European-American subjects identified two genome-wide significant loci, GCKR (rs1260326, T allele ß=0.08; P=1.8×10(-47) ) and PPP1R3B/LOC157273 (rs9987289, A allele ß=0.06; P=1.6×10(-9) ). The index single nucleotide polymorphisms in these two loci explain 3.3% of the variance in log-transformed plasma lactate levels among the European-American subjects. In the African-American subjects, based on a region-significant threshold, the index single nucleotide polymorphism at GCKR was associated with plasma lactate but that at PPP1R3B/LOC157273 was not. Metformin use appeared to strengthen the association between the index single nucleotide polymorphism at PPP1R3B/LOC157273 and plasma lactate in European-American subjects (P for interaction=0.01). CONCLUSIONS: We identified GCKR and PPP1R3B/LOC157273 as two genome-wide significant loci of plasma lactate. Both loci are associated with other diabetes-related phenotypes. These findings increase our understanding of the genetic control of lactate metabolism.


Subject(s)
Adaptor Proteins, Signal Transducing/genetics , Lactic Acid/blood , Protein Phosphatase 1/genetics , Black or African American , Alleles , Cohort Studies , Diabetes Mellitus, Type 2/blood , Diabetes Mellitus, Type 2/drug therapy , Female , Genome-Wide Association Study , Humans , Hypoglycemic Agents/therapeutic use , Male , Metformin/therapeutic use , Middle Aged , Phenotype , Polymorphism, Single Nucleotide , White People
10.
Diabet Med ; 33(10): 1392-8, 2016 10.
Article in English | MEDLINE | ID: mdl-26359784

ABSTRACT

AIMS: To verify whether elevated fasting levels of circulating carboxymethyl lysine (CML), an advanced glycation end product, predict the development of diabetes in middle-age adults. METHODS: Using a stratified case-cohort design, we followed 543 middle-aged individuals who developed diabetes and 514 who did not over a median 9 years in the Atherosclerosis Risk in Communities Study. Weighted Cox proportional hazards analyses were used to account for the design. RESULTS: In weighted analyses, correlation between CML levels and anthropometric, inflammatory or metabolic variables was minimal (Pearson correlations usually < 0.10). CML, when modelled as a continuous variable and after adjustment for age, sex, race, centre, parental history of diabetes, BMI, waist-to-hip ratio, non-esterified fatty acids, oxidized LDL-cholesterol, GFR, smoking, an inflammation score, adiponectin, leptin, insulin and glucose levels, was associated with an increased risk of diabetes [Hazard ratio (HR) = 1.35; 95% confidence interval (CI) 1.09-1.67, for each 100 ng/ml CML increment]. Baseline glucose level and race each modified the association (P < 0.05 for interaction), which was present only among those with impaired fasting glucose (≥ 5.6 mmol/l, HR = 1.61, 95% CI 1.26-2.05) and among white participants (HR = 1.50, 95% CI 1.13-1.99). CONCLUSIONS: Elevated fasting CML, after adjustment for multiple risk factors for diabetes, predicts the development of incident diabetes, the association being present among those with impaired fasting glucose and in white participants. These prospective findings suggest that advanced glycation end products might play a role in the development of diabetes.


Subject(s)
Diabetes Mellitus/blood , Diabetes Mellitus/epidemiology , Lysine/analogs & derivatives , Atherosclerosis/blood , Case-Control Studies , Cohort Studies , Diabetic Angiopathies/blood , Diabetic Angiopathies/epidemiology , Female , Glycation End Products, Advanced/blood , Humans , Incidence , Lysine/blood , Male , Middle Aged , Risk Factors
11.
HIV Med ; 17(4): 289-97, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26268806

ABSTRACT

OBJECTIVES: The aim of the study was to compare the predictions of five popular cardiovascular disease (CVD) risk prediction models, namely the Data Collection on Adverse Events of Anti-HIV Drugs (D:A:D) model, the Framingham Heart Study (FHS) coronary heart disease (FHS-CHD) and general CVD (FHS-CVD) models, the American Heart Association (AHA) atherosclerotic cardiovascular disease risk score (ASCVD) model and the Systematic Coronary Risk Evaluation for the Netherlands (SCORE-NL) model. METHODS: A cross-sectional design was used to compare the cumulative CVD risk predictions of the models. Furthermore, the predictions of the general CVD models were compared with those of the HIV-specific D:A:D model using three categories (< 10%, 10-20% and > 20%) to categorize the risk and to determine the degree to which patients were categorized similarly or in a higher/lower category. RESULTS: A total of 997 HIV-infected patients were included in the study: 81% were male and they had a median age of 46 [interquartile range (IQR) 40-52] years, a known duration of HIV infection of 6.8 (IQR 3.7-10.9) years, and a median time on ART of 6.4 (IQR 3.0-11.5) years. The D:A:D, ASCVD and SCORE-NL models gave a lower cumulative CVD risk, compared with that of the FHS-CVD and FHS-CHD models. Comparing the general CVD models with the D:A:D model, the FHS-CVD and FHS-CHD models only classified 65% and 79% of patients, respectively, in the same category as did the D:A:D model. However, for the ASCVD and SCORE-NL models, this percentage was 89% and 87%, respectively. Furthermore, FHS-CVD and FHS-CHD attributed a higher CVD risk to 33% and 16% of patients, respectively, while this percentage was < 6% for ASCVD and SCORE-NL. CONCLUSIONS: When using FHS-CVD and FHS-CHD, a higher overall CVD risk was attributed to the HIV-infected patients than when using the D:A:D, ASCVD and SCORE-NL models. This could have consequences regarding overtreatment, drug-related adverse events and drug-drug interactions.


Subject(s)
Anti-HIV Agents/adverse effects , Antiretroviral Therapy, Highly Active/adverse effects , Cardiovascular Diseases/epidemiology , HIV Infections/drug therapy , Adolescent , Adult , Aged , Aged, 80 and over , Anti-HIV Agents/therapeutic use , Cardiovascular Diseases/etiology , Cross-Sectional Studies , Female , HIV Infections/complications , Humans , Male , Middle Aged , Models, Theoretical , Netherlands , Risk Assessment , United States , Young Adult
12.
Ned Tijdschr Tandheelkd ; 122(5): 287-92, 2015 May.
Article in Dutch | MEDLINE | ID: mdl-26210221

ABSTRACT

Soon after the discovery of X-rays, it became clear that their use can cause detrimental effects. The field of radiobiology deals with these detrimental effects. In this article, the theoretical concepts of radiobiology relevant to diagnostic X-ray use are presented. The effects of radiation on living tissues, the relationship between dose and effect, and a translation of these effects into the dental application are discussed. X-rays cannot be considered to be harmless even when used at the relatively low doses as in dentistry. If applied with justification and optimization, the risk to the patient will, however, be small.


Subject(s)
Patient Safety , Radiography, Dental/adverse effects , Risk Assessment , X-Rays/adverse effects , Dose-Response Relationship, Radiation , Humans , Radiation Dosage
13.
Dentomaxillofac Radiol ; 44(9): 20150158, 2015.
Article in English | MEDLINE | ID: mdl-26119214

ABSTRACT

OBJECTIVES: To find a method that is suitable for providing an objective assessment of the cost effectiveness of a dose-reducing measure used for diagnostic dental X-ray exposures. METHODS: Three cost-utility analysis (CUA) methods were evaluated by comparing their assessments of two dose-reduction measures, a rectangular collimator and the combination of two devices that reduce the radiation dose received during orthodontic lateral cephalography. The following CUA methods were used: (1) the alpha value (AV), a monetary valuation of dose reduction used in the nuclear industry; (2) the value of a statistical life for valuation of the reduction in stochastic adverse effects; and (3) the time-for-time method, based on the postulate that risk reduction is effective when the number of years of life gained is more than the years that an average worker must work to earn the costs of the risk-reducing measure. The CUA methods were used to determine the minimum number of uses that was required for the dose-reducing device to be cost effective. The methods were assessed for coherence (are comparable results achieved for comparable countries?) and adaptability (can the method be adjusted for age and gender of specific patient groups?). RESULTS: The performance of the time-for-time method was superior to the other methods. Both types of dose-reduction devices tested were assessed as cost effective after a realistic number of uses with all three methods except low AVs. CONCLUSIONS: CUA for the methods of X-ray dose reduction can be performed to determine if investment in low dose reduction is cost effective. The time-for-time method proved to be a coherent and versatile method for performing CUA.


