Bone Jt Open ; 5(6): 514-523, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38910515

ABSTRACT

Aims: In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component. Methods: Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years). Results: In the DM group, two (3.8%) patients underwent further surgery: one (1.9%) for dislocation and one (1.9%) for infection. In the AR group, four (9.8%) underwent further procedures: two (4.9%) for loosening of the acetabular component and two (4.9%) following dislocations. There were no other dislocations in either group. In the DM group, operating time (68.4 vs 101.5 mins, p < 0.001), postoperative drop in haemoglobin (16.6 vs 27.8 g/L, p < 0.001), and length of stay (1.8 vs 2.4 days, p < 0.001) were significantly lower. There was a significant reduction in serum metal ions postoperatively in both groups (p < 0.001), although there was no difference between groups for this reduction (p = 0.674 (cobalt); p = 0.186 (chromium)). Conclusion: In selected patients with Birmingham MoM hips, where the acetabular component is well-fixed and in a satisfactory position with no surface damage, the metal head can be exchanged for polyethylene ADM/MDM bearings with retention of the acetabular prosthesis. This presents significant benefits, with a shorter procedure and a lower risk of complications.

2.
Hip Int ; 34(2): 187-193, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37694894

ABSTRACT

AIMS: This study reports on the Exeter-Trident total hip arthroplasty (THA) using an alumina ceramic-on-ceramic bearing with 10-year clinical and radiographic follow-up. PATIENTS AND METHODS: Between January 2001 and January 2006, 275 THAs were performed. Mean age at surgery was 52.7 (17-86) years, with 84 patients (33.6%) aged <50 years. The primary outcome was all-cause construct survival at minimum 10 years. Secondary outcomes included functional and noise scores. Radiographs were compared between baseline and latest follow-up and assessed for component loosening, migration and lysis. RESULTS: No patient was lost to follow-up. Mean follow-up for surviving patients was 12.5 (9.5-15.6) years. Kaplan-Meier survival for all-cause revision was 94.0% (95% CI, 90.5-97.5) at 14.3 years. 2 patients had a femoral component fracture. All scores improved significantly at latest follow-up. HSS-NQ for 247 hips (90.2%) at mean 9.1 (7.0-14.4) years post implantation showed most hips (93.1%) reported no more than occasional noise. At minimum 5 years, radiolucency around the acetabular component was observed in 2 hips (0.8%), and lysis at the interface in 1 hip (0.4%). On the femoral side, endosteal lysis was observed in 7 hips. CONCLUSIONS: The Exeter-Trident THA with alumina ceramic-on-ceramic bearings performed well in this population. Patients are at low risk of revision in the first decade. However, there is a small risk of stem fracture as a late complication and some patients experience significant noise.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Hip Prosthesis , Humans , Middle Aged , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Treatment Outcome , Prosthesis Failure , Reoperation , Prosthesis Design , Ceramics , Aluminum Oxide , Femoral Fractures/surgery , Follow-Up Studies , Hip Joint/surgery
3.
Acta Orthop Belg ; 89(2): 340-347, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37924552

ABSTRACT

The aim is to review clinical and radiological outcomes for all cases of primary and revision THA, combining a cemented stem (Exeter V40) with a dual mobility component from a different manufacturer (SERF Novae), to evaluate whether concerns regarding mixing components from different manufacturers are justified. We identified 72 hip replacements performed between May 2010 and December 2015 using the SERF Novae dual mobility cup with an Exeter V40 stem, the majority of which were cemented (90%) and revisions (58%). Patients were evaluated clinically and radiologically at a minimum of two years. There were five (6.9%) dislocations; three (4.2%) requiring revision - one of which was an intra-prosthetic disarticulation and two infections. No cases were lost to follow-up and 49 surviving cases were reviewed at a mean of 4.0 (range 1.8-8.1) years following surgery. Pain and functional outcome scores all improved. There were no radiological failures and no revisions for aseptic loosening of stem or cup. The combination of Exeter cemented stem with a dual mobility bearing from a different manufacturer results in acceptable short-term outcomes in terms of hip stability, revision rates and patient-reported measures.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Prosthesis Design , Prosthesis Failure , Retrospective Studies , Reoperation , Follow-Up Studies
4.
Bone Joint J ; 105-B(10): 1038-1044, 2023 Oct 01.
Article in English | MEDLINE | ID: mdl-37777212

