Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Arthroplasty ; 29(9): 1863-70, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24845717

ABSTRACT

Aseptic loosening of total knee arthroplasty (TKA) components is the foremost cause of implant failure in the long term. While tibial component loosening is of primary concern, femoral loosening may become a clinical problem due to younger, more active patients seeking TKA, and also high-flexion designs. In this study, we analyzed the fixation for 19 non-revised, postmortem retrieved, femoral components of TKA with time in service ranging from 1 to 22 years. We found that the average total contact fraction for cemented components was 9.5% and had a power law response (decrease) with years in service. The average initial interdigitation depth was 0.7mm, and the average current interdigitation depth was 0.13mm. Loss of interdigitation was 81%. Over all, minimal fixation seems necessary for long-term success of TKA femoral components.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Femur/surgery , Knee Prosthesis/adverse effects , Osseointegration , Prosthesis Failure/etiology , Aged , Aged, 80 and over , Bone Cements/therapeutic use , Cadaver , Female , Humans , Male , Metals , Middle Aged , Prosthesis Design , Range of Motion, Articular , Tibia/surgery
2.
J Biomech ; 47(2): 518-25, 2014 Jan 22.
Article in English | MEDLINE | ID: mdl-24275439

ABSTRACT

A multi-well fluid loading (MFL) system was developed to deliver oscillatory subphysiologic to supraphysiologic fluid shear stresses to cell monolayers in vitro using standard multi-well culture plates. Computational fluid dynamics modeling with fluid-structure interactions was used to quantify the squeeze film fluid flow between an axially displaced piston and the well plate surface. Adjusting the cone angle of the piston base modulated the fluid pressure, velocity, and shear stress magnitudes. Modeling results showed that there was near uniform fluid shear stress across the well with a linear drop in pressure across the radius of the well. Using the MFL system, RAW 264.7 osteoclastic cells were exposed to oscillatory fluid shear stresses of 0, 0.5, 1.5, 4, 6, and 17 Pa. Cells were loaded 1 h per day at 1 Hz for two days. Compared to sub-physiologic and physiologic levels, supraphysiologic oscillatory fluid shear induced upregulation of osteoclastic activity as measured by tartrate-resistant acid phosphatase activity and formation of mineral resorption pits. Cell number remained constant across all treatment groups.


Subject(s)
Hydrodynamics , Osteoclasts/physiology , Stress, Mechanical , Acid Phosphatase/metabolism , Acid Phosphatase/physiology , Animals , Bone Resorption/enzymology , Bone Resorption/physiopathology , Cells, Cultured , Isoenzymes/metabolism , Isoenzymes/physiology , Mice , Osteoclasts/cytology , Osteoclasts/enzymology , Tartrate-Resistant Acid Phosphatase , Up-Regulation/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...