Anal Chem ; 94(31): 10893-10906, 2022 08 09.
Article in English | MEDLINE | ID: mdl-35880733

ABSTRACT

With increasing sensitivity and accuracy in mass spectrometry, the tumor phosphoproteome is getting into reach. However, the selection of quantitation techniques best-suited to the biomedical question and diagnostic requirements remains a trial and error decision as no study has directly compared their performance for tumor tissue phosphoproteomics. We compared label-free quantification (LFQ), spike-in-SILAC (stable isotope labeling by amino acids in cell culture), and tandem mass tag (TMT) isobaric tandem mass tags technology for quantitative phosphosite profiling in tumor tissue. Compared to the classic SILAC method, spike-in-SILAC is not limited to cell culture analysis, making it suitable for quantitative analysis of tumor tissue samples. TMT offered the lowest accuracy and the highest precision and robustness toward different phosphosite abundances and matrices. Spike-in-SILAC offered the best compromise between these features but suffered from a low phosphosite coverage. LFQ offered the lowest precision but the highest number of identifications. Both spike-in-SILAC and LFQ presented susceptibility to matrix effects. Match between run (MBR)-based analysis enhanced the phosphosite coverage across technical replicates in LFQ and spike-in-SILAC but further reduced the precision and robustness of quantification. The choice of quantitative methodology is critical for both study design such as sample size in sample groups and quantified phosphosites and comparison of published cancer phosphoproteomes. Using ovarian cancer tissue as an example, our study builds a resource for the design and analysis of quantitative phosphoproteomic studies in cancer research and diagnostics.


Subject(s)
Ovarian Neoplasms , Proteomics , Female , Humans , Isotope Labeling/methods , Mass Spectrometry/methods , Ovarian Neoplasms/diagnosis , Proteome/chemistry , Proteomics/methods
2.
Steroids ; 152: 108477, 2019 12.
Article in English | MEDLINE | ID: mdl-31446013

ABSTRACT

The population based Steroid Profile (SP) ratio of testosterone (T) and epitestosterone (E) has been considered as a biomarker approach to detect testosterone abuse in '80s. The contemporary Antidoping Laboratories apply the World Antidoping Agency (WADA) Technical Document (TD) for Endogenous Androgenic Anabolic Steroids (EAAS) in the analysis of SP during their screening. The SP Athlete Biological Passport (ABP) adaptive model uses the concentrations of the total of free and glucuronide conjugated forms of six EAASs concentrations and ratios measured by GC/MS. In the Antidoping Lab Qatar (ADLQ), the routine LC/MS screening method was used to quantitatively estimate the sulfate conjugated EAAS in the same analytical run as for the rest qualitative analytes. Seven sulfate EAAS were quantified for a number of routine antidoping male and female urine samples during screening. Concentrations, statistical parameters and selected ratios for the 6 EAAS, the 6 sulfate EAAS and 29 proposed ratios of concentrations from both EAAS and sulfate EAAS, which potentially used as SP ABP biomarkers, population reference limits and distributions have been estimated after the GC/MSMS analysis for EAAS and LC/Orbitrap/MS analysis for sulfate EAAS.


Subject(s)
Sports , Steroids/urine , Substance Abuse Detection , Sulfates/urine , Athletes , Female , Gas Chromatography-Mass Spectrometry , Humans , Male , Reference Values
3.
PLoS One ; 13(12): e0208389, 2018.
Article in English | MEDLINE | ID: mdl-30521568

