Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Tech Vasc Interv Radiol ; 26(4): 100928, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38123286

ABSTRACT

Orthotopic heart transplantation is a life-saving procedure that has substantially improved the lives of countless patients since its inception. However, there are several procedure-related complications that require prompt management. Interventional radiology, with its ever expanding toolkit, is a cornerstone of the multidisciplinary team following post-cardiac transplant patients. Percutaneous, endovascular therapy provides minimally invasive, safe, and effective treatments for immediate and delayed cardiac transplant complications and this paper serves to highlight the various management options interventional radiology can provide for orthotopic heart transplantation complications.


Subject(s)
Heart Transplantation , Liver Transplantation , Humans , Liver Transplantation/methods , Radiology, Interventional , Treatment Outcome , Heart Transplantation/adverse effects
2.
CVIR Endovasc ; 6(1): 55, 2023 Nov 11.
Article in English | MEDLINE | ID: mdl-37950835

ABSTRACT

BACKGROUND: Endobronchial forceps are commonly used for complex IVC filter removal and after initial attempts at IVC filter retrieval with a snare have failed. Currently, there are no clear guidelines to help distinguish cases where primary removal should be attempted with standard snare technique or whether attempts at removal should directly be started with forceps. This study is aimed to identify clinical and imaging predictors of snare failure which necessitate conversion to endobronchial forceps. METHODS: Retrospective analysis of 543 patients who underwent IVC filter retrievals were performed at three large quaternary care centers from Jan 2015 to Jan 2022. Patient demographics and IVC filter characteristics on cross-sectional images (degree of tilt, hook embedment, and strut penetration, etc.) were reviewed. Binary multivariate logistic regression was used to identify predictors of IVC filter retrieval where snare retrieval would fail. RESULTS: Thirty seven percent of the patients (n = 203) necessitated utilization of endobronchial forceps. IVC filter hook embedment (OR:4.55; 95%CI: 1.74-11.87; p = 0.002) and strut penetration (OR: 56.46; 95% CI 20.2-157.7; p = 0.001) were predictors of snare failure. In contrast, total dwell time, BMI, and degree of filter tilt were not associated with snare failure. Intraprocedural conversion from snare to endobronchial forceps was significantly associated with increased contrast volume, radiation dose, and total procedure times (p < 0.05). CONCLUSION: IVC filter hook embedment and strut penetration were predictors of snare retrieval failure. Intraprocedural conversion from snare to endobronchial forceps increased contrast volume, radiation dose, and total procedure time. When either hook embedment or strut penetration is present on pre-procedural cross-sectional images, IVC filter retrieval should be initiated using endobronchial forceps. LEVEL OF EVIDENCE: Level 3, large multicenter retrospective cohort.

3.
CVIR Endovasc ; 6(1): 24, 2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37074479

ABSTRACT

BACKGROUND: Transjugular intrahepatic portosystemic shunt (TIPS) creation remains as one of the more technically challenging endovascular procedures. Portal vein access from the hepatic vein often requires multiple needle passes, which increases procedure times, risk of complications, and radiation exposure. With its bi-directional maneuverability, the Scorpion X access kit may be a promising tool for easier portal vein access. However, the clinical safety and feasibility of this access kit has yet to be determined. MATERIALS AND METHODS: In this retrospective study, 17 patients (12 male, average age 56.6 ± 9.01) underwent TIPS procedure using Scorpion X portal vein access kits. The primary endpoint was time taken to access the portal vein from the hepatic vein. The most common indications for TIPS were refractory ascites (47.1%) and esophageal varices (17.6%). Radiation exposure, total number of needle passes, and intraoperative complications were recorded. Average MELD Score was 12.6 ± 3.39 (range: 8-20). RESULTS: Portal vein cannulation was successfully achieved in 100% of patients during intracardiac echocardiography-assisted TIPS creation. Total fluoroscopy time was 39.31 ± 17.97 min; average radiation dose was 1036.76 ± 644.15 mGy, while average contrast dose was 120.59 ± 56.87 mL. The average number of passes from the hepatic vein to the portal vein was 2 (range: 1-6). Average time to access the portal vein once the TIPS cannula was positioned in the hepatic vein was 30.65 ± 18.64 min. There were no intraoperative complications. CONCLUSIONS: Clinical utilization of the Scorpion X bi-directional portal vein access kit is both safe and feasible. Utilizing this bi-directional access kit resulted in successful portal vein access with minimal intraoperative complications. LEVEL OF EVIDENCE: Retrospective cohort.

4.
Life (Basel) ; 13(2)2023 Jan 19.
Article in English | MEDLINE | ID: mdl-36836638

ABSTRACT

Hepatectomy remains the gold standard for curative therapy for patients with limited primary or metastatic hepatic tumors as it offers the best survival rates. In recent years, the indication for partial hepatectomy has evolved away from what will be removed from the patient to the volume and function of the future liver remnant (FLR), i.e., what will remain. With this regard, liver regeneration strategies have become paramount in transforming patients who previously had poor prognoses into ones who, after major hepatic resection with negative margins, have had their risk of post-hepatectomy liver failure minimized. Preoperative portal vein embolization (PVE) via the purposeful occlusion of select portal vein branches to promote contralateral hepatic lobar hypertrophy has become the accepted standard for liver regeneration. Advances in embolic materials, selection of treatment approaches, and PVE with hepatic venous deprivation or concurrent transcatheter arterial embolization/radioembolization are all active areas of research. To date, the optimal combination of embolic material to maximize FLR growth is not yet known. Knowledge of hepatic segmentation and portal venous anatomy is essential before performing PVE. In addition, the indications for PVE, the methods for assessing hepatic lobar hypertrophy, and the possible complications of PVE need to be fully understood before undertaking the procedure. The goal of this article is to discuss the rationale, indications, techniques, and outcomes of PVE before major hepatectomy.

5.
CVIR Endovasc ; 5(1): 39, 2022 Aug 06.
Article in English | MEDLINE | ID: mdl-35932376

ABSTRACT

BACKGROUND: Inferior vena cava (IVC) filter retrieval is typically accomplished with standard snare technique. When this fails, more advanced techniques are necessary, especially when removal falls outside a 12-month window. Complications during filter retrieval depend heavily on technique, type of filter, and filter position. In this study we examined safety and efficacy of 536 filter retrievals at a tertiary care center and compared complication rates between standard snare and endobronchial forcep retrieval. METHOD: We reviewed 536 cases between August 2015 and August 2020, recording retrieval success rates, patient comorbidities, and complication rates at the time of removal. RESULTS: Total overall retrieval success was 97.9% (525/536), and complications occurred in approximately 6.0% (32/536) of all cases. Success and complications with standard snare technique alone were 99.4% (345/347) and 1.7% (5 Grade I/II, 1 Grade III) and advanced forcep technique 98.8% (171/173) and 14.5% (22 Grade I/II, 2 Grade III, and 1 Grade IV), respectively. There was no significant difference between the technical success rates of the standard snare technique and forceps techniques (p = 0.60) despite a significantly longer dwell time in patients undergoing forceps retrieval (p < 0.001). CONCLUSION: To our knowledge, this is the largest cohort of forceps directed IVC filter retrieval present in the literature. Rates of successful endobronchial forceps and standard snare retrievals in this study are similar to previous reports. Although use of endobronchial forceps may be associated with higher complication rates, this is likely due to prolonged dwell times, filter tilt, and attempted removal of non retrievable filters. Overall, forceps-directed retrieval offers a safe, effective means of removal in difficult cases. LEVEL OF EVIDENCE: Level 3, Large Retrospective Study.

