Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Vasc Endovascular Surg ; 58(3): 343-349, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37944002

ABSTRACT

BACKGROUND: When treating aortic aneurysm patients with complex anatomical features, preprocedural planning aided by 3D-printed models offers valuable insights for endovascular intervention. This study highlights the use of stereolithographic (SLA) 3D printing to fabricate a phantom of a challenging aortic arch aneurysm with a complex neck anatomy. CLINICAL CASE: A 75-year-old female presented with a 58 mm descending thoracic aortic aneurysm (TAA) extending to the distal arch, involving the left subclavian artery (LSA) and the left common carotid artery (LCCA). The computed tomography (CT) scans underwent scrutiny by radiology and vascular teams. Nevertheless, the precise spatial relationships of the ostial origins proved to be challenging to ascertain. To address this, a patient-specific phantom of the aortic arch was fabricated utilizing an SLA printer and a biomedical resin. The thoracic endovascular aortic repair (TEVAR) procedure was simulated using fluoroscopy on the phantom to enhance procedural preparedness. Subsequently, the patient underwent a right carotid-left carotid bypass and a right carotid-left subclavian bypass. After a 24-hour interval, the patient underwent the TEVAR procedure, during which a 37 mm × 150 mm stent graft (CTAG, WL Gore and Associates, Flagstaff, AZ, USA) and a 40 mm × 200 mm stent graft (CTAG, WL Gore and Associates, Flagstaff, AZ, USA) were deployed, effectively covering the LSA and LCCA. Notably, the aneurysm exhibited complete sealing, with no indications of endoleaks or graft infoldings. At the 12-month follow-up, the patient remains in good health, with no evidence of endoleaks or any other surgery-related complication. CONCLUSION: This report showcases the successful use of a 3D-printed endovascular phantom in guiding the decision-making process during the preparation for a TEVAR procedure. The simulation played a pivotal role in selecting the appropriate stent graft, ensuring an intervention protocol optimized based on the patient-specific anatomy.


Subject(s)
Aneurysm , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Female , Humans , Aged , Endovascular Aneurysm Repair , Blood Vessel Prosthesis/adverse effects , Stents/adverse effects , Endoleak/etiology , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Treatment Outcome , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aneurysm/surgery , Retrospective Studies
2.
Macromol Rapid Commun ; 45(6): e2300611, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38158746

ABSTRACT

An ideal vascular phantom should be anatomically accurate, have mechanical properties as close as possible to the tissue, and be sufficiently transparent for ease of visualization. However, materials that enable the convergence of these characteristics have remained elusive. The fabrication of patient-specific vascular phantoms with high anatomical fidelity, optical transparency, and mechanical properties close to those of vascular tissue is reported. These final properties are achieved by 3D printing patient-specific vascular models with commercial elastomeric acrylic-based resins before coating them with thiol-based photopolymerizable resins. Ternary thiol-ene-acrylate chemistry is found optimal. A PETMP/allyl glycerol ether (AGE)/polyethylene glycol diacrylate (PEGDA) coating with a 30/70% AGE/PEGDA ratio applied on a flexible resin yielded elastic modulus, UTS, and elongation of 3.41 MPa, 1.76 MPa, and 63.2%, respectively, in range with the human aortic wall. The PETMP/AGE/PEGDA coating doubled the optical transmission from 40% to 80%, approaching 88% of the benchmark silicone-based elastomer. Higher transparency correlates with a decrease in surface roughness from 2000 to 90 nm after coating. Coated 3D-printed anatomical replicas are showcased for pre-procedural planning and medical training with good radio-opacity and echogenicity. Thiol-click chemistry coatings, as a surface treatment for elastomeric stereolithographic 3D-printed objects, address inherent limitations of photopolymer-based additive manufacturing.


Subject(s)
Polyethylene Glycols , Sulfhydryl Compounds , Humans , Sulfhydryl Compounds/chemistry , Polyethylene Glycols/chemistry , Printing, Three-Dimensional
3.
J Cardiovasc Thorac Res ; 15(3): 186-192, 2023.
Article in English | MEDLINE | ID: mdl-38028714

ABSTRACT

Hemodynamic and intravascular volume monitoring has been utilized and significantly improved thanks to the technology revolution. Goal-Directed Therapy (GDT) derived from this advanced monitoring is beneficial for complex surgeries, and it shifted the medical approaches from static therapy to more personalized functional treatments. Conventional monitoring methods such as blood pressure, heart rate, urinary output, and central venous pressure are commonly used. However, studies have shown these routine parameters often cannot precisely estimate the quality of tissue perfusion. Tissue hypoperfusion and hypoxia play a crucial role in initiating a systemic inflammatory response after prolonged surgeries, resulting in unstable hemodynamic condition of the patients. Several studies reported the importance of GDT in non-cardiac surgeries and there are few reports on cardiac surgeries. However, tissue perfusion and fluid management are more critical in complex and prolonged cardiovascular surgeries to avoid complications such as low cardiac output syndrome and renal or pulmonary dysfunction. Different advanced hemodynamic monitorings have been utilized perioperatively in cardiac surgery to help decision-making on inotrope and fluid management. In this article we present 5 cases of usefulness hemodynamic monitoring in patients who underwent cardiovascular surgeries.

SELECTION OF CITATIONS
SEARCH DETAIL
...