Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Neth Heart J ; 25(2): 65-75, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28083857

ABSTRACT

Advances in catheter-based interventions in structural and congenital heart disease have mandated an increased demand for three-dimensional (3D) visualisation of complex cardiac anatomy. Despite progress in 3D imaging modalities, the pre- and periprocedural visualisation of spatial anatomy is relegated to two-dimensional flat screen representations. 3D printing is an evolving technology based on the concept of additive manufacturing, where computerised digital surface renders are converted into physical models. Printed models replicate complex structures in tangible forms that cardiovascular physicians and surgeons can use for education, preprocedural planning and device testing. In this review we discuss the different steps of the 3D printing process, which include image acquisition, segmentation, printing methods and materials. We also examine the expanded applications of 3D printing in the catheter-based treatment of adult patients with structural and congenital heart disease while highlighting the current limitations of this technology in terms of segmentation, model accuracy and dynamic capabilities. Furthermore, we provide information on the resources needed to establish a hospital-based 3D printing laboratory.

2.
Heart ; 94(5): 571-2, 2008 May.
Article in English | MEDLINE | ID: mdl-17085529

ABSTRACT

BACKGROUND: Interventional procedures in adults with congenital cardiac conditions often require insertion of large-sized sheaths into the femoral veins. Data on the use of suture-mediated devices for femoral venous access site closure are scant and no data are available regarding venous patency after device use. OBJECTIVE: To assess the efficacy of the 6Fr Perclose (Abbott Vascular Devices, CA, USA) suture-mediated device in achieving haemostasis and venous patency after closure. DESIGN AND SETTING: 146 consecutive patients (80 women, mean (SD) age 45 (14) years) undergoing closure of 205 femoral venous access sites in a tertiary cardiac centre were studied. All received heparin and were taking concomitant aspirin or clopidogrel, or both. The majority (98%) had a >or=10Fr sheath inserted. RESULTS: Immediate haemostasis was achieved in 202 (99%) sites. Two patients (1.4%) had a major complication. On follow-up (111 patients, mean (SD) 71 (33) days) there was no evidence of haematoma or fistula formation. Doppler studies from a subgroup of 43 (29%) patients (mean (SD) age 45 (15) years, mean (SD) follow-up 47 (18) days) showed a common femoral venous diameter of 11.6 (2.7) mm on the device closed right and 12.2 (2.5) mm on the left vein (p>0.05). All accessed veins were patent with no pseudoaneurysm or arteriovenous fistula formation. CONCLUSION: Pre-closure of large-size sheath femoral venous access sites using the suture-mediated Perclose device is efficacious in achieving rapid haemostasis in the presence of anticoagulation. Doppler follow-up shows no loss of venous patency or luminal venous diameter as compared with the contralateral side.


Subject(s)
Catheterization/methods , Femoral Vein/surgery , Heart Defects, Congenital/surgery , Hemostasis, Surgical/instrumentation , Aged , Female , Heart Defects, Congenital/therapy , Hemostasis, Surgical/methods , Humans , Leg/blood supply , Male , Middle Aged , Postoperative Hemorrhage/prevention & control , Sutures/standards , Treatment Outcome , Ultrasonography, Doppler, Duplex
SELECTION OF CITATIONS
SEARCH DETAIL
...