1.
Front Pediatr ; 12: 1336154, 2024.
Article in English | MEDLINE | ID: mdl-38690521

ABSTRACT

Introduction: Recent evidence indicates that respiratory distress (RD) in near-term infants is caused by elevated airway liquid (EL) volume at the beginning of air-breathing after birth. While the adverse effects EL volumes on newborn lung function are known, the effects on respiratory control and breathing patterns shortly after birth (<4 h) are unknown. We investigated the effects of EL volumes on cardiorespiratory function and breathing patterns in spontaneously breathing near-term newborn lambs in the first hours after birth. Methods: At 137-8 days gestation (2-3 days prior to delivery; term ∼147 days), sterile surgery was performed on fetal sheep (n = 17) to implant catheters and blood flow probes. At 140 days, lambs were delivered via caesarean section under spinal anaesthesia. Airway liquid volumes were adjusted to mimic the level expected following vaginal delivery (∼10 ml/kg; Controls; n = 7), or elective caesarean section (∼30 ml/kg; elevated airway liquid group; EL; n = 10). Spontaneous breathing and cardiorespiratory parameters were recorded over four hours after birth. Non-invasive respiratory support with supplemental oxygen was provided if required. Results: EL lambs required higher inspired oxygen levels (p = 0.0002), were less active (p = 0.026), fed less (p = 0.008) and had higher respiratory morbidity scores than Controls (p < 0.0001). EL lambs also displayed higher rates of breathing patterns associated with RD, such as expiratory braking and tachypnoea. These patterns were particularly evident in male EL lambs who displayed higher levels of severe respiratory morbidity (e.g., expiratory braking) than female EL lambs. Conclusion: The study demonstrates that EL volumes at birth trigger respiratory behaviour and breathing patterns that resemble clinically recognised features of RD in term infants.

2.
Resuscitation ; 194: 110086, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38097106

ABSTRACT

BACKGROUND: During stabilisation of preterm infants at birth, a face mask is used to provide respiratory support. However, application of these masks may activate cutaneous stretch receptors of the trigeminal nerve, causing apnoea and bradycardia. This study investigated the amount of force exerted on the face mask during non-invasive ventilation of preterm infants at birth and whether the amount of exerted force is associated with apnoea and bradycardia. METHODS: A prospective observational study was performed in preterm infants born <32 weeks of gestation who were stabilised at birth. During the first 10 minutes of respiratory support, we measured breathing and heart rate as well as the amount of force exerted on a face mask using a custom-made pressure sensor placed on top of the face mask. RESULTS: Thirty infants were included (median (IQR) gestational age(GA) 28+3 (27+0-30+0) weeks, birthweight 1104 (878-1275) grams). The median exerted force measured was 297 (198-377) grams, ranging from 0 to 1455 grams. Significantly more force was exerted on the face mask during positive pressure ventilation when compared to CPAP (410 (256-556) vs 286 (190-373) grams, p = 0.009). In a binary logistic regression model, higher forces were associated with an increased risk of apnoea (OR = 1.607 (1.556-1.661), p < 0.001) and bradycardia (OR = 1.140 (1.102-1.180), p < 0.001) during the first 10 minutes of respiratory support at birth. CONCLUSION: During mask ventilation, the median exerted force on a face mask was 297 grams with a maximum of 1455 grams. Higher exerted forces were associated apnoea and bradycardia during the first 10 minutes of respiratory support at birth.


Subject(s)
Apnea , Infant, Premature , Infant, Newborn , Humans , Apnea/etiology , Masks/adverse effects , Bradycardia/etiology , Positive-Pressure Respiration
3.
Front Pediatr ; 11: 1273136, 2023.
Article in English | MEDLINE | ID: mdl-37876521

ABSTRACT

Introduction: The transition to newborn life has typically been studied in intubated and mechanically ventilated newborn lambs delivered via caesarean section (CS) under general anaesthesia. As a result, little is known of the spontaneous breathing patterns in lambs at birth, particularly those at risk of developing respiratory distress (RD). We have developed a method for delivering spontaneously breathing near-term lambs to characterise their breathing patterns in the immediate newborn period. Methods: At 137-8 days gestation (2-3 days prior to delivery; term ∼147 days), fetal lambs (n = 7) were partially exteriorised for instrumentation (insertion of catheters and flow probes) before they were returned to the uterus. At 140 days, lambs were delivered via CS under light maternal sedation and spinal anaesthesia. Lambs were physically stimulated and when continuous breathing was established, the umbilical cord was clamped. Breathing patterns were assessed by measuring intrapleural and upper-tracheal pressures during the first four hours after birth. Results: Newborn lambs display significant heterogeneity in respiratory patterns in the immediate newborn period that change with time after birth. Seven distinct breathing patterns were identified including: (i) quiet (tidal) breathing, (ii) breathing during active periods, (iii) breathing during oral feeding, (iv) tachypnoea, (v) expiratory braking manoeuvres, (vi) expiratory pauses or holding, and (vii) step changes in ventilation. Conclusions: We have described normal respiratory behaviour in newborn lambs, in order to identify respiratory behaviours that are indicative of RD in term newborn infants.

4.
Front Pediatr ; 11: 1148443, 2023.
Article in English | MEDLINE | ID: mdl-37284289

ABSTRACT

Background: Optimizing respiratory support after birth requires real-time feedback on lung aeration. We hypothesized that lung ultrasound (LUS) can accurately monitor the extent and progression of lung aeration after birth and is closely associated with oxygenation. Methods: Near-term (140 days gestation, term ∼147 days), spontaneously breathing lambs with normal (controls; n = 10) or elevated lung liquid levels (EL; n= 9) were delivered by Caesarean section and monitored for four hours after birth. LUS (Phillips CX50, L3-12 transducer) images and arterial blood gases were taken every 5-20 min. LUS images were analyzed both qualitatively (grading) and quantitatively (using the coefficient of variation of pixel intensity (CoV) to estimate the degree of lung aeration), which was correlated with the oxygen exchange capacity of the lungs (Alveolar-arterial difference in oxygen; AaDO2). Results: Lung aeration, measured using LUS, and the AaDO2 improved over the first 4 h after birth. The increase in lung aeration measured using CoV of pixel intensity, but not LUS grade, was significantly reduced in EL lambs compared to controls (p = 0.02). The gradual decrease in AaDO2 after birth was significantly correlated with increased lung aeration in both control (grade, r2 = 0.60, p < 0.0001; CoV, r2 = 0.54, p < 0.0001) and EL lambs (grade, r2 = 0.51, p < 0.0001; CoV, r2 = 0.44, p < 0.0001). Conclusions: LUS can monitor lung aeration and liquid clearance after birth in spontaneously breathing near-term lambs. Image analysis techniques (CoV) may be able detect small to moderate differences in lung aeration in conditions with lung liquid retention which are not readily identified using qualitative LUS grading.

5.
Phys Med Biol ; 67(20)2022 10 07.
Article in English | MEDLINE | ID: mdl-36126657

ABSTRACT

Objective. To develop a robust technique for calculating regional volume changes within the lung from x-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT).Approach. This technique is based on the change in transmitted x-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue.Main results. Lung air volumes calculated from x-ray intensity changes showed a strong correlation (R2= 0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from x-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT.Significance. This method is suitable for biomedical research studies,enabling quantitative regional measurement of relative lung air volumes at high temporal resolution, and shows great potential for future clinical application.


Subject(s)
Lung , Tomography, X-Ray Computed , Animals , Lung/diagnostic imaging , Lung Volume Measurements/methods , Rabbits , Radiography , Tomography, X-Ray Computed/methods , X-Rays
6.
Ultrasound Obstet Gynecol ; 57(2): 305-313, 2021 02.
Article in English | MEDLINE | ID: mdl-31765050

ABSTRACT

OBJECTIVE: Insufflation of the amniotic cavity with carbon dioxide (CO2 ) is used clinically to improve visibility during complex fetoscopic surgery. Insufflation with heated, humidified CO2 has recently been shown to reduce fetal hypercapnia and acidosis in sheep, compared with use of cold and dry CO2 , but the underlying mechanisms are unclear. The aim of this study was to investigate whether differences in placental CO2 and oxygen (O2 ) exchange during insufflation with heated and humidified vs cold and dry CO2 could explain these findings. METHODS: Thirteen fetal lambs at 105 days of gestation (term, 146 days) were exteriorized partially, via a midline laparotomy and hysterotomy, and instrumented with an umbilical artery catheter, an umbilical vein catheter and a common umbilical vein flow probe. Arterial and venous catheters and flow probes were also inserted into the maternal uterine circulation. Six ewes were insufflated with cold, dry CO2 (22°C; 0-5% humidity) and seven with heated, humidified CO2 (40°C; 95-100% humidity) at 15 mmHg for 180 min. Blood-flow recordings and paired arterial and venous blood gases were sampled from uterine and umbilical vessels. Rates of placental CO2 and O2 exchange were calculated. RESULTS: After 180 min of insufflation, fetal survival was 33% (2/6) using cold, dry CO2 and 71% (5/7) using heated, humidified CO2 . By 120 min, fetuses insufflated with heated, humidified CO2 had lower arterial CO2 levels and higher arterial pH compared to those insufflated with cold, dry gas. Insufflation decreased significantly placental gas exchange in both groups, as measured by rates of both (i) fetal CO2 clearance and O2 uptake and (ii) maternal O2 delivery and CO2 uptake from the fetal compartment. CONCLUSIONS: Lower arterial CO2 and higher pH levels in fetuses insufflated with heated and humidified, compared to cold and dry, CO2 could not be explained by differences in placental gas exchange. Instead, heated and humidified insufflation appeared to reduce fetal CO2 absorption from the uterus, supporting its use in preference to cold, dry CO2 . © 2019 International Society of Ultrasound in Obstetrics and Gynecology.


