Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Physiol Heart Circ Physiol ; 305(2): H192-202, 2013 Jul 15.
Article in English | MEDLINE | ID: mdl-23666676

ABSTRACT

Electrical dyssynchrony leads to prestretch in late-activated regions and alters the sequence of mechanical contraction, although prestretch and its mechanisms are not well defined in the failing heart. We hypothesized that in heart failure, fiber prestretch magnitude increases with the amount of early-activated tissue and results in increased end-systolic strains, possibly due to length-dependent muscle properties. In five failing dog hearts with scars, three-dimensional strains were measured at the anterolateral left ventricle (LV). Prestretch magnitude was varied via ventricular pacing at increasing distances from the measurement site and was found to increase with activation time at various wall depths. At the subepicardium, prestretch magnitude positively correlated with the amount of early-activated tissue. At the subendocardium, local end-systolic strains (fiber shortening, radial wall thickening) increased proportionally to prestretch magnitude, resulting in greater mean strain values in late-activated compared with early-activated tissue. Increased fiber strains at end systole were accompanied by increases in preejection fiber strain, shortening duration, and the onset of fiber relengthening, which were all positively correlated with local activation time. In a dog-specific computational failing heart model, removal of length and velocity dependence on active fiber stress generation, both separately and together, alter the correlations between local electrical activation time and timing of fiber strains but do not primarily account for these relationships.


Subject(s)
Heart Failure/physiopathology , Myocardial Contraction , Myocardium/pathology , Tachycardia, Ventricular/physiopathology , Ventricular Function, Left , Animals , Biomechanical Phenomena , Cardiac Pacing, Artificial , Disease Models, Animal , Dogs , Electrocardiography , Electrophysiologic Techniques, Cardiac , Finite Element Analysis , Heart Failure/complications , Heart Failure/pathology , Hemodynamics , Magnetic Resonance Imaging , Models, Cardiovascular , Stroke Volume , Systole , Tachycardia, Ventricular/complications , Tachycardia, Ventricular/pathology , Time Factors , Ventricular Pressure
2.
Am J Physiol Heart Circ Physiol ; 301(4): H1447-55, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21784986

ABSTRACT

Recently, attention has been focused on comparing left ventricular (LV) endocardial (ENDO) with epicardial (EPI) pacing for cardiac resynchronization therapy. However, the effects of ENDO and EPI lead placement at multiple sites have not been studied in failing hearts. We hypothesized that differences in the improvement of ventricular function due to ENDO vs. EPI pacing in dyssynchronous (DYSS) heart failure may depend on the position of the LV lead in relation to the original activation pattern. In six nonfailing and six failing dogs, electrical DYSS was created by atrioventricular sequential pacing of the right ventricular apex. ENDO was compared with EPI biventricular pacing at five LV sites. In failing hearts, increases in the maximum rate of LV pressure change (dP/dt; r = 0.64), ejection fraction (r = 0.49), and minimum dP/dt (r = 0.51), relative to DYSS, were positively correlated (P < 0.01) with activation time at the LV pacing site during ENDO but not EPI pacing. ENDO pacing at sites with longer activation delays led to greater improvements in hemodynamic parameters and was associated with an overall reduction in electrical DYSS compared with EPI pacing (P < 0.05). These findings were qualitatively similar for nonfailing hearts. Improvement in hemodynamic function increased with activation time at the LV pacing site during ENDO but not EPI pacing. At the anterolateral wall, end-systolic transmural function was greater with local ENDO compared with EPI pacing. ENDO pacing and intrinsic activation delay may have important implications for management of DYSS heart failure.


Subject(s)
Cardiac Pacing, Artificial/methods , Endocardium/physiology , Heart Failure/physiopathology , Heart Failure/therapy , Heart/physiology , Animals , Aortic Valve/physiology , Biomechanical Phenomena , Cineradiography , Dogs , Electrocardiography , Electrodes, Implanted , Heart Ventricles , Hemodynamics/physiology , In Vitro Techniques , Mitral Valve/physiology , Paraffin Embedding , Tachycardia/physiopathology , Ventricular Function, Left/physiology , Ventricular Function, Right/physiology
3.
Article in English | MEDLINE | ID: mdl-19963818

ABSTRACT

Here we describe new computational models of cardiac electromechanics starting from the cellular scale and building to the tissue, organ and system scales. We summarize application to human genetic diseases (LQT1 and LQT3) and to modeling of congestive heart failure.


Subject(s)
Heart Failure/physiopathology , Heart/physiopathology , Mutation , Algorithms , Computer Simulation , Electrophysiology/methods , Equipment Design , Heart Conduction System , Humans , Long QT Syndrome , Models, Cardiovascular , Models, Genetic , Muscle Cells/pathology , Myocardial Contraction , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...