Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Geriatr Cardiol ; 13(5): 465-70, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27594877

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is associated with inflammation and endothelial dysfunction. However, the association between inflammation (as indexed by high-sensitivity C-reactive protein, hs-CRP) and endothelial function [as indexed by big endothelin-1 (ET-1)] in AF patients remains unclear. METHODS: We enrolled 128 patients with lone AF, among which 83 had paroxysmal AF, and 45 had persistent AF. Eighty-two age- and gender-matched controls of paroxysmal supraventricular tachycardia without AF history were evaluated. Plasma hs-CRP, big ET-1 levels and other clinical characteristics were compared among the groups. RESULTS: Patients with persistent AF had higher hs-CRP concentrations than those with paroxysmal AF (P < 0.05), both groups had higher hs-CRP level than controls (P < 0.05). Patients with persistent AF had higher big ET-1 level than those with paroxysmal AF, although the difference did not reach the statistical significance (P > 0.05), and both groups had higher big ET-1 levels than controls (P < 0.05). Multiple regression analyses revealed hs-CRP as an independent determinant of AF (P < 0.001). Further adjusted for big ET-1, both big ET-1 and hs-CRP were independent predictors for AF (P < 0.001), but the odds ratio for hs-CRP in predicting AF attenuated from 8.043 to 3.241. There was a positive relation between hs-CRP level and big ET-1 level in paroxysmal AF patients (r = 0.563, P < 0.05), however, the relationship in persistent AF patients was poor (r = 0.094, P < 0.05). CONCLUSIONS: Both plasma hs-CRP and big ET-1 levels are elevated in lone AF patients, and are associated with AF. In paroxysmal lone AF patients, there were significant positive correlations between plasma hs-CRP level and big ET-1 level.

2.
J Geriatr Cardiol ; 13(1): 70-4, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26918016

ABSTRACT

BACKGROUND: One of the major challenges in arrhythmogenic right ventricular cardiomyopathy (ARVC) ablation is ventricular tachycardia (VT) non-inducibility. The study aimed to assess whether fast rate (≥ 250 beats/min) right ventricular burst stimulation was useful for VT induction in patients with ARVC. METHODS: Ninety-one consecutive ARVC patients with clinical sustained VT that underwent electrophysiological study were enrolled. The stimulation protocol was implemented at both right ventricular apex and outflow tract as follows: Step A, up to double extra-stimuli; Step B, incremental stimulation with low rate (< 250 beats/min); Step C, burst stimulation with fast rate (≥ 250 beats/min); Step D, repeated all steps above with intravenous infusion of isoproterenol. RESULTS: A total of 76 patients had inducible VT (83.5%), among which 49 were induced by Step C, 15 were induced by Step B, 8 and 4 by Step A and D, respectively. Clinical VTs were induced in 60 patients (65.9%). Only two spontaneously ceased ventricular fibrillations were induced by Step C. Multivariate analysis showed that a narrower baseline QRS duration under sinus rhythm was independently associated with VT non-inducibility (OR: 1.1; 95% CI: 1.0-1.1; P = 0.019). CONCLUSION: Fast rate (≥ 250 beats/min) right ventricular burst stimulation provides a useful supplemental method for VT induction in ARVC patients.

3.
Chin Med J (Engl) ; 128(9): 1151-3, 2015 May 05.
Article in English | MEDLINE | ID: mdl-25947395

ABSTRACT

BACKGROUND: Nonfluoroscopic three-dimensional electroanatomical system is widely used nowadays, but X-ray remains indispensable for complex electrophysiology procedures. This study aimed to evaluate the value of optimized parameter setting and different projection position to reduce X-ray radiation dose rates. METHODS: From June 2013 to October 2013, 105 consecutive patients who underwent complex ablation were enrolled in the study. After the ablation, the radiation dose rates were measured by two different settings (default setting and optimized setting) with three projection positions (posteroanterior [PA] projection; left anterior oblique [LAO] 30° projection; and LAO 45° projection). The parameter of preset voltage, pulse width, critical voltage, peak voltage, noise reduction, edge enhancement, pulse rate, and dose per frame was modified in the optimized setting. RESULTS: The optimized setting reduced radiation dose rates by 87.5% (1.7 Gy/min vs. 13.6 Gy/min, P < 0.001) in PA, 87.3% (2.5 Gy/min vs. 19.7 Gy/min, P < 0.001) in LAO 30°, 85.9% (3.1 Gy/min vs. 22.1 Gy/min, P < 0.001) in LAO 45°. Increase the angle of projection position will increase the radiation dose rate. CONCLUSIONS: We can reduce X-ray radiation dose rates by adjusting the parameter setting of X-ray system. Avoiding oblique projection of large angle is another way to reduce X-ray radiation dose rates.


Subject(s)
Catheter Ablation/methods , Fluoroscopy/methods , Adult , Aged , Arrhythmias, Cardiac/surgery , Atrial Fibrillation/surgery , Electrophysiology , Female , Humans , Male , Middle Aged , Radiation Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...