ABSTRACT

Aims: The aim of this study was to perform a systematic review of the evidence for the use of intraoperative cell salvage in patients undergoing revision hip arthroplasty, and specifically to analyze the available data in order to quantify any associated reduction in the use of allogenic blood transfusion, and the volume which is used. Methods: An electronic search of MEDLINE (PubMed), Embase, Scopus, and the Cochrane Library was completed from the date of their inception to 24 February 2022, using a search strategy and protocol created in conjunction with the PRISMA statement. Inclusion criteria were patients aged > 18 years who underwent revision hip arthroplasty when cell salvage was used. Studies in which pre-donated red blood cells were used were excluded. A meta-analysis was also performed using a random effects model with significance set at p = 0.05. Results: Of the 283 studies which were identified, 11 were included in the systematic review, and nine in the meta-analysis. There was a significant difference (p < 0.001) in the proportion of patients requiring allogenic transfusion between groups, with an odds ratio of 0.331 (95% confidence interval (CI) 0.165 to 0.663) associated with the use of cell salvage. For a total of 561 patients undergoing revision hip arthroplasty who were treated with cell salvage, 247 (44.0%) required allogenic transfusion compared with 418 of 643 patients (65.0%) who were treated without cell salvage. For those treated with cell salvage, the mean volume of allogenic blood which was required was 1.95 units (390 ml) per patient (0.7 to 4.5 units), compared with 3.25 units (650 ml) per patient (1.2 to 7.0 units) in those treated without cell salvage. The mean difference of -1.91 units (95% CI -4.0 to 0.2) in the meta-analysis was also significant (p = 0.003). Conclusion: We found a a significant reduction in the need for allogenic blood transfusion when cell salvage was used in patients undergoing revision hip arthroplasty, supporting its routine use in these patients. Further research is required to determine whether this effect is associated with types of revision arthroplasty of differing complexity.


Subject(s)
Arthroplasty, Replacement, Hip , Humans , Arthroplasty, Replacement, Hip/methods , Blood Transfusion
5.
Cureus ; 15(3): e36464, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37090282

ABSTRACT

BACKGROUND: Venous thromboembolism (VTE) is a potentially reducible cause of morbidity and mortality in patients undergoing elective hip arthroplasty surgery. The balance of post-operative VTE prophylaxis and risk of post-operative haemorrhage remains at the forefront of surgeon's mind. The National Institute for Health and Care Excellence (NICE) published updated guidelines in 2018 which recommend the use of both mechanical and pharmacological methods in patients undergoing elective total hip arthroplasty (THA). OBJECTIVES: The aim of this study was to present the symptomatic VTE incidence in 8,885 patients who underwent THA between January 1998 and March 2018 with Aspirin as the primary agent for pharmacological thromboprophylaxis. Intermittent calf compression stockings are routinely used from the time of surgery until mobilization (usually the following day) with prophylactic doses of low molecular weight heparin (LMWH) during inpatient stay (from 2005 onwards) and then Aspirin 150mg once daily for six weeks on hospital discharge (or Aspirin only prior to 2005), with use of other therapies occasionally as required. METHODS: Analysis of prospective data collection from consecutive patients at a single institution undergoing THA was performed with the incidence of symptomatic deep vein thrombosis (DVT) and pulmonary embolism (PE) occurring within six months of the index operation as the primary outcome measure. Ninety-day all-cause mortality of this cohort of patients was also analysed. RESULTS: 8,885 patients were reviewed. This included 7230 primary, 224 complex primary and 1431 revision cases. The overall incidence of symptomatic VTE after elective THA was 1.11% (99/8885) - with the incidence of symptomatic DVT of 0.59% (52/8885) and the incidence of symptomatic PE of 0.53% (47/8885). There was no significant difference (χ2 test, p=0.239) in the symptomatic VTE incidence between primary (1.20% - 89/7230), complex primary (0.89% - 2/224) and revision cases (0.70% - 10/1431). The 90-day all-cause mortality was 0.88% (78/8885). Cardiovascular and respiratory disease were the main causes of death following surgery. Only 0.03% of deaths (n= 3) within 90 days of index surgery were due to PE. There was no significant difference (p=0.327) in length of stay (and hence amount of pharmacologic prophylaxis with LMWH received by patients before commencement of Aspirin) with the average length of stay for those patients who did not suffer a VTE of 6.8 days compared with 7.6 days for those who did suffer a VTE. CONCLUSION: Our results support the use of aspirin as an effective form of prophylaxis against symptomatic VTE following THA in contradiction to NICE and American Academy of Orthopaedic Surgery (AAOS) recommendations. It is not associated with an increased incidence in symptomatic DVT, PE or death compared to other published studies. The fact that it is inexpensive, readily available, requires no monitoring and does not pose an increased risk of bleeding are other advantages of using aspirin for VTE prophylaxis.