ABSTRACT

Prescription sequence symmetry analysis (PSSA), a case-only design introduced in 1996, has been increasingly used to identify unintentional drug effects, and has potential applications as a hypothesis-testing and a hypothesis-generating method, due to its easy application and effective control of time-invariant confounders. The aim of this study is to systematically compare effect estimates from the PSSA to effect estimates from conventional observational parallel group study designs, to assess the validity and constraints of the PSSA study design. We reviewed the MEDLINE, EMBASE, and Web of Science databases until February 2016 to identify studies that compared PSSA to a parallel group design. Data from the eligible articles was extracted and analyzed, including making a Bland-Altman plot and calculating the number of discrepancies between the designs. 63 comparisons (from two studies) were included in the review. There was a significant correlation (p < 0.001) between the effect estimates of the PSSA and the parallel group designs, but the bias indicated by the Bland-Altman plot (0.20) and the percentage of discrepancies (70-80%) showed that this correlation was not accompanied by a considerable similarity of the effect estimates. Overall, the effect estimates of the parallel group designs were higher than those of the PSSA, not necessarily further away from 1, and the parallel group designs also generated more significant signals. However, these results should be approached with caution, as the effect estimates were only retrieved from two separate studies. This review indicates that, even though PSSA has a lot of potential, the effect estimates generated by the PSSA are usually lower than the effect estimates generated by parallel group designs, and PSSA mostly has a lower power than the conventional study designs, but this is based on limited comparisons, and more comparisons are needed to make a proper conclusion.


Subject(s)
Databases, Factual , Prescriptions , Humans , Models, Theoretical
4.
Oncotarget ; 9(26): 18128-18147, 2018 Apr 06.
Article in English | MEDLINE | ID: mdl-29719595

ABSTRACT

Laser capture microdissection (LCM) allows the capture of cell types or well-defined structures in tissue. We compared in a semi-quantitative way the proteomes from an equivalent of 8,000 tumor cells from patients with squamous cell cervical cancer (SCC, n = 22) with healthy epithelial and stromal cells obtained from normal cervical tissue (n = 13). Proteins were enzymatically digested into peptides which were measured by high-resolution mass spectrometry and analyzed by "all-or-nothing" analysis, Bonferroni, and Benjamini-Hochberg correction for multiple testing. By comparing LCM cell type preparations, 31 proteins were exclusively found in early stage cervical cancer (n = 11) when compared with healthy epithelium and stroma, based on criteria that address specificity in a restrictive "all-or-nothing" way. By Bonferroni correction for multiple testing, 30 proteins were significantly up-regulated between early stage cervical cancer and healthy control, including six members of the MCM protein family. MCM proteins are involved in DNA repair and expected to be participating in the early stage of cancer. After a less stringent Benjamini-Hochberg correction for multiple testing, we found that the abundances of 319 proteins were significantly different between early stage cervical cancer and healthy controls. Four proteins were confirmed in digests of whole tissue lysates by Parallel Reaction Monitoring (PRM). Ingenuity Pathway Analysis using correction for multiple testing by permutation resulted in two networks that were differentially regulated in early stage cervical cancer compared with healthy tissue. From these networks, we learned that specific tumor mechanisms become effective during the early stage of cervical cancer.

5.
J Pharm Biomed Anal ; 151: 10-24, 2018 Mar 20.
Article in English | MEDLINE | ID: mdl-29291455

ABSTRACT

The aim of this paper is to present the development and validation of a high-resolution full scan (HR-FS) electrospray ionization (ESI) liquid chromatography coupled to quadrupole Orbitrap mass spectrometer (LC/Q/Orbitrap MS) platform for the screening of prohibited substances in human urine according to World Antidoping Agency (WADA) requirements. The method was also validated for quantitative analysis of six endogenous steroids (epitestosterone, testosterone, 5α-dihydrotestosterone, dehydroepiandrosterone, androsterone and etiocholanolone) in their intact sulfates form. The sample preparation comprised a combination of a hydrolyzed urine liquid-liquid extraction and the dilute & shoot addition of original urine in the extracted aliquot. The HR-FS MS acquisition mode with Polarity Switching was applied in combination of the Quadrupole-Orbitrap mass filter. The HR-FS acquisition of analytical signal, for known and unknown small molecules, allows the inclusion of all analytes detectable with LC-MS for antidoping investigations to identify the use of known or novel prohibited substances and metabolites after electronic data files' reprocessing. The method has been validated to be fit-for-purpose for the antidoping analysis.


Subject(s)
Doping in Sports/prevention & control , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Urinalysis/methods , Anabolic Agents/urine , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Diuretics/urine , Humans , Spectrometry, Mass, Electrospray Ionization/standards , Tandem Mass Spectrometry/standards , Urinalysis/standards
6.
Article in English | MEDLINE | ID: mdl-28850889

ABSTRACT

This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World Antidoping Agency (WADA) enlists AAS as prohibited doping agents in sports, and our method has been developed to comply with the qualitative specifications of WADA to be applied for the detection of sports antidoping prohibited substances, mainly for AAS. The method also comprises of the quantitative analysis of the WADA's Athlete Biological Passport (ABP) endogenous steroidal parameters. The applied preparation of urine samples includes enzymatic hydrolysis for the cleavage of the Phase II glucuronide conjugates, generic liquid-liquid extraction and trimethylsilyl (TMS) derivatization steps. Tandem mass spectrometry (MS/MS) acquisition was applied on few selected ions to enhance the specificity and sensitivity of GC/TOF signal of few compounds. The full scan high resolution acquisition of analytical signal, for known and unknown TMS derivatives of AAS provides the antidoping system with a new analytical tool for the detection designer drugs and novel metabolites, which prolongs the AAS detection, after electronic data files' reprocessing. The current method is complementary to the respective liquid chromatography coupled to mass spectrometry (LC/MS) methodology widely used to detect prohibited molecules in sport, which cannot be efficiently ionized with atmospheric pressure ionization interface.


Subject(s)
Anabolic Agents/urine , Doping in Sports/prevention & control , Gas Chromatography-Mass Spectrometry/methods , Androsterone/urine , Child , Epitestosterone/urine , Female , Humans , Limit of Detection , Linear Models , Reproducibility of Results
8.
PLoS One ; 9(7): e102037, 2014.
Article in English | MEDLINE | ID: mdl-25036363

ABSTRACT

Cigarette smoking is the main risk factor for COPD (Chronic Obstructive Pulmonary Disease), yet only a subset of smokers develops COPD. Family members of patients with severe early-onset COPD have an increased risk to develop COPD and are therefore defined as "susceptible individuals". Here we perform unbiased analyses of proteomic profiles to assess how "susceptible individuals" differ from age-matched "non-susceptible individuals" in response to cigarette smoking. Epithelial lining fluid (ELF) was collected at baseline and 24 hours after smoking 3 cigarettes in young individuals susceptible or non-susceptible to develop COPD and older subjects with established COPD. Controls at baseline were older healthy smoking and non-smoking individuals. Five samples per group were pooled and analysed by stable isotope labelling (iTRAQ) in duplicate. Six proteins were selected and validated by ELISA or immunohistochemistry. After smoking, 23 proteins increased or decreased in young susceptible individuals, 7 in young non-susceptible individuals, and 13 in COPD in the first experiment; 23 proteins increased or decreased in young susceptible individuals, 32 in young non-susceptible individuals, and 11 in COPD in the second experiment. SerpinB3 and Uteroglobin decreased after acute smoke exposure in young non-susceptible individuals exclusively, whereas Peroxiredoxin I, S100A9, S100A8, ALDH3A1 (Aldehyde dehydrogenase 3A1) decreased both in young susceptible and non-susceptible individuals, changes being significantly different between groups for Uteroglobin with iTRAQ and for Serpin B3 with iTRAQ and ELISA measures. Peroxiredoxin I, SerpinB3 and ALDH3A1 increased in COPD patients after smoking. We conclude that smoking induces a differential protein response in ELF of susceptible and non-susceptible young individuals, which differs from patients with established COPD. This is the first study applying unbiased proteomic profiling to unravel the underlying mechanisms that induce COPD. Our data suggest that SerpinB3 and Uteroglobin could be interesting proteins in understanding the processes leading to COPD.


