Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
AJR Am J Roentgenol ; 186(6): 1502-11, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16714637

ABSTRACT

OBJECTIVE: This study compared MR during arterial portography (MRAP) with CT during arterial portography (CTAP) with regard to the detection and differentiation of liver metastases before surgery. MATERIALS AND METHODS: Fifteen patients with liver metastases were enrolled before surgery according to the guidelines of our institutional review board and good clinical practice. After mesentericography, unenhanced scans (Volume Zoom) were performed initially. For CTAP, the contrast medium was injected through the superior mesenteric artery. Images were acquired in portal and delayed enhancement. The MR protocol (1.5 T; Magnetom Symphony) started with T1-weighted fast low-angle shot (FLASH) T2-weighted turbo spin echo (TSE). MRAP followed with gadolinium-enhanced dynamic T1-weighted 3D FLASH. Delayed-phase T1-weighted 2D FLASH axial images were performed 2 min after IV injection of the contrast medium. Qualitative and quantitative evaluation of CTAP and MRAP was performed by three blinded radiologists regarding the number of lesions and their size, localization, and differential diagnosis. RESULTS: The overall sensitivity in detecting liver metastases was 97% with MRAP and 93% with CTAP (p > 0.05, not significant [n.s.]). The specificity was calculated to be 97% for MRAP and 82% for CTAP (p < 0.0001, statistically significant [s.s.]). The differences in sensitivity were more accentuated if only lesions 10 mm or smaller were considered (95% vs 88%, p > 0.05, n.s.), for which the respective specificities were 95% and 80% (p < 0.0014, s.s.). Improvements in sensitivity and specificity were associated with a higher lesion-to-liver contrast-to-noise ratio (59.4 +/- 51.0 for MRAP vs 10.4 +/- 7.3 for CTAP) and resulted in higher diagnostic confidence in the differential diagnosis of liver lesions (p < 0.001, s.s.) and better interobserver agreement (median kappa value, 0.88 vs 0.63). CONCLUSION: MRAP proved to be a reliable method in the preoperative detection of small liver metastases in particular, with a higher sensitivity and specificity than CTAP. If organizational difficulties of MRAP can be overcome, MRAP could be considered instead of CTAP in the preoperative invasive evaluation of metastatic liver disease.


Subject(s)
Liver Neoplasms/diagnosis , Liver Neoplasms/secondary , Magnetic Resonance Imaging , Portography , Tomography, X-Ray Computed , Adult , Aged , Female , Humans , Male , Middle Aged , Sensitivity and Specificity
2.
Eur Radiol ; 13(4): 794-801, 2003 Apr.
Article in English | MEDLINE | ID: mdl-12664119

ABSTRACT

The aim of this study was to assess the value of contrast-enhanced three-dimensional MR angiography (CE 3D MRA) in the preoperative assessment of potential living renal donors, and to compare the accuracy for the depiction of the vascular anatomy using three different rendering algorithms. Twenty-three potential living renal donors were examined with CE 3D MRA (TE/TR=1.3 ms/3.7 ms, field of view 260-320x350 mm, 384-448x512 matrix, slab thickness 9.4 cm, 72 partitions, section thickness 1.3 mm, scan time 24 s, 0.1 mmol/kg body weight gadobenate dimeglumine). Magnetic resonance angiography data sets were processed with maximum intensity projection (MIP), volume rendering (VR), and shaded-surface display (SSD) algorithms. The image analysis was performed independently by three MR-experienced radiologists recording the number of renal arteries, the presence of early branching or vascular pathology. The combination of digital subtraction angiography (DSA) and intraoperative findings served as the gold standard for the image analysis. In total, 52 renal arteries were correspondingly observed in 23 patients at DSA and surgery. Other findings were 3 cases of early branching of the renal arteries, 4 cases of arterial stenosis and 1 case of bilateral fibromuscular dysplasia. With MRA source data all 52 renal arteries were correctly identified by all readers, compared with 51 (98.1%), 51-52 (98.1-100%) and 49-50 renal arteries (94.2-96.2%) with the MIP, VR and SSD projections, respectively. Similarly, the sensitivity, specificity and accuracy was highest with the MRA source data followed by MIP, VR and SSD. Time requirements were lowest for the MIP reconstructions and highest for the VR reconstructions. Contrast-enhanced 3D MRA is a reliable, non-invasive tool for the preoperative evaluation of potential living renal donors. Maximum intensity projection is favourable for the processing of 3D MRA data, as it has minimal time and computational requirements, while having similar or superior accuracy for the depiction of vessel anomalies or pathology compared with VR and SSD, respectively.