6.
J Arthroplasty ; 38(7 Suppl 2): S38-S44, 2023 07.
Article in English | MEDLINE | ID: mdl-37086929

ABSTRACT

BACKGROUND: Periprosthetic fractures following elective and nonelective hip arthroplasty remain one of the most common modes of early failure. METHODS: This symposium will explore the current role of cemented fixation and periprosthetic fracture, focusing on history and rationale for cemented stem fixation, registry data, and other potential advantages of cemented stem fixation. A meticulous and methodical surgical technique of cemented stem fixation is paramount to the success and will be thoroughly discussed. RESULTS: The role of stem fixation, and its effect on periprosthetic fracture is well-documented in the literature. Yet despite this, the utilization of cemented stem fixation remains low in the United States. This paradox is multifactorial. CONCLUSION: In addition to a notable reduction in the risk of periprosthetic femur fractures, cemented stem fixation has numerous other advantages and is reproducible with a methodical surgical technique.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Hip Prosthesis , Periprosthetic Fractures , Humans , United States , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Prosthesis Design , Femur/surgery , Reoperation , Femoral Fractures/surgery
7.
Bone Jt Open ; 3(5): 423-431, 2022 May.
Article in English | MEDLINE | ID: mdl-35549448

ABSTRACT

AIMS: The aim of this modified Delphi process was to create a structured Revision Hip Complexity Classification (RHCC) which can be used as a tool to help direct multidisciplinary team (MDT) discussions of complex cases in local or regional revision networks. METHODS: The RHCC was developed with the help of a steering group and an invitation through the British Hip Society (BHS) to members to apply, forming an expert panel of 35. We ran a mixed-method modified Delphi process (three rounds of questionnaires and one virtual meeting). Round 1 consisted of identifying the factors that govern the decision-making and complexities, with weighting given to factors considered most important by experts. Participants were asked to identify classification systems where relevant. Rounds 2 and 3 focused on grouping each factor into H1, H2, or H3, creating a hierarchy of complexity. This was followed by a virtual meeting in an attempt to achieve consensus on the factors which had not achieved consensus in preceding rounds. RESULTS: The expert group achieved strong consensus in 32 out of 36 factors following the Delphi process. The RHCC used the existing Paprosky (acetabulum and femur), Unified Classification System, and American Society of Anesthesiologists (ASA) classification systems. Patients with ASA grade III/IV are recognized with a qualifier of an asterisk added to the final classification. The classification has good intraobserver and interobserver reliability with Kappa values of 0.88 to 0.92 and 0.77 to 0.85, respectively. CONCLUSION: The RHCC has been developed through a modified Delphi technique. RHCC will provide a framework to allow discussion of complex cases as part of a local or regional hip revision MDT. We believe that adoption of the RHCC will provide a comprehensive and reproducible method to describe each patient's case with regard to surgical complexity, in addition to medical comorbidities that may influence their management. Cite this article: Bone Jt Open 2022;3(5):423-431.

8.
Bone Jt Open ; 3(3): 196-204, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35253478

ABSTRACT

AIMS: The aim of this study was to assess medium-term improvements following total hip arthroplasty (THA), and to evaluate what effect different preoperative Oxford Hip Score (OHS) thresholds for treatment may have on patients' access to THA and outcomes. METHODS: Patients undergoing primary THA at our institution with an OHS both preoperatively and at least four years postoperatively were included. Rationing thresholds were explored to identify possible deprivation of OHS improvement. RESULTS: Overall, 2,341 patients were included. Mean OHS was 19.7 (SD 8.2) preoperatively and 39.7 (SD 9.8) at latest follow-up. An improvement of at least eight-points, the minimally important change (MIC), was seen in 2,072 patients (88.5%). The mean improvement was 20.0 points (SD 10.5). If a rationing threshold of OHS of 20 points had been enforced, 90.8% of those treated would have achieved the MIC, but only 54.3% of our cohort would have had access to surgery; increasing this threshold to 32 would have enabled 89.5% of those treated to achieve the MIC while only depriving 6.5% of our cohort. The 'rationed' group of OHS > 20 had significantly better OHS at latest follow-up (42.6 vs 37.3; p < 0.001), while extending the rationing threshold above 32 showed postoperative scores were more significantly affected by the ceiling effect of the OHS. CONCLUSION: The OHS was not designed as a tool to ration healthcare, but if it had been used at our institution for this cohort, applying an OHS threshold of 20 to routine THA access would have excluded nearly half of patients from having a THA; a group in which over 85% had a significant improvement in OHS. Where its use for rationing is deemed necessary, use of a higher threshold may be more appropriate to ensure a better balance between patient access to treatment and chances of achieving good to excellent outcomes. Cite this article: Bone Jt Open 2022;3(3):196-204.