Subject(s)
Carbon Dioxide/administration & dosage , Insufflation , Placenta/metabolism , Animals , Blood Gas Analysis , Carbon Dioxide/metabolism , Female , Models, Animal , Pregnancy , Sheep
7.
Resuscitation ; 153: 71-78, 2020 08.
Article in English | MEDLINE | ID: mdl-32504770

ABSTRACT

AIM OF THE STUDY: Establishing functional residual capacity (FRC) during positive pressure ventilation (PPV) of apnoeic neonates is critical for survival. This may be difficult due to liquid-filled airways contributing to low lung compliance. The objectives were to describe initial PPV, changes in lung compliance and establishment of FRC in near-term/term neonates ≥36 weeks gestation at birth. METHODS: Observational study of all neonatal resuscitations between 01.07.13 and 30.06.18 in a Tanzanian referral hospital. Perinatal events and characteristics were observed and recorded by trained research assistants. PPV were performed using self-inflating bag-masks without positive end-expiratory pressure (PEEP). Ventilation signals (pressure/flow), expired CO2 (ECO2) and heart rate were recorded by resuscitation monitors. RESULTS: 19,587 neonates were born, 1451 received PPV, of these 821 of median (p25, p75) birthweight 3180 (2844, 3500) grams and gestation 38 (37, 40) weeks had ≥20 ventilations and complete datasets. There was a significant increase in expired volume (from 3.3 to 6.0 ml/kg), ECO2 (0.3-2.4%), lung compliance (0.13-0.19 ml/kg/mbar) and heart rate (109-138 beats/min) over the first 20 PPVs. Inflation volume, time, and peak inflation pressure (PIP) were stable around 12-13 ml/kg, 0.45 s, and 36 mbar, respectively. CONCLUSIONS: The combination of increasing expired volumes, ECO2, and heart rate with decreasing inflation/expired volume ratios and constant PIP, suggests establishment of FRC during the first 20 PPVs in near-term/term neonates using a self-inflating bag-mask without PEEP, the most common device worldwide for ventilating non-breathing neonates. Initial lung compliance is low, and with short inflation times, higher than recommended PIP seem necessary to deliver adequate tidal volumes.


Subject(s)
Insufflation , Resuscitation , Functional Residual Capacity , Humans , Infant, Newborn , Positive-Pressure Respiration , Tidal Volume
8.
Ultrasound Obstet Gynecol ; 54(4): 506-516, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31364206

ABSTRACT

OBJECTIVES: Infants with congenital diaphragmatic hernia (CDH) are predisposed to pulmonary hypertension after birth, owing to lung hypoplasia that impairs fetal pulmonary vascular development. Antenatal sildenafil treatment attenuates abnormal pulmonary vascular and alveolar development in rabbit and rodent CDH models, but whether this translates to functional improvements after birth remains unknown. We aimed to evaluate the effect of antenatal sildenafil on neonatal pulmonary hemodynamics and lung function in lambs with diaphragmatic hernia (DH). METHODS: DH was surgically induced at approximately 80 days' gestation in 16 lamb fetuses (term in lambs is approximately 147 days). From 105 days' gestation, ewes received either sildenafil (0.21 mg/kg/h intravenously) or saline infusion until delivery (n = 8 fetuses in each group). At approximately 138 days' gestation, all lambs were instrumented and then delivered via Cesarean section. The lambs were ventilated for 120 min with continuous recording of physiological (pulmonary and carotid artery blood flow and pressure; cerebral oxygenation) and ventilatory parameters, and regular assessment of arterial blood gas tensions. Only lambs that survived until delivery and with a confirmed diaphragmatic defect at postmortem examination were included in the analysis; these comprised six DH-sildenafil lambs and six DH-saline control lambs. RESULTS: Lung-to-body-weight ratio (0.016 ± 0.001 vs 0.013 ± 0.001; P = 0.06) and dynamic lung compliance (0.8 ± 0.2 vs 0.7 ± 0.2 mL/cmH2 O; P = 0.72) were similar in DH-sildenafil lambs and controls. Pulmonary vascular resistance decreased following lung aeration to a greater degree in DH-sildenafil lambs, and was 4-fold lower by 120 min after cord clamping than in controls (0.6 ± 0.1 vs 2.2 ± 0.6 mmHg/(mL/min); P = 0.002). Pulmonary arterial pressure was also lower (46 ± 2 vs 59 ± 2 mmHg; P = 0.048) and pulmonary blood flow higher (25 ± 3 vs 8 ± 2 mL/min/kg; P = 0.02) in DH-sildenafil than in DH-saline lambs at 120 min. Throughout the 120-min ventilation period, the partial pressure of arterial carbon dioxide tended to be lower in DH-sildenafil lambs than in controls (63 ± 8 vs 87 ± 8 mmHg; P = 0.057), and there was no significant difference in partial pressure of arterial oxygen between the two groups. CONCLUSIONS: Sustained maternal antenatal sildenafil infusion reduced pulmonary arterial pressure and increased pulmonary blood flow in DH lambs for the first 120 min after birth. These findings of improved pulmonary vascular function are consistent with improved pulmonary vascular structure seen in two previous animal models. The data support the rationale for a clinical trial investigating the effect of antenatal sildenafil in reducing the risk of neonatal pulmonary hypertension in infants with CDH. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Subject(s)
Hemodynamics/drug effects , Hernias, Diaphragmatic, Congenital/drug therapy , Lung/drug effects , Phosphodiesterase 5 Inhibitors/pharmacology , Sildenafil Citrate/pharmacology , Animals , Autopsy/methods , Blood Gas Analysis/methods , Female , Fetal Therapies/methods , Fetus , Hernias, Diaphragmatic, Congenital/physiopathology , Lung/blood supply , Lung/physiopathology , Models, Animal , Phosphodiesterase 5 Inhibitors/administration & dosage , Phosphodiesterase 5 Inhibitors/blood , Pregnancy , Prenatal Care , Pulmonary Gas Exchange/drug effects , Sheep , Sildenafil Citrate/administration & dosage , Sildenafil Citrate/blood
9.
Resuscitation ; 136: 100-104, 2019 03.
Article in English | MEDLINE | ID: mdl-30708072