Subject(s)
Proteomics , Pulmonary Disease, Chronic Obstructive/etiology , Pulmonary Disease, Chronic Obstructive/metabolism , Smoking/adverse effects , Adolescent , Adult , Disease Susceptibility , Epithelium/metabolism , Female , Humans , Male , Middle Aged , Time Factors , Young Adult
9.
Clin Chem ; 57(12): 1703-11, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21998343

ABSTRACT

BACKGROUND: Because cerebrospinal fluid (CSF) is in close contact with diseased areas in neurological disorders, it is an important source of material in the search for molecular biomarkers. However, sample handling for CSF collected from patients in a clinical setting might not always be adequate for use in proteomics and metabolomics studies. METHODS: We left CSF for 0, 30, and 120 min at room temperature immediately after sample collection and centrifugation/removal of cells. At 2 laboratories CSF proteomes were subjected to tryptic digestion and analyzed by use of nano-liquid chromatography (LC) Orbitrap mass spectrometry (MS) and chipLC quadrupole TOF-MS. Metabolome analysis was performed at 3 laboratories by NMR, GC-MS, and LC-MS. Targeted analyses of cystatin C and albumin were performed by LC-tandem MS in the selected reaction monitoring mode. RESULTS: We did not find significant changes in the measured proteome and metabolome of CSF stored at room temperature after centrifugation, except for 2 peptides and 1 metabolite, 2,3,4-trihydroxybutanoic (threonic) acid, of 5780 identified peptides and 93 identified metabolites. A sensitive protein stability marker, cystatin C, was not affected. CONCLUSIONS: The measured proteome and metabolome of centrifuged human CSF is stable at room temperature for up to 2 hours. We cannot exclude, however, that changes undetectable with our current methodology, such as denaturation or proteolysis, might occur because of sample handling conditions. The stability we observed gives laboratory personnel at the collection site sufficient time to aliquot samples before freezing and storage at -80 °C.


Subject(s)
Metabolome , Proteome/metabolism , Specimen Handling , Cerebrospinal Fluid , Chromatography, Gas , Chromatography, Liquid , Humans , Magnetic Resonance Spectroscopy , Mass Spectrometry/methods , Time Factors
10.
Eur J Mass Spectrom (Chichester) ; 16(1): 101-21, 2010.
Article in English | MEDLINE | ID: mdl-20065518

ABSTRACT

In this review we will give an overview of the issues related to biomarker discovery studies with a focus on liquid chromatography-mass spectrometry (LC-MS) methods. Biomarker discovery is based on a close collaboration between clinicians, analytical scientists and chemometritians/statisticians. It is critical to define the final purpose of a biomarker or biomarker pattern at the onset of the study and to select case and control samples accordingly. This is followed by designing the experiment, starting with the sampling strategy, sample collection, storage and separation protocols, choice and validation of the quantitative profiling platform followed by data processing, statistical analysis and validation workflows. Biomarker candidates that result after statistical validation should be submitted for further validation and, ideally, be connected to the disease mechanism after their identification. Since most discovery studies work with a relatively small number of samples, it is necessary to assess the specificity and sensitivity of a given biomarker-based assay in a larger set of independent samples, preferably analyzed at another clinical center. Targeted analytical methods of higher throughput than the original discovery method are needed at this point and LC-tandem mass spectrometry is gaining acceptance in this field. Throughout this review, we will focus on possible sources of variance and how they can be assessed and reduced in order to avoid false positives and to reduce the number of false negatives in biomarker discovery research.


Subject(s)
Biomarkers/analysis , Chromatography, Liquid/methods , Mass Spectrometry/methods
11.
J Proteome Res ; 9(3): 1483-95, 2010 Mar 05.
Article in English | MEDLINE | ID: mdl-20070124