9.
Bone Joint J ; 103-B(1): 71-78, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33380191

ABSTRACT

AIMS: Periprosthetic fractures (PPFs) around cemented taper-slip femoral prostheses often result in a femoral component that is loose at the prosthesis-cement interface, but where the cement-bone interface remains well-fixed and bone stock is good. We aim to understand how best to classify and manage these fractures by using a modification of the Vancouver classification. METHODS: We reviewed 87 PPFs. Each was a first episode of fracture around a cemented femoral component, where surgical management consisted of revision surgery. Data regarding initial injury, intraoperative findings, and management were prospectively collected. Patient records and serial radiographs were reviewed to determine fracture classification, whether the bone cement was well fixed (B2W) or loose (B2L), and time to fracture union following treatment. RESULTS: In total, 47 B2W fractures (54.0%) and one B3 fracture (1.1%) had cement that remained well-fixed at the cement-bone interface. These cases were treated with cement-in-cement (CinC) revision arthroplasty. Overall, 43 fractures with follow-up united, and two patients sustained further fractures secondary to nonunion and required further revision surgery. A total of 19 B2L fractures (21.8%) and 19 B3 fractures (21.8%) had cement that was loose at the cement-bone interface. These cases were managed by revision arthroplasty with either cemented or uncemented femoral components, or proximal femoral arthroplasty. One case could not be classified. CONCLUSION: We endorse a modification of the original Vancouver system to include a subclassification of B2 fractures around cemented femoral prostheses to include B2W (where cement is well-fixed to bone) and B2L (where the cement is loose). Fractures around taper-slip design stems are more likely to fracture in a B2W pattern compared to fractures around composite beam design stems which are more likely to fracture in a B2L pattern. B2W fractures can reliably be managed with CinC revision. Cite this article: Bone Joint J 2021;103-B(1):71-78.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures/classification , Periprosthetic Fractures/classification , Adult , Aged , Bone Cements , Female , Femoral Fractures/surgery , Fracture Fixation/methods , Hip Prosthesis , Humans , Male , Middle Aged , Periprosthetic Fractures/surgery , Prosthesis Failure , Reoperation , Surface Properties
10.
J Arthroplasty ; 35(4): 1042-1047, 2020 04.
Article in English | MEDLINE | ID: mdl-31882346

ABSTRACT

BACKGROUND: There is variable evidence regarding survivorship beyond 20 years of total hip arthroplasties in young patients. We report the long-term results of the Exeter cemented hip system in patients ≤50 years at minimum of 20 years. METHODS: Clinical and radiological outcomes of 130 consecutive total hip arthroplasties in 107 patients aged 50 years or younger at primary operation were reviewed; 77% had a diagnosis other than osteoarthritis. All patients were followed at 5-year intervals, no patients were lost to follow-up, and the status of every implant is known. RESULTS: Mean age at surgery was 41.8 (17-50) years. Mean follow-up was 22.0 (20.0-26.1) years. There were 79 hips surviving, 14 hips (11 patients) deceased, and 37 hips revised. Reasons for revision: 29 hips for aseptic cup loosening (26 stems revised using cement-in-cement, three left in-situ); three stems for femoral osteolysis, two related to acetabular polyethylene wear (14.1 and 17.0 years), one with Gaucher's disease (21.1 years); one broken stem (12.9 years); one cup for instability (4.3 years-stem revised using cement-in-cement); and two hips with infection (8.5 and 23.8 years). There were no cases of aseptic loosening of the Exeter stem. There were no radiologically loose stems although eight patients had radiological evidence of loosening of the cemented cup. Survivorship at 22 years was 74.9% for revision for all causes and 96.3% for revision of the stem for aseptic loosening or lysis. CONCLUSION: The Exeter cemented stem has excellent survivorship at minimum 20 years in young patients. Acetabular component survivorship was less favorable, but the advent of highly cross-linked polyethylene may improve this in the long term.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Adult , Arthroplasty, Replacement, Hip/adverse effects , Follow-Up Studies , Humans , Middle Aged , Prosthesis Design , Prosthesis Failure , Reoperation , Treatment Outcome
11.
J Arthroplasty ; 34(7S): S297-S301, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31000404