Subject(s)
Radiation Dosage , Radiation Protection/methods , Radiography, Dental/methods , Age Factors , Algorithms , Cephalometry/economics , Cephalometry/instrumentation , Cephalometry/methods , Cost-Benefit Analysis , Humans , Radiation Injuries/economics , Radiation Injuries/prevention & control , Radiation Protection/economics , Radiation Protection/instrumentation , Radiography, Dental/economics , Radiography, Dental/instrumentation , Sex Factors , Stochastic Processes , Value of Life
14.
Dentomaxillofac Radiol ; 44(4): 20140260, 2015.
Article in English | MEDLINE | ID: mdl-25564885

ABSTRACT

OBJECTIVES: To test the dose-reducing capabilities of a novel thyroid protection device and a recently introduced cranial collimator to be used in orthodontic lateral cephalography. METHODS: Cephalographic thyroid protector (CTP) was designed to shield the thyroid while leaving the cervical vertebrae depicted. Using a RANDO(®) head phantom (The Phantom Laboratory, Salem, NY) equipped with dosemeters and a Proline XC (Planmeca, Helsinki, Finland) cephalograph, lateral cephalograms were taken, and the effective dose (ED) was calculated for four protocols: (1) without shielding; (2) with CTP; (3) with CTP and anatomical cranial collimator (ACC); and (4) with a thyroid collar (TC). RESULTS: The ED for the respective protocols was (1) 8.51; (2) 5.39; (3) 3.50; and (4) 4.97 µSv. The organ dose for the thyroid was reduced from 30.17 to 4.50 µSv in Protocols 2 and 3 and to 3.33 µSv in Protocol 4. CONCLUSIONS: The use of just the CTP (Protocol 2) resulted in a 36.8% reduction of the ED of a lateral cephalogram. This was comparable to the classical TC (Protocol 4). A 58.8% reduction of the ED was obtained when combining CTP and ACC (Protocol 3). The dose to the radiosensitive thyroid gland was reduced by 85% in Protocols 2 and 3 and by 89% in Protocol 4.


Subject(s)
Cephalometry/methods , Radiation Dosage , Radiation Protection/instrumentation , Algorithms , Brain/radiation effects , Cephalometry/instrumentation , Cervical Vertebrae/diagnostic imaging , Cheek/radiation effects , Equipment Design , Esophagus/radiation effects , Humans , Mandible/radiation effects , Mouth Floor/radiation effects , Neck Muscles/radiation effects , Orbit/radiation effects , Orthodontics , Parotid Gland/radiation effects , Phantoms, Imaging , Radiography , Skull/radiation effects , Submandibular Gland/radiation effects , Thermoluminescent Dosimetry/instrumentation , Thyroid Gland/radiation effects
15.
Biomed Res Int ; 2015: 596858, 2015.
Article in English | MEDLINE | ID: mdl-26881200

ABSTRACT

OBJECTIVE: To investigate if software simulation is practical for quantifying random error (RE) in phantom dosimetry. MATERIALS AND METHODS: We applied software error simulation to an existing dosimetry study. The specifications and the measurement values of this study were brought into the software (R version 3.0.2) together with the algorithm of the calculation of the effective dose (E). Four sources of RE were specified: (1) the calibration factor; (2) the background radiation correction; (3) the read-out process of the dosimeters; and (4) the fluctuation of the X-ray generator. RESULTS: The amount of RE introduced by these sources was calculated on the basis of the experimental values and the mathematical rules of error propagation. The software repeated the calculations of E multiple times (n = 10,000) while attributing the applicable RE to the experimental values. A distribution of E emerged as a confidence interval around an expected value. CONCLUSIONS: Credible confidence intervals around E in phantom dose studies can be calculated by using software modelling of the experiment. With credible confidence intervals, the statistical significance of differences between protocols can be substantiated or rejected. This modelling software can also be used for a power analysis when planning phantom dose experiments.