ABSTRACT

Time alignment of complex LC-MS data remains a challenge in proteomics and metabolomics studies. This work describes modifications of the Dynamic Time Warping (DTW) and the Parametric Time Warping (PTW) algorithms that improve the alignment quality for complex, highly variable LC-MS data sets. Regular DTW or PTW use one-dimensional profiles such as the Total Ion Chromatogram (TIC) or Base Peak Chromatogram (BPC) resulting in correct alignment if the signals have a relatively simple structure. However, when aligning the TICs of chromatograms from complex mixtures with large concentration variability such as serum or urine, both algorithms often lead to misalignment of peaks and thus incorrect comparisons in the subsequent statistical analysis. This is mainly due to the fact that compounds with different m/z values but similar retention times are not considered separately but confounded in the benefit function of the algorithms using only one-dimensional information. Thus, it is necessary to treat the information of different mass traces separately in the warping function to ensure that compounds having the same m/z value and retention time are aligned to each other. The Component Detection Algorithm (CODA) is widely used to calculate the quality of an LC-MS mass trace. By combining CODA with the warping algorithms of DTW or PTW (DTW-CODA or PTW-CODA), we include only high quality mass traces measured by CODA in the benefit function. Our results show that using several CODA selected high quality mass traces in DTW-CODA and PTW-CODA significantly improves the alignment quality of three different, highly complex LC-MS data sets. Moreover, DTW-CODA leads to better preservation of peak shape as compared to the original DTW-TIC algorithm, which often suffers from a substantial peak shape distortion. Our results show that combination of CODA selected mass traces with different time alignment algorithm is a general principle that provide accurate alignment for highly complex samples with large concentration variability.


Subject(s)
Algorithms , Chromatography, Liquid/methods , Computational Biology/methods , Mass Spectrometry/methods , Metabolomics/methods , Blood Proteins/analysis , Databases, Factual , Humans , Proteinuria/blood , Time Factors , Trypsin/chemistry , Trypsin/metabolism , Urine/chemistry
12.
J Proteome Res ; 8(12): 5511-22, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19845411

ABSTRACT

To standardize the use of cerebrospinal fluid (CSF) for biomarker research, a set of stability studies have been performed on porcine samples to investigate the influence of common sample handling procedures on proteins, peptides, metabolites and free amino acids. This study focuses at the effect on proteins and peptides, analyzed by applying label-free quantitation using microfluidics nanoscale liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (chipLC-MS) as well as matrix-assisted laser desorption ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FT-ICR-MS) and Orbitrap LC-MS/MS to trypsin-digested CSF samples. The factors assessed were a 30 or 120 min time delay at room temperature before storage at -80 degrees C after the collection of CSF in order to mimic potential delays in the clinic (delayed storage), storage at 4 degrees C after trypsin digestion to mimic the time that samples remain in the cooled autosampler of the analyzer, and repeated freeze-thaw cycles to mimic storage and handling procedures in the laboratory. The delayed storage factor was also analyzed by gas chromatography mass spectrometry (GC-MS) and liquid chromatography mass spectrometry (LC-MS) for changes of metabolites and free amino acids, respectively. Our results show that repeated freeze/thawing introduced changes in transthyretin peptide levels. The trypsin digested samples left at 4 degrees C in the autosampler showed a time-dependent decrease of peak areas for peptides from prostaglandin D-synthase and serotransferrin. Delayed storage of CSF led to changes in prostaglandin D-synthase derived peptides as well as to increased levels of certain amino acids and metabolites. The changes of metabolites, amino acids and proteins in the delayed storage study appear to be related to remaining white blood cells. Our recommendations are to centrifuge CSF samples immediately after collection to remove white blood cells, aliquot, and then snap-freeze the supernatant in liquid nitrogen for storage at -80 degrees C. Preferably samples should not be left in the autosampler for more than 24 h and freeze/thaw cycles should be avoided if at all possible.


Subject(s)
Cerebrospinal Fluid/chemistry , Protein Stability , Proteome/chemistry , Specimen Handling/methods , Tissue Preservation/methods , Amino Acids , Biomarkers/cerebrospinal fluid , Cryopreservation , Humans , Intramolecular Oxidoreductases/metabolism , Leukocytes/chemistry , Leukocytes/metabolism , Lipocalins/metabolism , Metabolomics , Peptides , Proteins , Proteome/metabolism , Proteomics/methods , Reference Standards , Specimen Handling/standards , Tissue Preservation/standards
13.
Anal Chem ; 80(18): 7012-21, 2008 Sep 15.
Article in English | MEDLINE | ID: mdl-18715018

