1.
Rev Sci Instrum ; 92(2): 023305, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33648127

ABSTRACT

In this paper, we report studies of the Fermi potential and loss per bounce of ultracold neutrons (UCNs) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enable its use in a wide variety of applications in fundamental neutron research.

2.
Rev Sci Instrum ; 84(1): 013904, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23387665

ABSTRACT

The impact system for ultrafast synchrotron experiments, or IMPULSE, is a 12.6-mm bore light-gas gun (<1 km/s projectile velocity) designed specifically for performing dynamic compression experiments using the advanced imaging and X-ray diffraction methods available at synchrotron sources. The gun system, capable of reaching projectile velocities up to 1 km/s, was designed to be portable for quick insertion/removal in the experimental hutch at Sector 32 ID-B of the Advanced Photon Source (Argonne, IL) while allowing the target chamber to rotate for sample alignment with the beam. A key challenge in using the gun system to acquire dynamic data on the nanosecond time scale was synchronization (or bracketing) of the impact event with the incident X-ray pulses (80 ps width). A description of the basic gun system used in previous work is provided along with details of an improved launch initiation system designed to significantly reduce the total system time from launch initiation to impact. Experiments were performed to directly measure the gun system time and to determine the gun performance curve for projectile velocities ranging from 0.3 to 0.9 km/s. All results show an average system time of 21.6 ± 4.5 ms, making it possible to better synchronize the gun system and detectors to the X-ray beam.

3.
Rev Sci Instrum ; 83(7): 073903, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22852700

ABSTRACT

The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial (∼2 µm) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

4.
Anal Bioanal Chem ; 395(2): 315-22, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19330320

ABSTRACT

The far infrared spectra of (100), (010), and (001)-oriented RDX single crystals were measured as the crystal was rotated about the axis perpendicular to the polarization plane of the incident radiation. Absorption measurements were taken at temperatures of both 20 K and 295 K for all rotations using terahertz time-domain spectroscopy. A number of discrete absorptions were found ranging from 10-100 cm(-1) (0.3-3 THz). The absorptions are highly dependent on the orientation of the terahertz polarization with respect to crystallographic axes.