Subject(s)
Computer Simulation/standards , Phantoms, Imaging , Radiometry/instrumentation , Radiometry/standards , Software
16.
Dentomaxillofac Radiol ; 43(3): 20130396, 2014.
Article in English | MEDLINE | ID: mdl-24720607

ABSTRACT

The use of an anatomically shaped cranial collimator (ACC) to reduce patient dose in orthodontic lateral cephalography was investigated in this study. The aim was to evaluate the potential interference of the ACC on landmark identification for orthodontic cephalometry. Consecutive orthodontic patients underwent a total of 100 cephalograms using an ACC mounted on a Veraviewepocs(®) 3D X550 (J. Morita Co., Kyoto, Japan) X-ray unit. 10 observers were asked whether the identification of 5 landmarks close to the collimated area was hindered or rendered impossible by the presence of the collimator. Of the 500 landmarks that were judged by the 10 observers, 496 (99.2%) were reported to lack hindrance. In three landmarks, a minority of the observers reported hindrance. In 1 landmark, 8 of the 10 observers reported hindrance by the collimator. In no instance did the observers state that the identification of landmarks was impossible as a result of the collimation. Application of the ACC on the cephalostat of the X-ray unit is a viable way of reducing patient dose, as it only marginally interferes with the diagnostic yield of the exposure. The need to retake images when the ACC is applied was found to be extremely low.


Subject(s)
Anatomic Landmarks/diagnostic imaging , Cephalometry/instrumentation , Facial Bones/diagnostic imaging , Orthodontics/instrumentation , Radiation Protection/instrumentation , Cephalometry/methods , Child , Ear Canal/diagnostic imaging , Equipment Design , Female , Forehead/diagnostic imaging , Humans , Male , Nasal Bone/diagnostic imaging , Radiation Dosage , Radiography , Sella Turcica/diagnostic imaging , Skull Base/diagnostic imaging
17.
Dentomaxillofac Radiol ; 43(1): 20130203, 2014.
Article in English | MEDLINE | ID: mdl-24170799

ABSTRACT

Lateral cephalograms in orthodontic practice display an area cranial of the base of the skull that is not required for diagnostic evaluation. Attempts have been made to reduce the radiation dose to the patient using collimators combining the shielding of the areas above the base of the skull and below the mandible. These so-called "wedge-shaped" collimators have not become standard equipment in orthodontic offices, possibly because these collimators were not designed for today's combination panoramic-cephalometric imaging systems. It also may be that the anatomical variability of the area below the mandible makes this area unsuitable for standardized collimation. In addition, a wedge-shaped collimator shields the cervical vertebrae; therefore, assessment of skeletal maturation, which is based on the stage of development of the cervical vertebrae, cannot be performed. In this report, we describe our investigations into constructing a collimator to be attached to the cephalostat and shield the cranial area of the skull, while allowing the visualization of diagnostically relevant structures and markedly reducing the size of the irradiated area. The shape of the area shielded by this "anatomically shaped cranial collimator" (ACC) was based on mean measurements of cephalometric landmarks of 100 orthodontic patients. It appeared that this collimator reduced the area of irradiation by almost one-third without interfering with the imaging system or affecting the quality of the image. Further research is needed to validate the clinical efficacy of the collimator.


Subject(s)
Cephalometry/instrumentation , Radiation Protection/instrumentation , Skull/diagnostic imaging , Adolescent , Anatomic Landmarks/anatomy & histology , Cephalometry/methods , Computer-Aided Design , Equipment Design , Female , Humans , Male , Orthodontics/instrumentation , Radiation Dosage , Radiation Protection/methods , Radiographic Image Enhancement/methods , Radiography, Panoramic/instrumentation , Skull/anatomy & histology , Surface Properties
18.
Dentomaxillofac Radiol ; 42(6): 20120423, 2013.
Article in English | MEDLINE | ID: mdl-23412462

ABSTRACT

OBJECTIVES: During a cone beam CT scan, the patient is in an upright or supine position. This position depends on the brand and type of the scanner. The aims of this study are: (1) to investigate if the head position has an effect on cephalometric evaluation of the soft-tissue facial profile, comparing the recordings in natural head position (NHP) and supine head position (SHP) and (2) to investigate if age, gender and body mass index (BMI) are contributing factors to the effect of the head position. METHODS: 90 subjects were photographed in profile both in NHP and in SHP. 12 soft-tissue angular and linear cephalometric values were calculated. Two-way random intraclass correlation coefficients were calculated to determine observer reliability. Paired t-tests and linear regression analyses were performed to investigate the differences between the head positions and the influence of age, gender and BMI. RESULTS: Intraobserver reliability was generally high. Paired t-tests showed significant changes as a result of head positioning (p < 0.0001) in 9 of the 12 measurements. These differences were small and clinically not relevant, except for the "lower face-throat angle". Regression analysis revealed no relevant influence of age, gender and BMI. CONCLUSIONS: Cephalometric soft-tissue evaluation from a recording in SHP is generally reliable, except for the throat-chin area where a clinically relevant difference was found. The contour of the submandibular tissues in SHP causes the chin to appear more prominently. This can cause incorrect orthodontic diagnosis and treatment planning.


