Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Physiol (1985) ; 96(5): 1886-93, 2004 May.
Article in English | MEDLINE | ID: mdl-14594867

ABSTRACT

Many cell types regulate their volume in response to extracellular tonicity changes through a complex series of adaptive mechanisms. Several methods that are presently used to measure cell volume changes include Coulter counters, fluorescent techniques, electronic impedance, and video microscopy. Although these methods are widely used and accepted, there are limitations associated with each technique. This paper describes a new method to measure changes in cell volume based on the principle that fluid flow within a rigid system is well determined. For this study, cos-7 cells were plated to line the inner lumen of a glass capillary and stimulated to swell or shrink by altering the osmolarity of the perfusing solution. The cell capillary was connected in series with a blank reference capillary, and differential pressure changes across each tube were monitored. The advantages of this method include 1) ability to continuously monitor changes in volume during rapid solution changes, 2) independence from cell morphology, 3) presence of physiological conditions with cell surface contacts and cell-cell interactions, 4) no phototoxic effects such as those associated with fluorescent methods, and 5) ability to report from large populations of cells. With this method, we could detect the previously demonstrated enhanced volume regulation of cells overexpressing the membrane phosphoprotein phospholemman, which has been implicated in osmolyte transport.


Subject(s)
Cytological Techniques , Kidney/cytology , Animals , COS Cells , Calibration , Cell Size , Chlorocebus aethiops , Kidney/metabolism , Membrane Proteins/metabolism , Models, Biological , Phosphoproteins/metabolism , Transducers, Pressure
2.
Electrophoresis ; 23(20): 3487-95, 2002 Oct.
Article in English | MEDLINE | ID: mdl-12412116

ABSTRACT

Silica monolithic columns suitable for implementation on microchips have been evaluated by ion-exchange capillary electrochromatography. Two different silica monoliths were created from the alkyl silane, tetramethyl orthosilicate (TMOS), by introducing a water-soluble organic polymer, poly(ethylene oxide) (PEO), with varying molecular weights into the prehydrolyzed sol. Silica monoliths created using 10 kDa PEO were found to have a much more closed gel structure with a smaller percentage of pores in the microm size range than gels created using 100 kDa PEO. Additionally, the size of the mesopores in the 100 kDa PEO monolith was 5 nm, while those in the 10 kDa PEO gel were only 3 nm. This resulted in a strong dependence of the electroosmotic flow (EOF) on the ionic strength of the background electrolyte, with substantial pore flow through the nm size pores observed in the 10 kDa PEO gel. The chromatographic performance of the monolithic columns was evaluated by ion-exchange electrochromatography, with ion-exchange sites introduced via dynamic coating with the cationic polymer, poly(diallyldimethylammonium chloride) (PDDAC). Separating a mixture of inorganic anions, the 10 kDa PEO monolithic columns showed a higher effective capacity than the 100 kDa PEO column.


Subject(s)
Chromatography, Micellar Electrokinetic Capillary/instrumentation , Anions/isolation & purification , Chromatography, Ion Exchange/instrumentation , Chromatography, Ion Exchange/methods , Chromatography, Micellar Electrokinetic Capillary/methods , Miniaturization , Molecular Weight , Osmosis , Silica Gel , Silicon Dioxide
SELECTION OF CITATIONS
SEARCH DETAIL
...