1.
JACC Clin Electrophysiol ; 7(6): 745-754, 2021 06.
Article in English | MEDLINE | ID: mdl-33516715

ABSTRACT

OBJECTIVES: This study reports resource use and economic implications of rhythm monitoring with subcutaneous cardiac rhythm monitors (SCRMs). BACKGROUND: SCRMs generate a substantial amount of data that requires timely adjudication for appropriate clinical care. Resource use for SCRM monitoring is not known. METHODS: The study included consecutive transmissions during 4 weeks from 1,811 SCRMs. Resource use was quantified by assessment of time commitment of device clinic personnel and electrophysiologists for data adjudication. Incidence and characteristics of false positive (FP) episodes were assessed. Impact of custom programming for arrhythmia detection on incidence of FP episodes and resource use was analyzed. RESULTS: A total of 1,457 transmissions (alerts = 462; full downloads = 995) were received during study period. Average device clinic personnel time for adjudication of 1 transmission was 15 ± 6 min. This totaled to 364 h spent (2.3 full-time staff) over the 4-week period, which translated into a salary cost of $12,000 U.S. dollars (USD). Average time spent by an electrophysiologist for 1 transmission was 1.5 ± 1 min and totaled to 37 h for 4 weeks, which translated into an estimated cost of $9,600 USD. Of 1,457 total transmissions, 512 (35%) represented multiple transmissions from the same patients, which resulted in no additional reimbursement. Incidence of FP episodes in the entire cohort was 50% and was variable in alert (60%) and full download (49%) (p = 0.04) transmissions. When SCRMs with manufacturer suggested nominal programming and institutional custom programming were compared, there was a reduction in FP episodes (55% vs. 16%; p = 0.01), which translated to a 34% reduction in resource use for data adjudication. CONCLUSIONS: SCRM data adjudication requires significant resources. Custom programming for SCRMs may overcome the data deluge.


Subject(s)
Defibrillators, Implantable , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Humans , Incidence , Monitoring, Physiologic
2.
J Am Heart Assoc ; 9(19): e017789, 2020 10 20.
Article in English | MEDLINE | ID: mdl-33006292

ABSTRACT

Background Atrial fibrillation (AF) driver mechanisms are obscured to clinical multielectrode mapping approaches that provide partial, surface-only visualization of unstable 3-dimensional atrial conduction. We hypothesized that transient modulation of refractoriness by pharmacologic challenge during multielectrode mapping improves visualization of hidden paths of reentrant AF drivers for targeted ablation. Methods and Results Pharmacologic challenge with adenosine was tested in ex vivo human hearts with a history of AF and cardiac diseases by multielectrode and high-resolution subsurface near-infrared optical mapping, integrated with 3-dimensional structural imaging and heart-specific computational simulations. Adenosine challenge was also studied on acutely terminated AF drivers in 10 patients with persistent AF. Ex vivo, adenosine stabilized reentrant driver paths within arrhythmogenic fibrotic hubs and improved visualization of reentrant paths, previously seen as focal or unstable breakthrough activation pattern, for targeted AF ablation. Computational simulations suggested that shortening of atrial refractoriness by adenosine may (1) improve driver stability by annihilating spatially unstable functional blocks and tightening reentrant circuits around fibrotic substrates, thus unmasking the common reentrant path; and (2) destabilize already stable reentrant drivers along fibrotic substrates by accelerating competing fibrillatory wavelets or secondary drivers. In patients with persistent AF, adenosine challenge unmasked hidden common reentry paths (9/15 AF drivers, 41±26% to 68±25% visualization), but worsened visualization of previously visible reentry paths (6/15, 74±14% to 34±12%). AF driver ablation led to acute termination of AF. Conclusions Our ex vivo to in vivo human translational study suggests that transiently altering atrial refractoriness can stabilize reentrant paths and unmask arrhythmogenic hubs to guide targeted AF driver ablation treatment.


Subject(s)
Atrial Fibrillation/etiology , Heart/physiopathology , Adenosine/pharmacology , Adult , Atrial Fibrillation/pathology , Atrial Fibrillation/physiopathology , Female , Heart/drug effects , Heart Atria/pathology , Heart Atria/physiopathology , Humans , Imaging, Three-Dimensional , Male , Microelectrodes , Middle Aged , Myocardium/pathology , Voltage-Sensitive Dye Imaging
3.
J Cardiovasc Thorac Res ; 10(2): 113-114, 2018.
Article in English | MEDLINE | ID: mdl-30116511

ABSTRACT

An ascending aortic thrombus is a rare source for embolic transient ischemic attack (TIA) or stroke without an associated aortic pathology. Here we describe a case of a patient who presented with generalized symptoms of headache and fatigue who, on subsequent work-up , was found to have an ascending aortic thrombus with no obvious associated aortic pathology, and was successfully treated with apixaban, a newer direct oral anticoagulant.

4.
Ann Thorac Surg ; 105(5): e219-e220, 2018 05.
Article in English | MEDLINE | ID: mdl-29274695

ABSTRACT

This report describes the case of a 49-year-old man with a medical history significant for congenital aortic stenosis. The patient presented with progressive shortness of breath and decreased stamina and was found to have a concentric, diminutive porcelain ascending aorta with diffuse supravalvular aortic stenosis. We describe treatment with an aortic root augmentation and Bentall procedure using hypothermic circulatory arrest.


Subject(s)
Aorta/abnormalities , Aortic Stenosis, Supravalvular/congenital , Heart Valve Prosthesis Implantation/methods , Humans , Male , Middle Aged