ABSTRACT

AIM: To determine the time between adjustment of FiO2 at the oxygen blender and the desired FiO2 reaching the preterm infant during respiratory support at birth. METHODS: This observational study was performed using a Neopuff™ T-piece Resuscitator attached to either a test lung (during initial bench tests) or a face mask during the stabilization of infants at birth. FiO2 was titrated following resuscitation guidelines. The duration for the desired FiO2 to reach either the test lung or face mask was recorded, both with and without leakage. A respiratory function monitor was used to record FiO2 and amount of leak. RESULTS: In bench tests, the median (IQR) time taken to achieve a desired FiO2 was 34.2 (21.8-69.1) s. This duration was positively associated with the desired FiO2 difference, the direction of titration (upwards) and the occurrence of no leak (R2 0.863, F 65.016, p < 0.001). During stabilization of infants (median (IQR) gestational age 29+0 (28+2-30+0) weeks, birthweight 1290 (1240-1488) g), the duration (19.0 (0.0-57.0) s) required to reach a desired FiO2 was less, but still evident. In 27/55 (49%) titrations, the desired FiO2 was not achieved before the FiO2 levels were again changed. CONCLUSION: There is a clear delay before a desired FiO2 is achieved at the distal end of the T-piece resuscitator. This delay is clinically relevant as this delay could easily lead to over- and under titration of oxygen, which might result in an increased risk for both hypoxia and hyperoxia.


Subject(s)
Oxygen Consumption/physiology , Positive-Pressure Respiration/methods , Resuscitation/methods , Humans , Hyperoxia/prevention & control , Hypoxia/prevention & control , Infant, Newborn , Infant, Premature , Infant, Very Low Birth Weight , Intensive Care, Neonatal , Linear Models , Time Factors
10.
Ultrasound Obstet Gynecol ; 53(3): 340-347, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30461102

ABSTRACT

OBJECTIVE: Partial amniotic carbon dioxide (CO2 ) insufflation (PACI) is used to improve visualization and facilitate complex fetoscopic surgery. However, there are concerns about fetal hypercapnic acidosis and postoperative fetal membrane inflammation. We assessed whether using heated and humidified, rather than cold and dry, CO2 might reduce the impact of PACI on the fetus and fetal membranes in sheep. METHODS: Twelve fetal lambs of 105 days' gestational age (term = 145 days) were exteriorized partially, via a midline laparotomy and hysterotomy, and arterial catheters and flow probes were inserted surgically. The 10 surviving fetuses were returned to the uterus, which was then closed and insufflated with cold, dry (22 °C at 0-5% humidity, n = 5) or heated, humidified (40 °C at 100% humidity, n = 5) CO2 at 15 mmHg for 180 min. Fetal membranes were collected immediately after insufflation for histological analysis. Physiological data and membrane leukocyte counts, suggestive of membrane inflammation, were compared between the two groups. RESULTS: After 180 min of insufflation, fetal survival was 0% in the group which underwent PACI with cold, dry CO2 , and 60% (n = 3) in the group which received heated, humidified gas. While all insufflated fetuses became progressively hypercapnic (PaCO2  > 68 mmHg), this was considerably less pronounced in those in which heated, humidified gas was used: after 120 min of insufflation, compared with those receiving cold, dry gas (n = 3), fetuses undergoing heated, humidified PACI (n = 5) had lower arterial partial pressure of CO2 (mean ± standard error of the mean, 82.7 ± 9.1 mmHg for heated, humidified CO2 vs 170.5 ± 28.5 for cold, dry CO2 during PACI, P < 0.01), lower lactate levels (1.4 ± 0.4 vs 8.5 ± 0.9 mmol/L, P < 0.01) and higher pH (pH, 7.10 ± 0.04 vs 6.75 ± 0.04, P < 0.01). There was also a non-significant trend for fetal carotid artery pressure to be higher following PACI with heated, humidified compared with cold, dry CO2 (30.5 ± 1.3 vs 8.7 ± 5.5 mmHg, P = 0.22). Additionally, the median (interquartile range) number of leukocytes in the chorion was significantly lower in the group undergoing PACI with heated, humidified CO2 compared with the group receiving cold, dry CO2 (0.7 × 10-5 (0.5 × 10-5 ) vs 3.2 × 10-5 (1.8 × 10-5 ) cells per square micron, P = 0.02). CONCLUSIONS: PACI with cold, dry CO2 causes hypercapnia, acidosis, hypotension and fetal membrane inflammation in fetal sheep, raising potential concerns for its use in humans. It seems that using heated, humidified CO2 for insufflation partially mitigates these effects and this may be a suitable alternative for reducing the risk of fetal acid-base disturbances during, and fetal membrane inflammation following, complex fetoscopic surgery. © 2018 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Subject(s)
Insufflation , Meningomyelocele , Animals , Carbon Dioxide , Female , Fetoscopy , Humans , Models, Animal , Pregnancy , Sheep , Uterus
11.
J Dev Orig Health Dis ; 8(5): 556-565, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28789711