ABSTRACT

BACKGROUND: Cement-in-cement femoral revision is a proven technique in revision total hip arthroplasty, with excellent results reported using standard-sized Exeter stems. The Exeter 44/00/125 short revision stem was introduced in 2004 to facilitate cement-in-cement revision. The stem is 25-mm shorter and has a slimmer body than standard stems to facilitate adjustment of depth of insertion and stem version. It is not known if this change in stem size affects its long-term performance. We therefore reviewed the outcome of all Exeter short revision stems used for cement-in-cement revision in our unit, with a minimum of 5 years of follow-up. METHOD: One hundred sixty-six cases were performed between 2004 and 2010. Mean follow-up of surviving patients was 8.1 years (range 5.0-11.7). The fate of all 166 hips were known and included in the survival analysis. RESULTS: Median clinical scores improved significantly. Sixteen hips required re-revision (infection 6, loose cup 3, periprosthetic fracture 3, instability 2, stem fracture with chronic infection 1, and pain 1). Kaplan-Meier survival analysis at 10 years revealed 100% survival for aseptic stem loosening, 96.8% survival for stem failure, and 88.9% survival for all causes. CONCLUSION: The Exeter short revision stem performed as well as standard length stems for cement-in-cement revision in this the largest and longest review of their use. Larger registry-based studies may provide additional information on the performance of this stem.


Subject(s)
Bone Cements , Hip Prosthesis , Reoperation/instrumentation , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip , Female , Femur/surgery , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Pain/surgery , Periprosthetic Fractures/surgery , Prosthesis Design , Prosthesis Failure , Reoperation/methods , Survival Analysis
12.
Acta Orthop ; 90(3): 214-219, 2019 06.
Article in English | MEDLINE | ID: mdl-30838914

ABSTRACT

Background and purpose - No difference in outcome has been demonstrated comparing cemented taper-slip and composite beam designs in short-term randomised trials; we assessed outcome differences using a registry analysis. Patients and methods - All cemented stems with > 100 implantations were identified in the National Joint Registry of England and Wales from April 1, 2003 to September 31, 2013 and categorised as taper-slip or composite beam. Survival analyses using Kaplan-Meier and Cox regression were performed. Results - We identified 292,987 cemented arthroplasties, of which 16% (47,586) were composite beam stems, with taper-slip stems making up the remainder (n = 245,401). There was a statistically significant increased chance of revision in the composite beam group compared with the taper-slip group (1.7% vs 1.3%, p < 0.001) but statistically no significant differences of survival estimates (p = 0.06). When the 2 groups were segregated to delineate the most implanted model in each category, the differences became more profound with the most implanted taper-slip stem (Exeter V40) showing statistically and clinically significant superior 8-year survival: 97.9% compared with 97.6% for all other taper-slip; 97.5% for the most implanted composite beam (Charnley cemented stem); and 97.7% for all other composite beam. Interpretation - There was an increased incidence of revision for composite beam stems. The most implanted taper-slip stem demonstrated significant survival advantage vs. all other stems.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis/statistics & numerical data , Prosthesis Failure , Prosthesis-Related Infections/epidemiology , Reoperation/statistics & numerical data , Aged , Cementation , Cohort Studies , England/epidemiology , Female , Humans , Kaplan-Meier Estimate , Male , Proportional Hazards Models , Prosthesis Design , Retrospective Studies , Treatment Outcome , Wales/epidemiology
13.
J Arthroplasty ; 32(4): 1318-1322, 2017 04.
Article in English | MEDLINE | ID: mdl-27843041

