Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 79(15): 5980-6, 2007 Aug 01.
Article in English | MEDLINE | ID: mdl-17590013

ABSTRACT

Microcystins (MCs) are a growing problem in drinking water supplies worldwide. Common analytical techniques used to determine MC concentrations have several shortcomings, including extensive sample handling and lengthy analysis times. A simple, rapid method for quantitation of MCs by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is presented. Four potential internal standards were tested, including an 15N-labeled MC. For MC-LR in mixed standard solutions, a linear range of 0.11-5.0 microM (R2 = 0.98) was achieved, with a method detection limit (MDL) of 0.015 microM. Matrix effects due to extracted cell components decreased the MC-LR linear range slightly to 0.19-5.0 microM (R2 = 0.99), with MDL = 0.058 microM. Extensive analysis of possible internal standards indicates that nodularin was preferred over [15N]10-microcystin-YR or angiotensin I. The ionization efficiency and analyte-analyte suppression for four MCs of varying polarity are presented; the three polar congeners exhibited good ionization efficiency and acceptable levels of analyte-analyte suppression. These results indicate that MALDI-TOF MS represents a viable alternative for the quantitative measurement of MCs in field samples.


Subject(s)
Bacterial Toxins/analysis , Marine Toxins/analysis , Microcystins/analysis , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Water Microbiology , Water Supply/analysis , Angiotensin I/analysis , Cyanobacteria Toxins , Nitrogen Isotopes , Peptides, Cyclic/analysis , Reproducibility of Results , Sensitivity and Specificity
2.
Rapid Commun Mass Spectrom ; 21(5): 699-706, 2007.
Article in English | MEDLINE | ID: mdl-17279604

ABSTRACT

A novel method for simplifying adduct patterns to improve the detection and identification of peptide toxins using matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry is presented. Addition of 200 microM zinc sulfate heptahydrate (ZnSO(4) . 7H(2)O) to samples prior to spotting on the target enhances detection of the protonated molecule while suppressing competing adducts. This produces a highly simplified spectrum with the potential to enhance quantitative analysis, particularly for complex samples. The resulting improvement in total signal strength and reduction in the coefficient of variation (from 31.1% to 5.2% for microcystin-LR) further enhance the potential for sensitive and accurate quantitation. Other potential additives tested, including 18-crown-6 ether, alkali metal salts (lithium chloride, sodium chloride, potassium chloride), and other transition metal salts (silver chloride, silver nitrate, copper(II) nitrate, copper(II) sulfate, zinc acetate), were unable to achieve comparable results. Application of this technique to the analysis of several microcystins, potent peptide hepatotoxins from cyanobacteria, is illustrated.


Subject(s)
Bacterial Toxins/chemistry , Cyanobacteria/chemistry , Microcystins/chemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Bacterial Toxins/metabolism , Cyanobacteria/metabolism , Marine Toxins , Metals, Alkali/chemistry , Microcystins/metabolism , Transition Elements/chemistry , Zinc Sulfate/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...