ABSTRACT

Fetal growth restriction (FGR) and preterm birth are frequent co-morbidities, both are independent risks for brain injury. However, few studies have examined the mechanisms by which preterm FGR increases the risk of adverse neurological outcomes. We aimed to determine the effects of prematurity and mechanical ventilation (VENT) on the brain of FGR and appropriately grown (AG, control) lambs. We hypothesized that FGR preterm lambs are more vulnerable to ventilation-induced acute brain injury. FGR was surgically induced in fetal sheep (0.7 gestation) by ligation of a single umbilical artery. After 4 weeks, preterm lambs were euthanized at delivery or delivered and ventilated for 2 h before euthanasia. Brains and cerebrospinal fluid (CSF) were collected for analysis of molecular and structural indices of early brain injury. FGRVENT lambs had increased oxidative cell damage and brain injury marker S100B levels compared with all other groups. Mechanical ventilation increased inflammatory marker IL-8 within the brain of FGRVENT and AGVENT lambs. Abnormalities in the neurovascular unit and increased blood-brain barrier permeability were observed in FGRVENT lambs, as well as an altered density of vascular tight junctions markers. FGR and AG preterm lambs have different responses to acute injurious mechanical ventilation, changes which appear to have been developmentally programmed in utero.


Subject(s)
Brain Injuries/pathology , Brain Injuries/physiopathology , Fetal Growth Retardation/pathology , Fetal Growth Retardation/physiopathology , Health Status , Respiration, Artificial/adverse effects , Animals , Animals, Newborn , Brain Injuries/etiology , Female , Forecasting , Sheep
12.
J Appl Physiol (1985) ; 122(3): 503-510, 2017 Mar 01.
Article in English | MEDLINE | ID: mdl-28035014

ABSTRACT

Detailed information on the distribution of airway diameters during bronchoconstriction in situ is required to understand the regional response of the lungs. Imaging studies using computed tomography (CT) have previously measured airway diameters and changes in response to bronchoconstricting agents, but the manual measurements used have severely limited the number of airways measured per subject. Hence, the detailed distribution and heterogeneity of airway responses are unknown. We have developed and applied dynamic imaging and advanced image-processing methods to quantify and compare hundreds of airways in vivo. The method, based on CT, was applied to house dust-mite-sensitized and control mice during intravenous methacholine (MCh) infusion. Airway diameters were measured pre- and post-MCh challenge, and the results compared demonstrate the distribution of airway response throughout the lungs during mechanical ventilation. Forced oscillation testing was used to measure the global response in lung mechanics. We found marked heterogeneity in the response, with paradoxical dilation of airways present at all airway sizes. The probability of paradoxical dilation decreased with decreasing baseline airway diameter and was not affected by pre-existing inflammation. The results confirm the importance of considering the lung as an entire interconnected system rather than a collection of independent units. It is hoped that the response distribution measurements can help to elucidate the mechanisms that lead to heterogeneous airway response in vivo.NEW & NOTEWORTHY Information on the distribution of airway diameters during bronchoconstriction in situ is critical for understanding the regional response of the lungs. We have developed an imaging method to quantify and compare the size of hundreds of airways in vivo during bronchoconstriction in mice. The results demonstrate large heterogeneity with both constriction and paradoxical dilation of airways, confirming the importance of considering the lung as an interconnected system rather than a collection of independent units.


Subject(s)
Airway Resistance/drug effects , Bronchi/pathology , Bronchi/physiopathology , Bronchial Provocation Tests , Bronchoconstriction/drug effects , Methacholine Chloride/pharmacology , Animals , Bronchi/drug effects , Bronchoconstrictor Agents/pharmacology , Image Interpretation, Computer-Assisted , Male , Mice , Mice, Inbred C57BL , Pattern Recognition, Automated , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed
13.
Arch Dis Child Fetal Neonatal Ed ; 100(4): F337-43, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25922189

ABSTRACT

OBJECTIVE: At birth, an initial sustained inflation (SI) uniformly aerates the lungs, increases arterial oxygenation and rapidly improves circulatory recovery in asphyxiated newborns. We hypothesised that lung aeration, in the absence of an increase in arterial oxygenation, can increase heart rate (HR) in asphyxiated near-term lambs. INTERVENTIONS: Lambs were delivered and instrumented at 139±2 days of gestation. Asphyxia was induced by umbilical cord clamping and then delaying the onset of ventilation until mean carotid arterial pressures (CAPs) had decreased <20 mm Hg. Lambs then received a single 30-s SI using nitrogen (N2; n=6), 5% oxygen (O2; n=6), 21% O2 (n=6) or 100% O2 (n=6) followed by ventilation in air for 30 min. MAIN OUTCOME MEASURES: HR, CAP and pulmonary blood flow (PBF) were continuously recorded. RESULTS: HR and PBF increased more quickly in lambs resuscitated with 100% and 21% O2 than with 5% O2 or N2. HR and PBF recovery in the 5% O2 group was delayed relative to all other oxygen SI groups. HR in 5%, 21% and 100% O2 groups reached 100 bpm before the SI was complete. HR and PBF in the N2 group did not increase until 10 s after the SI was completed and ventilation was initiated with air. CAP tended to increase quicker in all O2 groups than in N2 group. CONCLUSIONS: Oxygen content during an SI is important for circulatory recovery in asphyxiated lambs. This increase in HR is likely driven by the increase in PBF and venous return to the heart.