ABSTRACT

BACKGROUND: Between 1991 and 2008, approximately 80 cases of fracture (neck or stem) have been reported. This study aimed at determining factors predisposing to implant fracture. METHODS: Clinical, surgical, radiological, and retrieval data were collated. Risk factors associated with fracture were categorized to patient related (weight and activity levels), surgical related (poor medial support, component size, and placement), and anatomic/implant related (head size/offset). RESULTS: Data was available on 60 patients (32 stem and 28 neck fractures). Mean patient age at fracture was similar for both neck and stem fractures (69 years, 67 years, respectively). Also, 77% neck and 52% stem fractures occurred in men. Mean weight was 107 kg in neck and 96.5 kg in stem fractures with 68% neck and 38% stem fractures either obese or morbidly obese. Mean time to fracture was 78 months (range, 36-144 months) for neck and 76 months (range, 2-155 months) for stem fractures. 44#2 and 44#3 were the most common sizes associated with neck fractures. Stem fractures occurred more commonly (84%) in the smaller sizes (35.5 to 44#1). Elongated femoral heads were used in 69% neck and 14% stem fractures. CONCLUSION: Neck fractures were most commonly associated with patient-related (increased weight and activity) and implant-related (use of an elongated femoral head) factors. Stem fractures were most commonly associated with correctable surgical-related causes, predominantly secondary to stem undersizing or inadequate medial support (84%).


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Prosthesis Failure/etiology , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/instrumentation , Equipment Failure Analysis , Female , Femur Head/surgery , Hip Prosthesis/statistics & numerical data , Humans , Joint Prosthesis , Male , Middle Aged , Obesity, Morbid/complications , Retrospective Studies , Risk Factors , Time Factors
14.
J Orthop Surg (Hong Kong) ; 24(3): 312-316, 2016 12.
Article in English | MEDLINE | ID: mdl-28031497

ABSTRACT

PURPOSE: To use a 3-dimensional computed tomography (CT) bone database to evaluate the risk of distal contact between the rasp tip and the endosteal cortical bone. METHODS: Using a 3-dimensional CT bone database, the rasps for Exeter stems of 125 mm in length and body size 1, with a femoral offset of 37.5, 44, or 50 mm were compared with those for Exeter stems of 150 mm in length and same body size with the corresponding femoral offset. Rasp geometry was determined using an engineering drawing software. RESULTS: Of the 631 femurs in the database, 238 (187 Caucasian and 51 Asian) were of appropriate femoral offset and proximal body size to receive a stem with an offset of 37.5, 44, or 50 mm. Of these, 145 (115 Caucasian and 30 Asian) femurs were of champagne-flute type; the prevalence was comparable between the 2 populations (61% vs. 59%, p=0.729). When using the 150-mm rasp, 70 (55 Caucasian and 15 Asian) of the 238 femurs had distal contact between the rasp and femoral cortex; the prevalence was comparable between the 2 populations (29% vs. 29%, relative risk=1.0, p=1.0). Distal contact between the rasp and femoral cortex occurred more commonly in champagne-flute-type femurs than other femurs in the anteroposterior plane (28% [41/145] vs. 2% [2/93], relative risk=13.1, p<0.001) and in the mediolateral plane (27% [39/145] vs. 14% [13/93], relative risk=1.92, p=0.019). When using the 125-mm rasp, only one femur (with a canal flare index of 4.52) had distal contact in the mediolateral plane with an offset of 37.5 mm. Distal contact between the rasp and femoral cortex occurred more often with the 150-mm rasp than the 125-mm rasp in both planes (p<0.001). CONCLUSION: The use of a shorter stem may enhance anatomic fit in patients with a narrow femoral canal and prevent distal contact between the rasp and femoral cortex.


Subject(s)
Arthroplasty, Replacement, Hip , Cortical Bone/diagnostic imaging , Femur/diagnostic imaging , Hip Prosthesis , Imaging, Three-Dimensional , Tomography, X-Ray Computed , Adolescent , Adult , Aged , Aged, 80 and over , Asian People , Cortical Bone/surgery , Databases, Factual , Female , Femur/surgery , Humans , Male , Middle Aged , Risk Assessment , White People , Young Adult
15.
J Arthroplasty ; 29(9): 1827-34, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24857335

ABSTRACT

Mortality following hip arthroplasty is affected by a large number of confounding variables each of which must be considered to enable valid interpretation. Relevant variables available from the 2011 NJR data set were included in the Cox model. Mortality rates in hip arthroplasty patients were lower than in the age-matched population across all hip types. Age at surgery, ASA grade, diagnosis, gender, provider type, hip type and lead surgeon grade all had a significant effect on mortality. Schemper's statistic showed that only 18.98% of the variation in mortality was explained by the variables available in the NJR data set. It is inappropriate to use NJR data to study an outcome affected by a multitude of confounding variables when these cannot be adequately accounted for in the available data set.


