Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Echocardiography ; 23(9): 763-70, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16999695

ABSTRACT

BACKGROUND: Transcatheter Amplatzer septal occluder (ASO) device closure of atrial septal defects (ASDs) has traditionally been guided by two-dimensional transesophageal echocardiography (2D-TEE) and intracardiac echocardiography (ICE) modalities. Real time three-dimensional transthoracic echocardiography (RT3D-TTE) provides rotating images to define ASD and adjacent structures with potential as an alternative to 2D-TEE or ICE for guiding the device closure of ASD. Our aim was to assess the feasibility and effectiveness of RT3D-TTE in parasternal four-chamber views to guide ASO device closure of ASD. METHODS AND RESULTS: From July 2004 to August 2005, 59 patients underwent transcatheter ASO device closure of ASD. The first 30 patients underwent 2D-TEE guidance under general anesthesia and the remaining 29 patients underwent RT3D-TTE guidance with local anesthesia. All interventions were successfully completed without complications. The clinical characteristics and transcatheter closure variables of RT3D-TTE and 2D-TEE were compared. Echocardiographic visualization of ASD and ASO deployment was found to be adequate when using either methods. Catheterization laboratory time (39.1 +/- 5.4 vs 78.8 +/- 14.1 minutes, P < 0.001) and interventional procedure length (7.6 +/- 4.2 vs 15.3 +/- 2.9 minutes, P < 0.001) were shortened by using RT3D-TTE as compared with 2DE-TEE. There was no difference in the rate of closure following either method, assessed after a 6-month follow-up. The maximal diameter measured by RT3D-TTE and 2D-TEE was correlated well with a balloon-stretched ASD size (y = 0.985x + 0.628, r = 0.924 vs y = 0.93x + 2.08, r = 0.885, respectively). CONCLUSION: RT3D-TTE may be a feasible, safe, and effective alternative to the standard practice of using 2D-TEE to guide ASO deployment.


Subject(s)
Balloon Occlusion/instrumentation , Cardiac Catheterization , Computer Systems , Echocardiography, Three-Dimensional , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy , Adolescent , Child , Child, Preschool , Feasibility Studies , Female , Follow-Up Studies , Humans , Length of Stay , Male , Observer Variation , Postoperative Complications/diagnostic imaging , Postoperative Complications/etiology , Prosthesis Design , Research Design , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...