Subject(s)
Asphyxia Neonatorum , Blood Pressure , Heart Rate , Insufflation/methods , Lung , Oxygen/therapeutic use , Animals , Animals, Newborn , Asphyxia Neonatorum/blood , Asphyxia Neonatorum/physiopathology , Asphyxia Neonatorum/therapy , Blood Gas Analysis , Disease Models, Animal , Humans , Infant, Newborn , Lung/blood supply , Lung/physiopathology , Recovery of Function/physiology , Respiratory Function Tests/methods , Sheep , Sheep, Domestic
14.
Arch Dis Child Fetal Neonatal Ed ; 100(2): F121-5, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25389141

ABSTRACT

BACKGROUND: Delayed umbilical cord clamping (DCC) affects the cardiopulmonary transition and blood volume in neonates immediately after birth. However, little is known of blood flow in the umbilical vessels immediately after birth during DCC. The objective is to describe the duration and patterns of blood flow through the umbilical vessels during DCC. METHODS: Arterial and venous umbilical blood flow was measured during DCC using Doppler ultrasound in uncomplicated term vaginal deliveries. Immediately after birth, the probe was placed in the middle of the umbilical cord, pattern and duration of flow in vein and arteries were evaluated until cord clamping. RESULTS: Thirty infants were studied. Venous flow: In 10% no flow was present, in 57% flow stopped at 4:34 (3:03-7:31) (median (IQR) min:sec) after birth, before the cord was clamped. In 33%, flow continued until cord clamping at 5:13 (2:56-9:15) min:sec. Initially, venous flow was intermittent, increasing markedly during large breaths or stopping and reversing during crying, but then became continuous. Arterial flow: In 17% no flow was present, in 40% flow stopped at 4:22 (2:29-7:17) min:sec, while cord pulsations were still palpable. In 43% flow continued until the cord was clamped at 5:16 (3:32-10:10) min:sec. Arterial flow was pulsatile, unidirectional towards placenta or bidirectional to/from placenta. In 40% flow became continuous towards placenta later on. CONCLUSIONS: During delayed umbilical cord clamping, venous and arterial umbilical flow occurs for longer than previously described. Net placental transfusion is probably the result of several factors of which breathing could play a major role. Umbilical flow is unrelated to cessation of pulsations.


Subject(s)
Delivery, Obstetric/methods , Umbilical Cord/blood supply , Apgar Score , Birth Weight , Constriction , Female , Gestational Age , Humans , Infant, Newborn , Male , Pilot Projects , Placental Circulation/physiology , Pregnancy , Prospective Studies , Pulsatile Flow/physiology , Ultrasonography, Doppler/methods , Umbilical Arteries/diagnostic imaging , Umbilical Arteries/physiology , Umbilical Cord/diagnostic imaging , Umbilical Veins/diagnostic imaging , Umbilical Veins/physiology
15.
Arch Dis Child Fetal Neonatal Ed ; 99(4): F278-81, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24596406

ABSTRACT

BACKGROUND: Administration of oxygen in the delivery room is informed by oxygen saturation (SpO2). An oxygen saturation range of 60%-70% is the threshold for administering oxygen in the first minutes after birth. The accuracy of newer generation oximeters to measure SpO2 has not been compared against the 'gold standard', direct arterial blood oxygen saturation (SaO2) when SaO2 is low. The aim of this study was to determine the accuracy and precision of Nellcor and Masimo oximeters to measure SpO2 when SaO2 <70%. METHOD: Prospective observational study in ventilated anaesthetised newborn lambs with an indwelling carotid artery catheter. Ventilation was adjusted to achieve hypoxaemia. Nellcor (Oxi-Max 600 with Max-N sensor) and Masimo (Rad 4 with low noise optical probe (LNOP) sensor) sensors were applied to the right forelimb (preductal). An arterial blood sample was collected at 1-5 min intervals when the animal was hypoxic. The displayed SpO2 was recorded. We used Bland-Altman analysis to determine precision and accuracy of each oximeter when SaO2 <70%. RESULTS: 17 lambs were studied, 165 measurements were obtained, 123 were SaO2 <70%. The mean difference (±1.96 SD) Nellcor SpO2-SaO2 when SaO2 <70% was 17% (-12% to 46%). The mean difference (±1.96 SD) Masimo SpO2-SaO2 when SaO2 <70% was 13% (-19% to 45%). CONCLUSIONS: At SaO2<70%, both monitors overestimated oxygen saturation (SpO2) compared with the gold standard. Both oximeters were equally inaccurate when SaO2 was low.


Subject(s)
Hypoxia/diagnosis , Oximetry/instrumentation , Oxygen/blood , Animals , Animals, Newborn , Disease Models, Animal , Hypoxia/blood , Hypoxia/therapy , Oximetry/methods , Oximetry/standards , Oxygen Inhalation Therapy , Reproducibility of Results , Sheep, Domestic
16.
Arch Dis Child Fetal Neonatal Ed ; 99(4): F274-7, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24646620

ABSTRACT

OBJECTIVE: In neonatal resuscitation, the use of a sustained inflation (SI) may facilitate lung aeration. Previous studies comparing different resuscitation devices have shown that one model of self-inflating bag (SIB) could not deliver an SI. We aimed to compare the delivery of an SI using four SIBs with that of a T-piece. STUDY DESIGN: In intubated preterm lambs, we compared four models of SIB fitted with a positive end expiratory pressure (PEEP) valve to a T-piece using a gas flow of 8 L/min. Four operators aimed to deliver three SIs of 20 cm H2O for 30 s. The study was repeated with the PEEP valve removed and again with no flow. We measured duration of SI, average inflation pressure (IP) and analysed the shape of the pressure curves. RESULTS: 204 combinations were analysed. Mean (SD) duration of SI was Ambu 6(2)s, Laerdal 14(8)s, Parker Healthcare 5(1)s, Mayo Healthcare 33(2)s and T-piece 33(1)s. Mean (SD) average IP was Ambu 17(3)cm H2O, Laerdal 17(3)cm H2O, Parker Healthcare 12(5)cm H2O, Mayo Healthcare 21(2)cm H2O and T-piece 20(0)cm H2O. Duration of SI and average IP was significantly different between SIBs (all p<0.001). The findings were substantially unchanged when PEEP valve and flow were removed (all p>0.05). Only the Mayo system delivered SIs with duration and average IP not significantly different from the T-piece (p>0.05). CONCLUSIONS: The performance of the four SIBs tested varied considerably. Some are able to deliver an SI even in the absence of gas flow. This may be useful in a resource-limited setting with no gas supply.


Subject(s)
Positive-Pressure Respiration/instrumentation , Resuscitation/instrumentation , Animals , Animals, Newborn , Disposable Equipment , Equipment Design , Female , Insufflation/instrumentation , Insufflation/methods , Models, Animal , Positive-Pressure Respiration/methods , Pregnancy , Premature Birth , Resuscitation/methods , Sheep, Domestic
17.
J Perinatol ; 32(2): 111-6, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21637192

ABSTRACT

OBJECTIVE: The objective of this study is to compare the effects of back-up ventilation rates (BURs) on triggered inflations and patient cardiorespiratory stability during assist-control/volume guarantee ventilation (AC/VG). STUDY DESIGN: This study is a randomized crossover trial conducted in a neonatal unit in an Australian tertiary NICU. In all, 26 stable preterm infants on AC/VG ventilation were studied at BUR settings of 30, 40 and 50 min(-1). Inflation rate, triggering and cardiorespiratory measures of patient stability were compared during 20 min epochs with 10 min washout periods. RESULT: The 26 infants studied were median (inter-quartile range) gestational age 27 (26, 30) weeks, birth weight 0.84 (0.75, 1.14) kg and FiO(2) 0.24 (0.21, 0.31) and age 6 (4, 19) days. At BURs of 30, 40 and 50, the proportions of inflations, which were triggered, were mean (s.d.) 85% (11), 75% (19) and 61% (25); P<0.01 for all comparisons. Total delivered inflation rates were 56 (8), 58 (9) and 62 (8) min(-1), respectively. Cardiorespiratory parameters did not vary between the settings. CONCLUSION: Using a lower BUR allows greater triggering of ventilator inflations. Cardiorespiratory parameters including CO(2) levels were stable at all rates.


Subject(s)
Infant, Premature , Respiration, Artificial/instrumentation , Respiratory Insufficiency/therapy , Tidal Volume/physiology , Australia , Birth Weight , Cross-Over Studies , Female , Follow-Up Studies , Gestational Age , Humans , Infant, Newborn , Intensive Care Units, Neonatal , Male , Pulmonary Gas Exchange , Respiration, Artificial/methods , Respiratory Insufficiency/diagnosis , Respiratory Mechanics , Risk Assessment , Time Factors , Treatment Outcome , Ventilator Weaning , Ventilators, Mechanical/statistics & numerical data
18.
Phys Med Biol ; 56(23): 7353-69, 2011 Dec 07.
Article in English | MEDLINE | ID: mdl-22048612

ABSTRACT

We demonstrate interface-specific propagation-based x-ray phase retrieval tomography of the thorax and brain of small animals. Our method utilizes a single propagation-based x-ray phase-contrast image per projection, under the assumptions of (i) partially coherent paraxial radiation, (ii) a static object whose refractive indices take on one of a series of distinct values at each point in space and (iii) the projection approximation. For the biological samples used here, there was a 9-200 fold improvement in the signal-to-noise ratio of the phase-retrieved tomograms over the conventional attenuation-contrast signal. The ability to 'digitally dissect' a biological specimen, using only a single phase-contrast image per projection, will be useful for low-dose high-spatial-resolution biomedical imaging of form and biological function in both healthy and diseased tissue.


Subject(s)
Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Animals , Brain/diagnostic imaging , Female , Pregnancy , Rabbits , Radiography, Thoracic , Rats , Signal-To-Noise Ratio
19.
J Appl Physiol (1985) ; 111(3): 775-81, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21719723

ABSTRACT

Perinatal inflammation is associated with adverse neurodevelopmental outcomes, which may be partly due to changes in the cerebral oxygen delivery/consumption relationship. We aimed to determine the critical oxygen delivery threshold of the brain of preterm, ventilated lambs and to determine whether the critical threshold is affected by exposure to inflammation in utero. Pregnant ewes received intra-amniotic injection of lipopolysaccharide or saline at 125 or 127 days of gestation. Pulmonary and systemic flow probes and catheters were surgically positioned in the fetus immediately before delivery at 129 days of gestation. After delivery, lambs were ventilated for 90 min using a positive end-expiratory pressure recruitment strategy. Cardio-respiratory variables and blood gases were measured regularly. Systemic and cerebral oxygen delivery, consumption (Fick), and extraction were calculated, and the relationship between cerebral delivery and consumption analyzed. Linear regression was used to define the transition or "critical" oxygen threshold as the point at which the slope of the oxygen delivery/consumption curve changed to be > 10°. Four subgroups were defined according to the calculated critical threshold. A total of 150 measurements were recorded in 18 lambs. Fetal cerebral oxygen consumption was increased by antenatal lipopolysaccharide (P < 0.05). The postnatal critical oxygen threshold was 3.6 ml·kg⁻¹·min⁻¹, corresponding to cerebral oxygen consumption of 0.73 ml·kg⁻¹·min⁻¹. High oxygen delivery and consumption were associated with increased pulmonary and carotid blood flow and systemic extraction compared with low oxygen delivery and consumption. No postnatal effect of antenatal inflammation was observed. Inflammation in utero increases fetal, but not postnatal, cerebral oxygen consumption. Adverse alterations to pulmonary blood flow can result in reduced cerebral blood flow, oxygen delivery, and consumption. Regardless of exposure to inflammation, there is a consistent postnatal relationship between cerebral oxygen delivery and consumption.


Subject(s)
Brain/metabolism , Chorioamnionitis/metabolism , Hypoxia-Ischemia, Brain/etiology , Inflammation/metabolism , Oxygen Consumption , Oxygen/metabolism , Premature Birth , Respiration, Artificial , Animals , Brain/blood supply , Brain/immunology , Carotid Arteries/physiopathology , Cerebrovascular Circulation , Chorioamnionitis/chemically induced , Chorioamnionitis/immunology , Chorioamnionitis/physiopathology , Disease Models, Animal , Female , Gestational Age , Hypoxia-Ischemia, Brain/immunology , Hypoxia-Ischemia, Brain/metabolism , Hypoxia-Ischemia, Brain/physiopathology , Inflammation/chemically induced , Inflammation/complications , Inflammation/immunology , Inflammation/physiopathology , Kinetics , Lipopolysaccharides , Oxygen/blood , Pregnancy , Pulmonary Circulation , Regional Blood Flow , Respiration, Artificial/adverse effects , Sheep
20.
Arch Dis Child Fetal Neonatal Ed ; 95(3): F177-81, 2010 May.
Article in English | MEDLINE | ID: mdl-20444810

ABSTRACT

The normal range of heart rate (HR) in the first minutes after birth has not been defined. Objective To describe the HR changes of healthy newborn infants in the delivery room (DR) detected by pulse oximetry. Study Design All inborn infants were eligible and included if a member of the research team attended the birth. Infants were excluded if they received any form of medical intervention in the DR including supplemental oxygen, or respiratory support. HR was measured using a pulse oximeter (PO) with the sensor applied to the right hand or wrist immediately after birth. PO data (oxygen saturation, HR and signal quality) were downloaded every 2 sec and analysed only when the signal had no alarm messages (low IQ signal, low perfusion, sensor off, ambient light). Results Data from 468 infants with 61 650 data points were included. Infants had a mean (range) gestational age of 38 (25-42) weeks and birth weight 2970 (625-5135) g. At 1 min the median (IQR) HR was 96 (65-127) beats per min (bpm) rising at 2 min and 5 min to 139 (110-166) bpm and 163 (146-175) bpm respectively. In preterm infants, the HR rose more slowly than term infants. Conclusions The median HR was <100 bpm at 1 min after birth. After 2 min it was uncommon to have a HR <100 bpm. In preterm infants and those born by caesarean section the HR rose more slowly than term vaginal births.


Subject(s)
Heart Rate/physiology , Infant, Newborn/physiology , Anesthesia, Obstetrical/methods , Birth Weight/physiology , Cesarean Section , Delivery, Obstetric/methods , Female , Gestational Age , Humans , Infant, Premature/physiology , Oximetry/methods , Postoperative Period , Pregnancy , Reference Values
SELECTION OF CITATIONS