Subject(s)
Arthroplasty, Replacement, Hip/mortality , Osteoarthritis, Hip/mortality , Osteoarthritis, Hip/surgery , Registries/statistics & numerical data , Registries/standards , Aged , Aged, 80 and over , Bone Cements/therapeutic use , Confounding Factors, Epidemiologic , Female , Hip Injuries/mortality , Hip Injuries/surgery , Humans , Male , Middle Aged , Osteotomy/mortality , Proportional Hazards Models , Reoperation/mortality , Risk Factors , United Kingdom/epidemiology
16.
J Arthroplasty ; 29(9): 1813-8, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24851790

ABSTRACT

Periprosthetic joint infection (PJI) after THA is a major complication with an incidence of 1%-3%. We report our experiences with a technique using a custom-made articulating spacer (CUMARS) at the first of two-stage treatment for PJI. This technique uses widely available all-polyethylene acetabular components and the Exeter Universal stem, fixed using antibiotic loaded acrylic cement. Seventy-six hips were treated for PJI using this technique. Performed as the first of a two-stage procedure, good functional results were commonly seen, leading to postponing second stage indefinitely with retention of the CUMARS prosthesis in 34 patients. The CUMARS technique presents an alternative to conventional spacers, using readily available components that are well tolerated, allowing weight bearing and mobility, and achieving comparable eradication rates.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Polyethylene , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/surgery , Acetabulum/surgery , Adult , Aged , Aged, 80 and over , Bone Cements/therapeutic use , Debridement/methods , Device Removal , Female , Follow-Up Studies , Hip Joint/surgery , Humans , Male , Middle Aged , Reoperation , Retrospective Studies , Treatment Outcome
17.
J Arthroplasty ; 28(8): 1394-400, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23523217

ABSTRACT

Between 1995 and 2003, 129 cemented primary THAs were performed using full acetabular impaction grafting to reconstruct acetabular deficiencies. These were classified as cavitary in 74 and segmental in 55 hips. Eighty-one patients were reviewed at mean 9.1 (6.2-14.3) years post-operatively. There were seven acetabular component revisions due to aseptic loosening, and a further 11 cases that had migrated >5mm or tilted >5° on radiological review - ten of which reported no symptoms. Kaplan-Meier analysis of revisions for aseptic loosening demonstrates 100% survival at nine years for cavitary defects compared to 82.6% for segmental defects. Our results suggest that the medium-term survival of this technique is excellent when used for purely cavitary defects but less predictable when used with large rim meshes in segmental defects.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Bone Transplantation/methods , Hip Dislocation/surgery , Osteoarthritis, Hip/surgery , Spondylitis, Ankylosing/surgery , Adult , Aged , Aged, 80 and over , Bone Cements , Female , Follow-Up Studies , Hip Joint/diagnostic imaging , Hip Joint/surgery , Hip Prosthesis , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Prosthesis Failure , Radiography , Retrospective Studies , Treatment Outcome
18.
J Orthop Surg (Hong Kong) ; 20(3): 316-21, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23255637

ABSTRACT

PURPOSE: To compare radiological records of 90 consecutive patients who underwent cemented total hip arthroplasty (THA) with or without use of the Rim Cutter to prepare the acetabulum. METHODS: The acetabulum of 45 patients was prepared using the Rim Cutter, whereas the device was not used in the other 45 patients. Postoperative radiographs were evaluated using a digital templating system to measure (1) the positions of the operated hips with respect to the normal, contralateral hips (the centre of rotation of the socket, the height of the centre of rotation from the teardrop, and lateralisation of the centre of rotation from the teardrop) and (2) the uniformity and width of the cement mantle in the 3 DeLee Charnley acetabular zones, and the number of radiolucencies in these zones. RESULTS: The study group showed improved radiological parameters and were closer to the anatomic centre of rotation both vertically (1.5 vs. 3.7 mm, p<0.001) and horizontally (1.8 vs. 4.4 mm, p<0.001) and had consistently thicker and more uniform cement mantles (p<0.001). There were 2 radiolucent lines in the control group but none in the study group. CONCLUSION: The Rim Cutter resulted in more accurate placement of the centre of rotation of a cemented prosthetic socket, and produced a thicker, more congruent cement mantle with fewer radiolucent lines.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Cementation/instrumentation , Cementation/methods , Acetabulum/diagnostic imaging , Cementation/trends , Humans , Prosthesis Failure , Radiography
19.
Cochrane Database Syst Rev ; (1): CD001353, 2009 Jan 21.
Article in English | MEDLINE | ID: mdl-19160196

