Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Biosens Bioelectron ; 126: 725-733, 2019 Feb 01.
Article in English | MEDLINE | ID: mdl-30553102

ABSTRACT

Microfluidic polymerase chain reaction (PCR) has been of great interest owing to its ability to perform rapid and specific nucleic acid amplification and analysis on small volumes of samples. One of the major drawbacks of microfluidic PCR is bubble generation and reagent evaporation, which can cause malfunctions. Here, through theoretical modeling and characterization of bubble behavior, we propose a bubble-free microfluidic PCR device via controlled fluid transfer. Our approach exploits a thin impermeable polyethylene (PE) top layer that minimizes the generation of bubbles by inhibiting mass transport along a vertical direction. Simulation results demonstrate that a calculated mass flow difference of approximately 370% can be obtained by utilizing an impermeable membrane as the vertical barrier layer. To demonstrate proof-of-concept, two nanoporous polymeric materials, poly(dimethylsiloxane) (PDMS) and PE, were used for stand-alone self-powered sample loading (approximately 70 s) and for use as a vertical barrier layer, respectively. Consequently, we demonstrate successful amplification of the cMET gene, a nucleic acid (NA) biomarker for lung cancer, and complete an ultrafast PCR test in less than 3 min using a high powered Peltier-based thermal cycler under bubble-free conditions. This approach will result in a new paradigm for ultrafast molecular diagnosis and can facilitate NA-based nearly instantaneous diagnostics for point-of-care testing and for personalized and preventive medicine.


Subject(s)
Biosensing Techniques , Lung Neoplasms/diagnosis , Microfluidic Analytical Techniques , Proto-Oncogene Proteins c-met/isolation & purification , Biomarkers, Tumor/genetics , Biomarkers, Tumor/isolation & purification , Computer Simulation , Humans , Lung Neoplasms/genetics , Models, Theoretical , Polyethylene/chemistry , Polymers/chemistry , Proto-Oncogene Proteins c-met/genetics
2.
Proc Natl Acad Sci U S A ; 114(51): 13465-13470, 2017 12 19.
Article in English | MEDLINE | ID: mdl-29187529

ABSTRACT

Cells that proliferate within a confined environment build up mechanical compressive stress. For example, mechanical pressure emerges in the naturally space-limited tumor environment. However, little is known about how cells sense and respond to mechanical compression. We developed microfluidic bioreactors to enable the investigation of the effects of compressive stress on the growth of the genetically tractable model organism Saccharomyces cerevisiae We used this system to determine that compressive stress is partly sensed through a module consisting of the mucin Msb2 and the cell wall protein Sho1, which act together as a sensor module in one of the two major osmosensing pathways in budding yeast. This signal is transmitted via the MAPKKK kinase Ste11. Thus, we term this mechanosensitive pathway the "SMuSh" pathway, for Ste11 through Mucin/Sho1 pathway. The SMuSh pathway delays cells in the G1 phase of the cell cycle and improves cell survival in response to growth-induced pressure. We also found that the cell wall integrity (CWI) pathway contributes to the response to mechanical compressive stress. These latter results are confirmed in complimentary experiments in Mishra et al. [Mishra R, et al. (2017) Proc Natl Acad Sci USA, 10.1073/pnas.1709079114]. When both the SMuSh and the CWI pathways are deleted, cells fail to adapt to compressive stress, and all cells lyse at relatively low pressure when grown in confinement. Thus, we define a network that is essential for cell survival during growth under pressure. We term this mechanosensory system the SCWISh (survival through the CWI and SMuSh) network.


Subject(s)
Cell Wall/metabolism , Intracellular Signaling Peptides and Proteins/metabolism , Membrane Proteins/metabolism , Saccharomyces cerevisiae Proteins/metabolism , Stress, Mechanical , Actin Cytoskeleton/metabolism , Cell Cycle , Intracellular Signaling Peptides and Proteins/genetics , MAP Kinase Kinase Kinases/genetics , MAP Kinase Kinase Kinases/metabolism , Mechanotransduction, Cellular , Membrane Proteins/genetics , Saccharomyces cerevisiae/genetics , Saccharomyces cerevisiae/growth & development , Saccharomyces cerevisiae/metabolism , Saccharomyces cerevisiae Proteins/genetics
3.
Adv Healthc Mater ; 5(1): 167-74, 2016 Jan 07.
Article in English | MEDLINE | ID: mdl-26592501

ABSTRACT

Recent outbreaks of deadly infectious diseases, such as Ebola and Middle East respiratory syndrome coronavirus, have motivated the research for accurate, rapid diagnostics that can be administered at the point of care. Nucleic acid biomarkers for these diseases can be amplified and quantified via polymerase chain reaction (PCR). In order to solve the problems of conventional PCR--speed, uniform heating and cooling, and massive metal heating blocks--an innovative optofluidic cavity PCR method using light-emitting diodes (LEDs) is accomplished. Using this device, 30 thermal cycles between 94 °C and 68 °C can be accomplished in 4 min for 1.3 µL (10 min for 10 µL). Simulation results show that temperature differences across the 750 µm thick cavity are less than 2 °C and 0.2 °C, respectively, at 94 °C and 68 °C. Nucleic acid concentrations as low as 10(-8) ng µL(-1) (2 DNA copies per µL) can be amplified with 40 PCR thermal cycles. This simple, ultrafast, precise, robust, and low-cost optofluidic cavity PCR is favorable for advanced molecular diagnostics and precision medicine. It is especially important for the development of lightweight, point-of-care devices for use in both developing and developed countries.


Subject(s)
Optical Phenomena , Polymerase Chain Reaction/methods , Computer Simulation , Electronics , Gold/chemistry , Humans , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL