Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Publication year range
1.
Nihon Shokakibyo Gakkai Zasshi ; 119(1): 66-71, 2022.
Article in Japanese | MEDLINE | ID: mdl-35022373

ABSTRACT

A 47-year-old man was referred to our hospital for detailed examination of a gastric polypoid lesion. Esophagogastroduodenoscopy revealed a raspberry-like polyp at the gastric body. Pathological examination of the biopsy specimen revealed this polypoid lesion to be a gastric adenocarcinoma. Endoscopic submucosal dissection was performed, and histopathological examination revealed that lesion to be a well-differentiated adenocarcinoma. Immunohistochemical staining showed that the neoplasm was positive for MUC5AC and negative for MUC6, CD10, and pepsinogen I, indicating that this lesion was a foveolar-type gastric adenocarcinoma. From about 10 years now, this patient has been undergoing esophagogastroduodenoscopy almost every year. This lesion was absent until six years ago. Five years ago, a small polypoid lesion appeared at the gastric body, and this lesion gradually enlarged. The present case showed the growing process of the foveolar-type gastric adenocarcinoma with a raspberry-like appearance.


Subject(s)
Adenocarcinoma , Endoscopic Mucosal Resection , Rubus , Stomach Neoplasms , Adenocarcinoma/diagnostic imaging , Adenocarcinoma/surgery , Gastric Mucosa , Humans , Male , Middle Aged , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/surgery
2.
Nihon Shokakibyo Gakkai Zasshi ; 115(7): 633-642, 2018.
Article in Japanese | MEDLINE | ID: mdl-29998986

ABSTRACT

Among 586 patients who underwent computed tomography colonography (CTC) from May 2012 to September 2017, 333 were diagnosed with colonic diverticulosis. The incidence of colonic diverticulosis increases with age. Despite a high frequency of ascending colonic diverticulosis, multiple diverticulosis (>10 in a colonic segment) were the most frequent in the sigmoid colon. In previous studies, the frequency of detection of colonic diverticulosis by CTC was higher than that by colonoscopy and barium enema. In addition, using CTC, the detection rate of colonic diverticulosis has been recently increasing, suggesting that CTC is the most sensitive procedure for detecting colonic diverticulosis.


Subject(s)
Colonic Polyps , Colonography, Computed Tomographic , Diverticulosis, Colonic/diagnostic imaging , Diverticulosis, Colonic/epidemiology , Colonoscopy , Humans , Sensitivity and Specificity , Tomography
3.
Nihon Shokakibyo Gakkai Zasshi ; 114(12): 2134-2141, 2017.
Article in Japanese | MEDLINE | ID: mdl-29213024

ABSTRACT

A 42-year-old man, who had stopped smoking almost one year ago, visited our hospital for hematochezia. He was diagnosed as having ulcerative colitis and was prescribed 5-amino salicylic acid and corticosteroids, which led to the remission of his disease. However, the disease relapsed after sufficient continuous corticosteroids administration and persisted despite 5-amino salicylic acid administration and intensive treatment with corticosteroids, immune modulators, leukocyte apheresis, and anti-TNF-α antibodies. Curiously, clinical remission was achieved after he resumed smoking, and colonoscopy revealed mucosal healing. Such remission may be attributable to anti-inflammatory effects of smoking nicotine and carbon oxides.


Subject(s)
Colitis, Ulcerative/etiology , Smoking , Adult , Colitis, Ulcerative/diagnosis , Colonoscopy , Humans , Male , Remission Induction , Smoking Cessation
4.
Talanta ; 81(4-5): 1467-71, 2010 Jun 15.
Article in English | MEDLINE | ID: mdl-20441924

ABSTRACT

Ammonium ion was colorized by means of a diazo coupling reaction with 2-phenylphenol, where the color development reaction was conducted within 3min by using boric acid as a catalyst. The resulting colored solution (0.5ml) was supplied by suction to a detecting tube consisting of a nonwoven fabric test strip (2mm wide, 1mm thick, 150mm long) impregnated with benzylcetyldimethylammonium chloride in a stripe pattern and enclosed in a heat-shrinkable tube. When the colored solution was supplied to the detecting tube, blue zebra-bands formed, and the ammonium concentration was determined by counting the number of zebra-bands. The detection range was 1-20mg-Nl(-1). Ammonium ion in actual domestic wastewater samples was successfully detected by means of this method.


Subject(s)
Chemistry Techniques, Analytical , Quaternary Ammonium Compounds/analysis , Water Pollutants, Chemical/isolation & purification , Water Purification/methods , Adsorption , Calibration , Filtration , Seasons , Solutions , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL