Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 94(1): 014502, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36725558

ABSTRACT

Advanced Laser Interferometer Gravitational-wave Observatory (LIGO A+) is a major upgrade to LIGO-the Laser Interferometer Gravitational-wave Observatory. For the A+ project, we have developed, produced, and characterized sensors and electronics to interrogate new optical suspensions designed to isolate optics from vibrations. The central element is a displacement sensor with an integrated electromagnetic actuator known as a BOSEM (Birmingham Optical Sensor and ElectroMagnetic actuator) and its readout and drive electronics required to integrate them into LIGO's control and data system. In this paper, we report on the improvements to the sensors and the testing procedures undertaken to meet the enhanced performance requirements set out by the A+ upgrade to the detectors. The best devices reach a noise level of 4.5 ×10-11m/Hz at a measurement frequency of 1 Hz, an improvement of 6.7 times over standard devices.

2.
Phys Rev Lett ; 126(13): 131103, 2021 Apr 02.
Article in English | MEDLINE | ID: mdl-33861094

ABSTRACT

We report on the first subpicometer interferometer flown in space. It was part of ESA's Laser Interferometer Space Antenna (LISA) Pathfinder mission and performed the fundamental measurement of the positional and angular motion of two free-falling test masses. The interferometer worked immediately, stably, and reliably from switch on until the end of the mission with exceptionally low residual noise of 32.0_{-1.7}^{+2.4} fm/sqrt[Hz], significantly better than required. We present an upper limit for the sensor performance at millihertz frequencies and a model for the measured sensitivity above 200 mHz.

3.
Rev Sci Instrum ; 91(4): 045003, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32357757

ABSTRACT

The Laser Interferometer Space Antenna Pathfinder (LPF) main observable, labeled Δg, is the differential force per unit mass acting on the two test masses under free fall conditions after the contribution of all non-gravitational forces has been compensated. At low frequencies, the differential force is compensated by an applied electrostatic actuation force, which then must be subtracted from the measured acceleration to obtain Δg. Any inaccuracy in the actuation force contaminates the residual acceleration. This study investigates the accuracy of the electrostatic actuation system and its impact on the LPF main observable. It is shown that the inaccuracy is mainly caused by the rounding errors in the waveform processing and also by the random error caused by the analog to digital converter random noise in the control loop. Both errors are one order of magnitude smaller than the resolution of the commanded voltages. We developed a simulator based on the LPF design to compute the close-to-reality actuation voltages and, consequently, the resulting actuation forces. The simulator is applied during post-processing the LPF data.

4.
Phys Rev Lett ; 123(11): 111101, 2019 Sep 13.
Article in English | MEDLINE | ID: mdl-31573236

ABSTRACT

We report on the results of the LISA Pathfinder (LPF) free-fall mode experiment, in which the control force needed to compensate the quasistatic differential force acting on two test masses is applied intermittently as a series of "impulse" forces lasting a few seconds and separated by roughly 350 s periods of true free fall. This represents an alternative to the normal LPF mode of operation in which this balancing force is applied continuously, with the advantage that the acceleration noise during free fall is measured in the absence of the actuation force, thus eliminating associated noise and force calibration errors. The differential acceleration noise measurement presented here with the free-fall mode agrees with noise measured with the continuous actuation scheme, representing an important and independent confirmation of the LPF result. An additional measurement with larger actuation forces also shows that the technique can be used to eliminate actuation noise when this is a dominant factor.

5.
Phys Rev Lett ; 120(6): 061101, 2018 Feb 09.
Article in English | MEDLINE | ID: mdl-29481269

ABSTRACT

In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20 µHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74±0.05) fm s^{-2}/sqrt[Hz] above 2 mHz and (6±1)×10 fm s^{-2}/sqrt[Hz] at 20 µHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency.

6.
Phys Rev Lett ; 116(23): 231101, 2016 Jun 10.
Article in English | MEDLINE | ID: mdl-27341221

ABSTRACT

We report the first results of the LISA Pathfinder in-flight experiment. The results demonstrate that two free-falling reference test masses, such as those needed for a space-based gravitational wave observatory like LISA, can be put in free fall with a relative acceleration noise with a square root of the power spectral density of 5.2±0.1 fm s^{-2}/sqrt[Hz], or (0.54±0.01)×10^{-15} g/sqrt[Hz], with g the standard gravity, for frequencies between 0.7 and 20 mHz. This value is lower than the LISA Pathfinder requirement by more than a factor 5 and within a factor 1.25 of the requirement for the LISA mission, and is compatible with Brownian noise from viscous damping due to the residual gas surrounding the test masses. Above 60 mHz the acceleration noise is dominated by interferometer displacement readout noise at a level of (34.8±0.3) fm/sqrt[Hz], about 2 orders of magnitude better than requirements. At f≤0.5 mHz we observe a low-frequency tail that stays below 12 fm s^{-2}/sqrt[Hz] down to 0.1 mHz. This performance would allow for a space-based gravitational wave observatory with a sensitivity close to what was originally foreseen for LISA.

7.
J Immunol ; 139(4): 991-7, 1987 Aug 15.
Article in English | MEDLINE | ID: mdl-2956329

ABSTRACT

We have examined the effect of exogenous IL 2 on cell surface antigen expression in LPS/dextran sulfate-activated murine B cells with the use of a panel of fluorescein-conjugated lectins. Elevated binding of the lectins PNA and SBA to activated B cells was found to be mediated by IL 2-containing supernatants from stimulated EL4 cells as well as by recombinant IL 2. These lectins have specificity for terminal beta-(1-3)-N-acetylgalactosaminyl residues; thus, the quantity or accessibility of these moieties is mediated by IL 2 in activated B lymphocytes. PNA binding in all strains tested, regardless of MHC or background genes, was found to be elevated fivefold to 15-fold by exogenous IL 2. To observe this effect, IL 2 must be added during the first 24 hr of culture. Based on anti-Thy-1 + complement depletion studies, T cells were not required, suggesting a direct effect of IL 2 on B cells. The glycoprotein responsible for this elevated binding of PNA has an Mr of approximately 220K and by immunodepletion was shown to belong to the T200 (Ly-5) family of cell surface antigens. These data demonstrate that exogenous IL 2 can mediate alterations in T200 expression on activated B cells that may be related to IL 2-driven modulation of B cell proliferation and/or differentiation.


Subject(s)
Antigens, Surface/immunology , B-Lymphocytes/immunology , Histocompatibility Antigens/immunology , Interleukin-2/physiology , Lymphocyte Activation , Animals , Antigens, Differentiation, B-Lymphocyte , Interleukin-2/administration & dosage , Lectins , Leukocyte Common Antigens , Mice , Mice, Inbred Strains/immunology , Peanut Agglutinin , Receptors, Mitogen/physiology , Recombinant Proteins/administration & dosage , T-Lymphocytes/immunology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...