ABSTRACT

BACKGROUND: Injuries to the knee menisci are common and operations to treat them are among the most common procedures performed by orthopaedic surgeons. OBJECTIVES: To evaluate the effects of common surgical interventions in the treatment of meniscal injuries of the knee. The four comparisons under test were: a) surgery versus conservative treatment, b) partial versus total meniscectomy, c) excision versus repair of meniscal tears, d) surgical access, in particular arthroscopic versus open. SEARCH STRATEGY: We searched the Cochrane Bone, Joint and Muscle Trauma Group specialised register (March 2001), MEDLINE (1966 -1998) and bibliographies of published papers. SELECTION CRITERIA: All randomised and quasi-randomised trials which involved the above four comparisons or which compared other surgical interventions for the treatment of meniscal injury. DATA COLLECTION AND ANALYSIS: Trial inclusion was agreed by both reviewers who independently assessed trial quality, by use of a 12 item scale, and extracted data. Where possible and appropriate, data were presented graphically. MAIN RESULTS: Three trials, involving 260 patients, which addressed two (partial versus total meniscectomy; surgical access) comparisons were included.Partial meniscectomy may allow a slightly enhanced recovery rate as well as a potentially improved overall functional outcome including better knee stability in the long term. It is probably associated with a shorter operating time with no apparent difference in early complications or re-operation between partial and total meniscectomy. The long term advantage of partial meniscectomy indicated by the absence of symptoms (symptoms or further operation at six years or over: 14/98 versus 22/94; Peto odds ratio 0.55, 95% confidence interval 0.27 to 1.14) or radiographical outcome was not established.The results available from the only trial comparing arthroscopic with open meniscectomy were very limited in terms of patient numbers and length of follow-up. However it is likely that partial meniscectomy via arthroscopy is associated with shorter operating times and a quicker recovery. AUTHORS' CONCLUSIONS: The lack of randomised trials means that no conclusions can be drawn on the issue of surgical versus non-surgical treatment of meniscal injuries, nor meniscal tear repair versus excision.In randomised trials so far reported, there is no evidence of difference in radiological or long term clinical outcomes between arthroscopic and open meniscal surgery, or between total and partial meniscectomy. Partial meniscectomy seems preferable to the total removal of the meniscus in terms of recovery and overall functional outcome in the short term.


Subject(s)
Menisci, Tibial/surgery , Tibial Meniscus Injuries , Adult , Humans , Knee Injuries/surgery
20.
Instr Course Lect ; 53: 99-110, 2004.
Article in English | MEDLINE | ID: mdl-15116604

ABSTRACT

Fractures of the femur after total hip replacement are an increasingly common and technically challenging problem. The results of nonsurgical treatment are poor. When the general condition of the patient allows, these injuries should be treated surgically. Several surgical treatments can be used to treat these fractures, and classification of the fracture assists the surgeon in the choice of procedure. Over the past decade, cable plate fixation systems and onlay strut allografts have become two of the most commonly used methods of fixation for fractures associated with hip prostheses. The ideal method of fixation is yet to be determined. However, laboratory studies have shown that dual fixation using either a lateral plate and anterior strut graft or two strut grafts produces the strongest construct. Cables rather than smooth wires should be used for fixation, and fixation strength increases with the number of cables used. The use of screws proximally produces a strong fixation but there are theoretical disadvantages to using screws around a femoral implant. Clinical data show high rates of fracture union using cable plate fixation, cortical onlay allograft fixation, and combined fixation methods for fractures that occur around well-fixed implants. Results have been less encouraging when these techniques have been used to fix fractures around prostheses that are either loose or malaligned; such fractures are better managed by revision of the femoral component to a long-stemmed device. Care should also be taken when there has been previous periosteal stripping of the femur because this may predispose to fracture nonunion. Periprosthetic fractures of the femur are a complex surgical problem and require specialized training in a range of surgical techniques.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Plates , Bone Transplantation/methods , Femoral Fractures/surgery , Fracture Fixation, Internal/methods , Postoperative Complications/surgery , Equipment Design , Humans , Internal Fixators , Treatment Outcome