Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Rev Sci Instrum ; 85(11): 11D815, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430228

ABSTRACT

The pre-existing ORNL scrape-off-layer (SOL) reflectometer that operated with the X-mode R-cutoff at 6-27 GHz to measure SOL density profiles on NSTX is being upgraded to be functional at the increased magnetic fields on NSTX-U spherical tokamak. Rather than increasing the operating frequencies to measure the higher X-mode R-cutoff frequencies on NSTX-U, it will be shown that the combined use of the X-mode R, L and O-mode cutoffs at 6-27 GHz can obtain the desired SOL density profiles. The potential capabilities and obstacles of this technique to measure SOL density profiles and possibly SOL magnetic field profiles on NSTX-U will be discussed.

2.
Phys Rev Lett ; 109(4): 045001, 2012 Jul 27.
Article in English | MEDLINE | ID: mdl-23006093

ABSTRACT

A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive.

3.
Phys Rev Lett ; 106(5): 055003, 2011 Feb 04.
Article in English | MEDLINE | ID: mdl-21405404

ABSTRACT

Negative magnetic shear is found to suppress electron turbulence and improve electron thermal transport for plasmas in the National Spherical Torus Experiment (NSTX). Sufficiently negative magnetic shear results in a transition out of a stiff profile regime. Density fluctuation measurements from high-k microwave scattering are verified to be the electron temperature gradient (ETG) mode by matching measured rest frequency and linear growth rate to gyrokinetic calculations. Fluctuation suppression under negligible E×B shear conditions confirm that negative magnetic shear alone is sufficient for ETG suppression. Measured electron temperature gradients can significantly exceed ETG critical gradients with ETG mode activity reduced to intermittent bursts, while electron thermal diffusivity improves to below 0.1 electron gyro-Bohms.

4.
Phys Rev Lett ; 101(7): 075001, 2008 Aug 15.
Article in English | MEDLINE | ID: mdl-18764544

ABSTRACT

Measurements with coherent scattering of electromagnetic waves in plasmas of the National Spherical Torus Experiment indicate the existence of turbulent fluctuations in the range of wave numbers k perpendicular rho(e)=0.1-0.4, corresponding to a turbulence scale length nearly equal to the collisionless skin depth. Experimental observations and agreement with numerical results from a linear gyrokinetic stability code support the conjecture that the observed turbulence is driven by the electron-temperature gradient.

5.
Phys Rev Lett ; 90(16): 165001, 2003 Apr 25.
Article in English | MEDLINE | ID: mdl-12731979

ABSTRACT

In the CDX-U spherical torus, agreement between radiation temperature and Thomson scattering electron temperature profiles indicates approximately 100% conversion of thermally emitted electron Bernstein waves to the X mode. This has been achieved by controlling the electron density scale length (L(n)) in the conversion region with a local limiter outside the last closed flux surface, shortening L(n) to the theoretically required value for optimal conversion. From symmetry of the conversion process, prospects for efficient coupling in heating and current drive scenarios are strongly supported.

11.
Rev Sci Instrum ; 50(8): 949-51, 1979 Aug.
Article in English | MEDLINE | ID: mdl-18699641

ABSTRACT

We have developed a fast-scanning heterodyne receiver into a plasma diagnostic that measures the fundamental cyclotron emission from the PLT plasma and thus ascertains the time evolution of the electron temperature profile. The receiver scans 60-90 GHz every 10 ms and is interfaced to a computer for completely automated calibrated temperature measurements.

12.
J Natl Cancer Inst ; 58(4): 905-11, 1977 Apr.
Article in English | MEDLINE | ID: mdl-300437

ABSTRACT

Multiple immunologic parameters were studied in three patients prior to and after hyperthermia treatment for disseminated malignancy. Two patients had malignant melanoma and received chemotherapy during the hyperthermia treatment. One had adenocarcinoma of the stomach and received no concomitant chemotherapy. Rapid rosettes as a measure of thymus-derived lymphocytes (T-lymphocytes) were found to increase significantly after therapy (P less than 0.05) both in percentage and absolute numbers. There was no change in the numbers or percentages of other markers for T-lymphocytes or bone marrow-derived B-lymphocytes. Complement profiles revealed a significant decrease in C3 (P less than 0.005) after hyperthermia but no change in levels of other components of the alternate pathway. Antibody-dependent lymphocyte-mediated cytotoxicity and polymorphonuclear cell-mediated antibody-dependent cytotoxicity were also depressed after hyperthermia. No change was observed in immunoglobulin levels with hyperthermia therapy. Results indicated that hyperthermia may favorably alter the immune balance between tumor and host in selected instances.


Subject(s)
Adenocarcinoma/therapy , Antineoplastic Agents/therapeutic use , Hyperthermia, Induced , Immunity , Melanoma/therapy , Skin Neoplasms/therapy , Stomach Neoplasms/therapy , Adenocarcinoma/immunology , Adult , B-Lymphocytes/immunology , Complement System Proteins/analysis , Humans , Immunoglobulins/analysis , Leukocyte Count , Lymphocyte Activation , Male , Melanoma/immunology , Middle Aged , Neoplasm Metastasis , Skin Neoplasms/immunology , Stomach Neoplasms/immunology , T-Lymphocytes/immunology
SELECTION OF CITATIONS
SEARCH DETAIL
...