Subject(s)
Cephalometry/methods , Cone-Beam Computed Tomography/methods , Face/anatomy & histology , Head/anatomy & histology , Adult , Age Factors , Body Mass Index , Cephalometry/statistics & numerical data , Chin/anatomy & histology , Cone-Beam Computed Tomography/statistics & numerical data , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Middle Aged , Neck/anatomy & histology , Observer Variation , Photography/methods , Posture/physiology , Reproducibility of Results , Sex Factors , Supine Position/physiology , Young Adult
19.
Magn Reson Imaging Clin N Am ; 17(1): 63-75, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19364600

ABSTRACT

Four-dimensional time-resolved MR angiography (4D-MRA) using keyhole imaging techniques is a new method of performing contrastenhanced vascular imaging. Combining parallel imaging and keyhole imaging techniques, it is possible to obtain dynamic MRA scans up to 60 times faster, thereby achieving subsecond sampling of the contrast hemodynamics. Furthermore, imaging at 3 T gives higher signal, thus affording higher spatial resolution and allowing dynamic 3D MRA to approach the diagnostic performance of conventional digital subtraction angiography. This article presents the authors' clinical experience using 4D-MRA to evaluate various vascular abnormalities in the brain, spine, orbits, and neck at 3 T, demonstrates the imaging findings of this novel technique, and discusses its advantages and use in current neuroradiology practice.


Subject(s)
Cerebrovascular Disorders/diagnosis , Image Enhancement/methods , Magnetic Resonance Angiography/methods , Adult , Arteriovenous Fistula/diagnosis , Carotid Artery Diseases/diagnosis , Cerebral Angiography/methods , Contrast Media , Female , Humans , Image Interpretation, Computer-Assisted/methods , Intracranial Arteriovenous Malformations/diagnosis , Male , Meglumine/analogs & derivatives , Middle Aged , Organometallic Compounds , Venous Thrombosis/diagnosis
20.
Med Biol Eng Comput ; 46(11): 1085-95, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18810521

ABSTRACT

Diagnosis of vascular disease and selection and planning of therapy are to a large extent based on the geometry of the diseased vessel. Treatment of a particular vascular disease is usually considered if the geometrical parameter that characterizes the severity of the disease, e.g. % vessel narrowing, exceeds a threshold. The thresholds that are used in clinical practice are based on epidemiological knowledge, which has been obtained by clinical studies including large numbers of patients. They may apply "on average", but they can be sub-optimal for individual patients. To realize more patient-specific treatment decision criteria, more detailed knowledge may be required about the vascular hemodynamics, i.e. the blood flow and pressure in the diseased vessel and the biomechanical reaction of the vessel wall to this flow and pressure. Over the last decade, a substantial number of publications have appeared on hemodynamic modeling. Some studies have provided first evidence that this modeling may indeed be used to support therapeutic decisions. The goal of the research reported in this paper is to go one step further, namely to investigate the feasibility of a patient-specific hemodynamic modeling methodology that is not only effective (improves therapeutic decisions), but that is also efficient (easy to use, fast, as much as possible automatic) and robust (insensitive to variation in the quality of the input data, same outcome for different users). A review is presented of our research performed during the last 5 years and the results that were achieved. This research focused on the risk assessment for one particular disease, namely abdominal aortic aneurysm, a life-threatening dilatation of the abdominal aorta.


Subject(s)
Aortic Aneurysm, Abdominal/diagnosis , Models, Cardiovascular , Risk Assessment/methods , Computer Simulation , Feasibility Studies , Hemodynamics , Hemorheology , Humans , Magnetic Resonance Imaging , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...