Subject(s)
Algorithms , Kidney Transplantation , Living Donors , Magnetic Resonance Angiography , Meglumine/analogs & derivatives , Angiography, Digital Subtraction , Contrast Media , Female , Gadolinium , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Male , Middle Aged , Organometallic Compounds , Renal Artery/anatomy & histology , Sensitivity and Specificity
3.
Clin Radiol ; 57(10): 902-7, 2002 Oct.
Article in English | MEDLINE | ID: mdl-12413914

ABSTRACT

AIM: The aim of this study was to evaluate the image quality and the potential for radiation dose reduction with a digital flat-panel amorphous silicon detector radiography system. MATERIAL AND METHODS: Using flat-panel technology, radiographs of an anthropomorphic thorax phantom were taken with a range of technical parameters (125kV, 200mA and 5, 4, 3.2, 2, 1, 0.5, and 0.25mAs) which were equivalent to a radiation dose of 332, 263, 209, 127, 58.7, 29, and 14 microGy, respectively. These images were compared to radiographs obtained by a conventional film-screen radiography system at 125kV, 200mA and 5mAs (equivalent to 252 microGy) which served as reference. Three observers evaluated independently the visibility of simulated rounded lesions and anatomical structures, comparing printed films from the flat-panel amorphous silicon detector and conventional x-ray system films. RESULTS: With flat-panel technology, the visibility of rounded lesions and normal anatomical structures at 5, 4, and 3.2mAs was superior compared to the conventional film-screen radiography system. (P< or =0.0001). At 2mAs, improvement was only marginal (P=0.19). At 1.0, 0.5 and 0.25mAs, the visibility of simulated rounded lesions was worse (P< or =0.004). Comparing fine lung parenchymal structures, the flat-panel amorphous silicon detector showed improvement for all exposure levels down to 2mAs and equality at 1mAs. CONCLUSION: Compared to a conventional x-ray film system, the flat-panel amorphous silicon detector demonstrated improved image quality and the possibility for a reduction of the radiation dose by 50% without loss in image quality.


Subject(s)
Radiographic Image Enhancement/instrumentation , Radiography, Thoracic/instrumentation , Silicon , Humans , Phantoms, Imaging , Radiation Dosage , Radiography, Thoracic/standards
4.
Z Gastroenterol ; 37(7): 615-22, 1999 Jul.
Article in English | MEDLINE | ID: mdl-10458011

ABSTRACT

Pseudomyxoma peritonei (PMP) is rare clinical entity presenting with mucus-producing lesions on the peritoneal surface. PMP is found in middle-aged or older patients in approximately two out of 10,000 laparotomies. Most of the reported cases are due to a primary process located in either appendix or the ovaries. PMP presents with an insidious onset of symptoms, and is characterized by long-term survival with good general health and absence of visceral invasion or distant metastasis. The treatment of choice for PMP is surgical resection and the removal of free mucus. Despite a high rate of disease recurrence, adjuvant or palliative chemotherapy has not yet been clearly established. In our opinion, intraperitoneal application may be more effective than a systemic regimen because only local treatment can provide sufficient concentrations of chemotherapeutic agents. In view of the lack of standardized treatment regimens and based on our experience, we recommend intraperitoneal chemotherapy with 5-FU and mitomycin C or cisplatin. We report ten cases of PMP of appendiceal origin and present a review of the literature on this disease and its treatment.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Appendiceal Neoplasms/surgery , Peritoneal Neoplasms/surgery , Pseudomyxoma Peritonei/surgery , Adult , Aged , Antineoplastic Combined Chemotherapy Protocols/adverse effects , Appendiceal Neoplasms/drug therapy , Appendiceal Neoplasms/mortality , Appendiceal Neoplasms/pathology , Chemotherapy, Adjuvant , Chemotherapy, Cancer, Regional Perfusion , Cisplatin/administration & dosage , Combined Modality Therapy , Female , Fluorouracil/administration & dosage , Follow-Up Studies , Humans , Male , Middle Aged , Mitomycin/administration & dosage , Peritoneal Neoplasms/drug therapy , Peritoneal Neoplasms/mortality , Peritoneal Neoplasms/pathology , Pseudomyxoma Peritonei/drug therapy , Pseudomyxoma Peritonei/mortality , Pseudomyxoma Peritonei/pathology , Survival Rate
SELECTION OF CITATIONS
SEARCH DETAIL
...