Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 15(8)2022 Apr 11.
Article in English | MEDLINE | ID: mdl-35454499

ABSTRACT

An extensive numerical study was carried out due to the concern that head-sectional damage caused by corrosion poses a threat to the tensile performance of headed stud connectors. Three-dimensional finite element models of pull-out tests were established, with both material and geometric nonlinearities being considered. In particular, the concrete weak region due to bleeding was simulated. The simulation method was verified by the results of pull-out tests on two connectors with different damage degrees. Tensile performance of headed stud shear connectors of various shaft diameters (ds = 10 to 25 mm) with various damage degrees (up to 50%) was simulated. It was observed that the connector with a high damage degree exhibited low capacity and a failure closer to pull-out failure than concrete cone breakout failure. Based on the numerical results, reduction factors for quantitatively assessing the influence of head-sectional damage degree on the loading capacity and stiffness of connectors were proposed. With reference to the Concrete Capacity method, the reduction in tensile capacity of connectors with head-sectional damage was found to be caused by the decrease in the projected area of the concrete cone due to the reduction in head diameter, concrete cone angle, and embedment depth. Meanwhile, numerical results showed that the stiffness of a connector at a high embedment depth or in high strength concrete was more sensitive to head-sectional damage. It was also found that the elastic modulus of the weak region significantly affected the stiffness of connectors, while the influence of its thickness on the capacity and stiffness was insignificant.

2.
Materials (Basel) ; 13(14)2020 Jul 10.
Article in English | MEDLINE | ID: mdl-32664241

ABSTRACT

The application of fiber-reinforced polymer (FRP) bars and ultra-high performance concrete (UHPC) in the field of civil engineering is promising. An innovative FRP bar-reinforced UHPC short-ribbed bridge deck slab, with low self-weight and high structural performance, was proposed in this study. The behavior of one-way basalt FRP (BFRP) bar-reinforced UHPC slabs under concentrated load was experimentally investigated, and compared with that of a steel bar-reinforced UHPC slab. The ultimate capacity of the one-way BFRP bar-reinforced UHPC slab was 0.59 times that of the steel bar-reinforced UHPC slab, while its ductility was better. Increasing the reinforcement ratio and loading area was beneficial to the ductility of one-way BFRP bar-reinforced UHPC slabs. Moreover, the model proposed by EI-Gamal et al. was found to be suitable for evaluating the punching shear capacities of one-way BFRP bar-reinforced UHPC slabs. However, the model failed to consider the unique strain-hardening characteristics of UHPC, which led to conservative prediction.

SELECTION OF CITATIONS
SEARCH DETAIL
...