ABSTRACT

Correlation optimized warping (COW) based on the total ion current (TIC) is a widely used time alignment algorithm (COW-TIC). This approach works successfully on chromatograms containing few compounds and having a well-defined TIC. In this paper, we have combined COW with a component detection algorithm (CODA) to align LC-MS chromatograms containing thousands of biological compounds with overlapping chromatographic peaks, a situation where COW-TIC often fails. CODA is a variable selection procedure that selects mass chromatograms with low noise and low background (so-called "high-quality" mass chromatograms). High-quality mass chromatograms selected in each COW segment ensure that the same compounds (based on their mass and their retention time) are used in the two-dimensional benefit function of COW to obtain correct and optimal alignments (COW-CODA). The performance of the COW-CODA algorithm was evaluated on three types of complex data sets obtained from the LC-MS analysis of samples commonly used for biomarker discovery and compared to COW-TIC using a new global comparison method based on overlapping peak area: trypsin-digested serum obtained from cervical cancer patients, trypsin-digested serum from a single patient that was treated with varying preanalytical parameters (factorial design study), and urine from pregnant and nonpregnant women. While COW-CODA did result in minor misalignments in rare cases, it was clearly superior to the COW-TIC algorithm, especially when applied to highly variable chromatograms (factorial design, urine). The presented algorithm thus enables automatic time alignment and accurate peak matching of multiple LC-MS data sets obtained from complex body fluids that are often used for biomarker discovery.


Subject(s)
Algorithms , Chromatography, Liquid/methods , Mass Spectrometry/methods , Female , Humans , Pregnancy , Reference Standards , Reproducibility of Results , Time Factors , Trypsin/metabolism , Urine/chemistry , Uterine Cervical Neoplasms/blood
14.
J Proteome Res ; 6(1): 194-206, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17203964

ABSTRACT

We describe a platform for the comparative profiling of urine using reversed-phase liquid chromatography-mass spectrometry (LC-MS) and multivariate statistical data analysis. Urinary compounds were separated by gradient elution and subsequently detected by electrospray Ion-Trap MS. The lower limit of detection (5.7-21 nmol/L), within-day (2.9-19%) and between-day (4.8-19%) analytical variation of peak areas, linearity (R2: 0.918-0.999), and standard deviation for retention time (<0.52 min) of the method were assessed by means of addition of seven 3-8 amino acid peptides (0-500 nmol/L). Relating the amount of injected urine to the area under the curve (AUC) of the chromatographic trace at 214 nm better reduced the coefficient of variation (CV) of the AUC of the total ion chromatogram (CV = 10.1%) than relating it to creatinine (CV = 38.4%). LC-MS data were processed, and the common peak matrix was analyzed by principal component analysis (PCA) after supervised classification by the nearest shrunken centroid algorithm. The feasibility of the method to discriminate urine samples of differing compositions was evaluated by (i) addition of seven peptides at nanomolar concentrations to blank urine samples of different origin and (ii) a study of urine from kidney patients with and without proteinuria. (i) The added peptides were ranked as highly discriminatory peaks despite significant biological variation. (ii) Ninety-two peaks were selected best discriminating proteinuric from nonproteinuric samples, of which 6 were more intense in the majority of the proteinuric samples. Two of these 6 peaks were identified as albumin-derived peptides, which is in accordance with the early rise of albumin during glomerular proteinuria. Interestingly, other albumin-derived peptides were nondiscriminatory indicating preferential proteolysis at some cleavage sites.


Subject(s)
Chromatography, Liquid/methods , Mass Spectrometry/methods , Proteinuria/diagnosis , Proteinuria/urine , Urinalysis/methods , Algorithms , Amino Acid Sequence , Area Under Curve , Biomarkers/metabolism , Databases, Factual , Humans , Kidney Diseases/urine , Molecular Sequence Data , Multivariate Analysis , Principal Component Analysis , Signal Processing, Computer-Assisted