6.
Radiol Case Rep ; 15(11): 2319-2321, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32983306

ABSTRACT

We report a case of a uterine artery pseudoaneurysm in a 29-year-old primigravid woman at 16 weeks gestation. The woman presented to the emergency room with lower left quadrant pain and vaginal bleeding. Ultrasound revealed a left adnexal mass consistent with a pseudoaneurysm. Percutaneous thrombin injection was chosen to avoid contrast and radiation risks to the fetus. Ultrasound demonstrated thrombosis of the pseudoaneurysm with no evidence of fetal distress. On postprocedure day 2, the patient presented again with similar complaints of lower quadrant pain and vaginal bleeding. The pseudoaneurysm was found to have recanalized and a decision was made to treat with computed tomography angiography and coil embolization. The procedure was successful, with angiography revealing an incidental branch of the pseudoaneurysm that was subsequently embolized.

8.
Radiol Case Rep ; 14(11): 1432-1437, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31695832

ABSTRACT

We report a case of acute gouty monoarthritis of the left ankle in a 58-year-old female with chronic renal insufficiency after cryoablation of a 3.8 cm left renal cell carcinoma. The patient's symptoms resolved after intravenous Solumedrol and did not recur at her 1-month follow-up visit. To the best of our knowledge, this is the first reported case of acute gouty monoarthritis after cryoablation of a renal cell carcinoma lesion in a patient with underlying chronic renal insufficiency. Clinicians should be vigilant of the potential for this complication in at-risk patient populations.

9.
JACC Cardiovasc Interv ; 12(9): 859-869, 2019 05 13.
Article in English | MEDLINE | ID: mdl-31072507

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the safety and effectiveness of percutaneous mechanical thrombectomy using the FlowTriever System (Inari Medical, Irvine, California) in a prospective trial of patients with acute intermediate-risk pulmonary embolism (PE). BACKGROUND: Catheter-directed thrombolysis has been shown to improve right ventricular (RV) function in patients with PE. However, catheter-directed thrombolysis increases bleeding risk and many patients with PE have relative and absolute contraindications to thrombolysis. METHODS: Patients with symptomatic, computed tomography-documented PE and RV/left ventricular (LV) ratios ≥0.9 were eligible for enrollment. The primary effectiveness endpoint was core laboratory-assessed change in RV/LV ratio. The primary safety endpoint comprised device-related death, major bleeding, treatment-related clinical deterioration, pulmonary vascular injury, or cardiac injury within 48 h of thrombectomy. RESULTS: From April 2016 to October 2017, 106 patients were treated with the FlowTriever System at 18 U.S. sites. Two patients (1.9%) received adjunctive thrombolytics and were analyzed separately. Mean procedural time was 94 min; mean intensive care unit stay was 1.5 days. Forty-three patients (41.3%) did not require any intensive care unit stay. At 48 h post-procedure, average RV/LV ratio reduction was 0.38 (25.1%; p < 0.0001). Four patients (3.8%) experienced 6 major adverse events, with 1 patient (1.0%) experiencing major bleeding. One patient (1.0%) died, of undiagnosed breast cancer, through 30-day follow-up. CONCLUSIONS: Percutaneous mechanical thrombectomy with the FlowTriever System appears safe and effective in patients with acute intermediate-risk PE, with significant improvement in RV/LV ratio and minimal major bleeding. Potential advantages include immediate thrombus removal, absence of thrombolytic complications, and reduced need for post-procedural critical care.


Subject(s)
Cardiac Catheters , Pulmonary Embolism/therapy , Thrombectomy/instrumentation , Acute Disease , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , Pulmonary Embolism/diagnostic imaging , Pulmonary Embolism/physiopathology , Recovery of Function , Risk Assessment , Risk Factors , Suction/instrumentation , Thrombectomy/adverse effects , Time Factors , Treatment Outcome , United States , Ventricular Function, Left , Ventricular Function, Right
SELECTION OF CITATIONS
SEARCH DETAIL
...